Arbitrary magnetic field gradient waveform correction using an impulse response based pre-equalization technique

被引:35
作者
Goora, Frederic G. [1 ,2 ]
Colpitts, Bruce G. [1 ]
Balcom, Bruce J. [2 ]
机构
[1] Univ New Brunswick, Dept Elect & Comp Engn, Fredericton, NB E3B 5A3, Canada
[2] Univ New Brunswick, Dept Phys, MRI Ctr, Fredericton, NB E3B 5A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Magnetic field gradient waveform correction; Impulse response; Pre-equalization; Optimal gradient waveforms; Eddy currents; EDDY-CURRENT COMPENSATION; K-SPACE TRAJECTORIES; SYSTEM CHARACTERIZATION; NMR; MRI; SPECTROSCOPY; SPRITE; SENSITIVITY; COILS;
D O I
10.1016/j.jmr.2013.11.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The time-varying magnetic fields used in magnetic resonance applications result in the induction of eddy currents on conductive structures in the vicinity of both the sample under investigation and the gradient coils. These eddy currents typically result in undesired degradations of image quality for MRI applications. Their ubiquitous nature has resulted in the development of various approaches to characterize and minimize their impact on image quality. This paper outlines a method that utilizes the magnetic field gradient waveform monitor method to directly measure the temporal evolution of the magnetic field gradient from a step-like input function and extracts the system impulse response. With the basic assumption that the gradient system is sufficiently linear and time invariant to permit system theory analysis, the impulse response is used to determine a pre-equalized (optimized) input waveform that provides a desired gradient response at the output of the system. An algorithm has been developed that calculates a pre-equalized waveform that may be accurately reproduced by the amplifier (is physically realizable) and accounts for system limitations including system bandwidth, amplifier slew rate capabilities, and noise inherent in the initial measurement. Significant improvements in magnetic field gradient waveform fidelity after pre-equalization have been realized and are summarized. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:70 / 76
页数:7
相关论文
共 50 条
[1]   Simple method for MR gradient system characterization and k-space trajectory estimation [J].
Addy, Nii Okai ;
Wu, Holden H. ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) :120-129
[2]  
[Anonymous], 2004, HDB MRI PULSE SEQUEN, DOI 10.1016/B978-0-12-092861-3.X5000-6
[3]   Single-point ramped imaging with T-1 enhancement (SPRITE) [J].
Balcom, BJ ;
MacGregor, RP ;
Beyea, SD ;
Green, DP ;
Armstrong, RL ;
Bremner, TW .
JOURNAL OF MAGNETIC RESONANCE SERIES A, 1996, 123 (01) :131-134
[4]   Spatiotemporal magnetic field monitoring for MR [J].
Barmet, Christoph ;
De Zanche, Nicola ;
Pruessmann, Klaas P. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) :187-197
[5]   Determination of pre-emphasis constants for eddy current reduction [J].
Bartusek, K. ;
Kubasek, R. ;
Fiala, P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (10)
[6]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[7]   Dynamic shim updating: A new approach towards optimized whole brain shimming [J].
Blamire, AM ;
Rothman, DL ;
Nixon, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (01) :159-165
[8]   GRADIENT COIL DESIGN USING ACTIVE MAGNETIC SCREENING [J].
BOWTELL, R ;
MANSFIELD, P .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :15-21
[9]  
Bracewell RB, 1965, The Fourier transform and its application
[10]   QUIET GRADIENT COILS - ACTIVE ACOUSTICALLY AND MAGNETICALLY SCREENED DISTRIBUTED TRANSVERSE GRADIENT DESIGNS [J].
CHAPMAN, BLW ;
MANSFIELD, P .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (04) :349-354