UHF Technique for Identification of Partial Discharge in a Composite Insulation Under AC and DC voltages

被引:29
作者
Sarathi, R. [1 ]
Koperundevi, G. [1 ]
机构
[1] Indian Inst Technol, Dept Elect Engn, Madras 600036, Tamil Nadu, India
关键词
Partial discharges; UHF sensors; oil insulation; power transformer insulation;
D O I
10.1109/TDEI.2008.4712677
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
DC power transmission is gaining considerable importance and converter transformers form an important component in it. An insulation of these transformers is stressed by both ac and de voltages. Particle contamination is one of the major problems in insulation structures as it generates partial discharges (PD). If a particle is moving between the ground electrode and barrier, the magnitude of partial discharges formed is less compared to that of its movement between two metal electrodes. On the other hand, when the particle is lying over the barrier insulation material, it does not lead to any partial discharge activities as observed under ac/dc voltages. Broadband measurement of UHF signals produced by partial discharges due to particle movement in transformer oil under dc voltages, at high applied electric fields, indicates that the frequency content of the signal lies in the entire UHF range of 300 MHz - 3GHz. Narrow band measurements of UHF signal due to PD formed by particle movement, at 1GHz, indicates that, in the presence of barrier, an increase in applied voltage results in increase in number of partial discharge pulses. This phenomenon occurs in converse in oil gap without any barrier. In the presence of barrier, the sequential movement of particle occurs and the magnitude of discharges increases with increase in applied voltage, irrespective of polarity of the dc voltage. The number of discharges that occur under ac voltage is high compared to the dc voltages.
引用
收藏
页码:1724 / 1730
页数:7
相关论文
共 27 条
[2]  
[Anonymous], 2000, IECStd.60270
[3]   MICRO-DISCHARGES FROM PARTICLES IN TRANSFORMER OIL [J].
BIRLASEKARAN, S ;
DARVENIZA, M .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1976, 11 (04) :162-163
[4]   THE MOVEMENT OF A CONDUCTING PARTICLE IN TRANSFORMER OIL IN AC FIELDS [J].
BIRLASEKARAN, S .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (01) :9-17
[5]   THE MEASUREMENT OF CHARGE ON SINGLE PARTICLES IN TRANSFORMER OIL [J].
BIRLASEKARAN, S .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1991, 26 (06) :1094-1103
[6]   Particle-initiated breakdown in a quasi-uniform field in transformer oil [J].
Carraz, F ;
Rain, P ;
Tobazeon, R .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1995, 2 (06) :1052-1063
[7]  
Cavallini A, 2005, ICDL: 2005 IEEE International Conference on Dielectric Liquids, P241
[8]   UHF and current pulse measurements of partial discharge activity in mineral oil [J].
Cleary, GP ;
Judd, MD .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2006, 153 (02) :47-54
[9]  
CONVERY AR, 2003, 13 INT S HIGH VOLT E, P321
[10]   Modeling of conductive particle behavior in insulating fluids affected by DC electric fields [J].
Dascalescu, L ;
Mihailescu, M ;
Tobazeon, R .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (01) :66-74