Validation of a live animal model for training in endoscopic hemostasis of upper gastrointestinal bleeding ulcers

被引:22
作者
Camus, M. [1 ,2 ,3 ]
Marteau, P. [1 ,2 ,4 ]
Pocard, M. [3 ,5 ]
Sollier, C. Bal Dit [6 ,7 ]
Lavergne-Slove, A. [8 ]
Thibault, A. [1 ,2 ,6 ,7 ]
Lecleire, S. [9 ]
Vienne, A. [10 ]
Coffin, B. [11 ]
Drouet, L. [6 ,7 ]
Dray, X. [1 ,2 ,3 ,4 ,12 ]
机构
[1] Univ Paris 07, Lariboisiere Hosp, APHP, F-75010 Paris, France
[2] Univ Paris 07, Lariboisiere Hosp, APHP, Sch Surg, F-75010 Paris, France
[3] INSERM, U965, Paris, France
[4] Inserm CRB3, Innovat & Rech Endoscopie & Chirurg ITEC, Paris, France
[5] Univ Paris 07, Lariboisiere Hosp, APHP, Dept Surg, F-75010 Paris, France
[6] Univ Paris 07, Lariboisiere Hosp, APHP, Lab Hematol Hemostasis & Thrombosis, F-75010 Paris, France
[7] Inst Vaisseaux & Sang, Paris, France
[8] Univ Paris 07, Lariboisiere Hosp, APHP, Dept Pathol, F-75010 Paris, France
[9] Rouen Univ Hosp, Dept Gastroenterol & Hepatol, Rouen, France
[10] Univ Paris 05, Cochin Hosp, APHP, Dept Gastroenterol, Paris, France
[11] Univ Paris 07, Louis Mourier Hosp, APHP, Dept Gastroenterol, F-75010 Paris, France
[12] Johns Hopkins Univ, Sch Med, Dept Med, Div Gastroenterol, Baltimore, MD 21205 USA
关键词
ERLANGEN ACTIVE SIMULATOR; PEPTIC-ULCER; INTERVENTIONAL ENDOSCOPY; PORCINE MODEL; COAGULATION; EPIDEMIOLOGY; FEASIBILITY; HEMORRHAGE; DISEASE; DEVICES;
D O I
10.1055/s-0032-1326483
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: The management of upper gastrointestinal bleeding requires training of the endoscopist. We aimed to validate a live animal model of bleeding ulcers for training in endoscopic hemostasis. Materials and methods: Bleeding ulcers were created by repeated grasp-and-snare gastric mucosectomies in pigs rendered "bleeders" by preadministration of clopidogrel, aspirin, and unfractionated heparin. The feasibility and reproducibility of the model (proportion of bleeding ulcers, number of ulcers per animal, and time needed to produce a bleeding ulcer) were prospectively evaluated in six animals. Ten endoscopic experts assessed the similarity of this pig model to human bleeding ulcers (four-point Likert scale). The training capabilities of the model for hemostatic techniques (needle injection, bipolar electrocoagulation, and hemoclipping) were evaluated in 46 fellows (four-point Likert scale). Results: A total of 53 gastric ulcers were created in 6 animals (8.8 +/- 1.5 ulcers/animal). Successful active ulcer bleeding (Forrest Ib) was achieved in 96.2% of cases. Bleeding was moderate to abundant in 79% of cases. Ulcerations consistently reached the submucosal layer. The mean (+/- SD) time taken to create a bleeding ulcer was 3.8 +/- 0.6 minutes. Endoscopic experts assessed the realism of the ulcers and bleeding at 3.2 +/- 0.7 and 3.6 +/- 0.7 respectively on a four-point Likert scale. The training significantly improved the endoscopic skills of the 46 fellows (P < 0.0001) in all hemostatic techniques. Conclusions: The live porcine model of bleeding ulcers was demonstrated to be realistic, reproducible, feasible, time efficient, and easy to perform. It was favorably assessed as an excellent model for training in endoscopic treatment of bleeding ulcers.
引用
收藏
页码:451 / 457
页数:7
相关论文
共 27 条
  • [1] BOWIE EJW, 1973, AM J VET RES, V34, P1405
  • [2] Computer simulators: The present and near future of training in digestive endoscopy
    Cantu, Paolo
    Penagini, Roberto
    [J]. DIGESTIVE AND LIVER DISEASE, 2012, 44 (02) : 106 - 110
  • [3] Creation of an effective and reproducible nonsurvival porcine model that simulates actively bleeding peptic ulcers
    Chen, Victor K.
    Marks, Jeffrey M.
    Wong, Richard C. K.
    McGee, Michael F.
    Faulx, Ashley L.
    Isenberg, Gerard A.
    Schomisc, Steven J.
    Deng, Cheri X.
    Ponsky, Jeffrey L.
    Chak, Amitabh
    [J]. GASTROINTESTINAL ENDOSCOPY, 2008, 68 (03) : 548 - 553
  • [4] Endoscopic plication of massively bleeding peptic ulcer by using the Eagle Claw VII device: a feasibility study in a porcine model
    Chiu, PWY
    Hu, B
    Lau, JYW
    Sun, LCL
    Sung, JJY
    Chung, SSC
    [J]. GASTROINTESTINAL ENDOSCOPY, 2006, 63 (04) : 681 - 685
  • [5] DENNIS MB, 1981, GASTROENTEROLOGY, V80, P1522
  • [6] Endoscopic simulators
    Desilets, David J.
    Banerjee, Subhas
    Barth, Bradley A.
    Kaul, Vivek
    Kethu, Sripathi R.
    Pedrosa, Marcos C.
    Pfau, Patrick R.
    Tokar, Jeffrey L.
    Varadarajulu, Shyam
    Wang, Amy
    Song, Louis-Michel Wong Kee
    Rodriguez, Sarah A.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2011, 73 (05) : 861 - 867
  • [7] Di Fiore F, 2005, EUR J GASTROEN HEPAT, V17, P641, DOI 10.1097/00042737-200506000-00008
  • [8] Endoscopic full-thickness resection of gastric tumors using a novel grasp-and-snare technique: feasibility in ex vivo and in vivo porcine models
    Elmunzer, B. J.
    Trunzo, J. A.
    Marks, J. M.
    Poulose, B. K.
    Chak, A.
    Schomisch, S. J.
    Bailey, J. J.
    Ponsky, J. L.
    [J]. ENDOSCOPY, 2008, 40 (11) : 931 - 935
  • [9] Systematic Review of the Predictors of Recurrent Hemorrhage After Endoscopic Hemostatic Therapy for Bleeding Peptic Ulcers
    Elmunzer, B. Joseph
    Young, Scott D.
    Inadomi, John M.
    Schoenfeld, Philip
    Laine, Loren
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (10) : 2625 - 2632
  • [10] FORREST JAH, 1974, LANCET, V2, P394