QUANTITATIVE PARAMETERS OF HIGH-FRAME-RATE STRAIN IN PATIENTS WITH ECHOCARDIOGRAPHICALLY NORMAL FUNCTION

被引:8
|
作者
Andersen, Martin, V [1 ]
Moore, Cooper [2 ]
Sogaard, Peter [3 ]
Friedman, Daniel [4 ]
Atwater, Brett D. [4 ]
Arges, Kristine [4 ]
LeFevre, Melissa [4 ]
Struijk, Johannes J. [1 ]
Kisslo, Joseph [4 ]
Schmidt, Samuel E. [1 ]
von Ramm, Olaf T. [2 ]
机构
[1] Aalborg Univ, Aalborg, Denmark
[2] Duke Univ, Durham, NC USA
[3] Aalborg Univ Hosp, Dept Cardiol, Aalborg, Denmark
[4] Duke Univ Hosp, Durham, NC USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2019年 / 45卷 / 05期
关键词
Deformation imaging; Strain; Algorithm; Speckle tracking; Ultrasound; Echocardiography; High frame rate; Feature tracking; ELECTROMECHANICAL WAVE; TISSUE DOPPLER; ACTIVATION;
D O I
10.1016/j.ultrasmedbio.2018.11.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Recently, we developed a high-frame-rate echocardiographic imaging system capable of acquiring images at rates up to 2500 per second. High imaging rates were used to quantify longitudinal strain parameters in patients with echocardiographically normal function. These data can serve as a baseline for comparing strain parameters in disease states. The derived timing data also reveal the propagation of mechanical events in the left ventricle throughout the cardiac cycle. High-frame-rate echocardiographic images were acquired from 17 patients in the apical four-chamber view using Duke University's phased array ultrasound system, T5. B-Mode images were acquired at 500-1000 images per second by employing 16:1 or 32:1 parallel processing in receive, a scan depth <= 14 cm and an 80 degrees field of view with a 3.5-MegaHertZ (MHz), 96-element linear array. The images were analyzed using a speckle tracking algorithm tailored for high-frame-rate echocardiographic images developed at Aalborg and Duke University. Four specific mechanical events were defined using strain curves from six regions along the myocardial contour of the left ventricle. The strain curves measure the local deformation events of the myocardium and are independent of the overall cardiac motion. We observed statistically significant differences in the temporal sequence among different myocardial segments for the first mechanical event described, myocardial tissue shortening onset (p < 0.01). We found that the spatial origin of tissue shortening was located near the middle of the interventricular septum in patients with echocardiographically normal function. The quantitative parameters defined here, based on high-speed strain measurements in patients with echocardiographically normal function, can serve as a means of assessing degree of contractile abnormality in the myocardium and enable the identification of contraction propagation. The relative timing pattern among specific events with respect to the Q wave may become an important new metric in assessing cardiac function and may, in turn, improve diagnosis and prognosis. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1197 / 1207
页数:11
相关论文
共 50 条
  • [21] HIGH-FRAME-RATE SPECKLE TRACKING FOR ECHOCARDIOGRAPHIC STRESS TESTING
    Orlowska, Marta
    Bezy, Stephanie
    Ramalli, Alessandro
    Voigt, Jens -Uwe
    D'Hooge, Jan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (08): : 1644 - 1651
  • [22] Quantitative evaluation using carotid ultrasonography-based high-frame-rate vector flow imaging in patients with low carotid stenosis
    Chen, Jing
    Zhang, Luni
    Gu, Shiyao
    Jia, Caixia
    Wu, Rong
    BRITISH JOURNAL OF RADIOLOGY, 2024, 97 (1160): : 1476 - 1482
  • [23] Optimization of Microbubble Concentration and Acoustic Pressure for Left Ventricular High-Frame-Rate EchoPIV in Patients
    Voorneveld, Jason
    Keijzer, Lana B. H.
    Strachinaru, Mihai
    Bowen, Daniel J.
    Mutluer, Ferit Onur
    van der Steen, Antonius F. W.
    Ten Cate, Folkert J.
    de Jong, Nico
    Vos, Hendrik J.
    van den Bosch, Annemien E.
    Bosch, Johan G.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2432 - 2443
  • [24] Echo speckle imaging of blood particles with high-frame-rate echocardiography
    Takahashi, Hiroki
    Hasegawa, Hideyuki
    Kanai, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [25] Frequency-Domain-Based Strain Estimation and High-Frame-Rate Imaging for Quasi-Static Elastography
    Ramalli, Alessandro
    Basset, Olivier
    Cachard, Christian
    Boni, Enrico
    Tortoli, Piero
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (04) : 817 - 824
  • [26] Perceptual Quality Driven Frame-Rate Selection (PQD-FRS) for High-Frame-Rate Video
    Huang, Qin
    Jeong, Se Yoon
    Yang, Shanglin
    Zhang, Dichen
    Hu, Sudeng
    Kim, Hui Yong
    Choi, Jin Soo
    Kuo, C. -C. Jay
    IEEE TRANSACTIONS ON BROADCASTING, 2016, 62 (03) : 640 - 653
  • [27] High-Resolution and High-Frame-Rate Image Estimation with Heterogeneous Cameras
    Nagai, Tomoaki
    Namiki, Akio
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 1329 - 1334
  • [28] High-frame-rate reconfigurable diffractive neural network based on superpixels
    Qu, Yuan
    Lian, Hengyu
    Ding, Chunxu
    Liu, Huazhen
    Liu, Linxian
    Yang, Jiamiao
    OPTICS LETTERS, 2023, 48 (19) : 5025 - 5028
  • [29] The Analysis of Eye Blinking Pattern Using High-Frame-Rate Camera
    Lee, Woon-Hee
    Seo, Jong-Mo
    Hwang, Jeong-Min
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1509 - 1512
  • [30] Improving quality of high-frame-rate imaging with coherent and incoherent processing
    Liu, Jian-yu
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,