Fast trace determination of nine odorant and estrogenic chloro- and bromo-phenolic compounds in real water samples through automated solid-phase extraction coupled with liquid chromatography tandem mass spectrometry
被引:32
作者:
Yuan, Su-fen
[1
]
Liu, Ze-hua
[1
,2
,3
,4
]
Lian, Hai-xian
[5
,6
]
Yang, Chuang-tao
[5
,6
]
Lin, Qing
[5
,6
]
Yin, Hua
[1
]
Lin, Zhang
[1
]
Dang, Zhi
[1
]
机构:
[1] South China Univ Technol, Sch Environm & Energy, Guangzhou 510006, Guangdong, Peoples R China
[2] Minist Educ, Key Lab Pollut Control & Ecosyst Restorat Ind Clu, Guangzhou 510006, Guangdong, Peoples R China
[3] Guangdong Environm Protect Key Lab Solid Waste Tr, Guangzhou 510006, Guangdong, Peoples R China
[4] South China Univ Technol, Guangdong Prov Engn & Technol Res Ctr Environm Ri, Guangzhou 510006, Guangdong, Peoples R China
[5] Guangdong Yue Gang Water Supply Co LTD, Ctr Water Environm Monitoring, Shenzhen 518021, Guangdong, Peoples R China
[6] Guandong GDH Water Co LTD, Dept Water Technol Res & Dev, Shenzhen 518021, Guangdong, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Trace determination;
SPE;
LC-MS/MS;
Odorant;
Estrogenic chlorophenols;
Bromophenols;
Surface water;
Tap water;
MUNICIPAL WASTE-WATER;
PERSONAL CARE PRODUCTS;
NATURAL FREE ESTROGENS;
PURGE-AND-TRAP;
GAS-CHROMATOGRAPHY;
ARTIFICIAL SWEETENERS;
FLAME RETARDANTS;
EXCRETION RATES;
GRAPHENE OXIDE;
DRINKING-WATER;
D O I:
10.1007/s11356-017-0816-2
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
A fast and reliable method was developed for simultaneous trace determination of nine odorous and estrogenic chloro- and bromo-phenolic compounds (CPs and BPs) in water samples using solid-phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). For sample preparation, the extraction efficiencies of two widely applied cartridges Oasis HLB and Sep-Pak C18 were compared, and the Oasis HLB cartridge showed much better extraction performance; pH of water sample also plays important role on extraction, and pH = 2-3 was found to be most appropriate. For separation of the target compounds, small addition of ammonium hydroxide can obviously improve the detection sensitivity, and the optimized addition concentration was determined as 0.2%. The developed efficient method was validated and showed excellent linearity (R-2 > 0.995), low limit of detection (LOD, 1.9-6.2 ng/L), and good recovery efficiencies of 57-95% in surface and tap water with low relative standard deviation (RSD, 1.3-17.4%). The developed method was finally applied to one tap and one surface water samples and most of these nine targets were detected, but all of them were below their odor thresholds, and their estrogen equivalent (EEQ) were also very low.