Pulse anodic stripping voltammetric determination of copper with an amoxicillin-nafion modified glassy carbon electrode

被引:12
|
作者
Ramadan, A. A. [1 ]
Mandil, H. [1 ]
Saleh, M. A. [1 ]
机构
[1] Univ Aleppo, Fac Sci, Dept Chem, Aleppo, Syria
关键词
Modified electrode; Pulse anodic stripping voltammetry; Copper determination;
D O I
10.1007/s10800-008-9621-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The analysis of Cu2+by pulse anodic stripping voltammetry using a Nafion-modified glassy Carbon electrode incorporated with Amoxicillin is described. A significant increase in the voltammetric response was achieved at the modified electrode compared to a bare glassy carbon electrode. Cu2+ was accumulated in HAc-NaAc buffer (pH 3.6) at a potential of -0.7 V (vs. Ag/AgCl) for a certain time and then determined by pulse anodic stripping voltammetry. Parameters and conditions, such as the mass of Nafion, the concentration of Amoxicillin, the pH of medium, the accumulation potential, and the accumulation time were optimized. Under the optimum conditions, the calibration curve was linear in the range 8 x 10-10-2 x 10-8 M with a correlation coefficient of 0.9998 and relative standard deviation 4.87% (n = 5). The detection limit was 1.3 x 10-10s M. A study of interfering substances was also performed and the analytical utility of the method was demonstrated by applying to various pharmaceutical products.
引用
收藏
页码:1715 / 1720
页数:6
相关论文
共 50 条
  • [1] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [2] Differential pulse anodic stripping voltammetric determination of traces of copper with a tobramycin-Nafion modified electrode
    Li, NB
    Luo, HQ
    Chen, GN
    ANALYTICAL SCIENCES, 2004, 20 (05) : 825 - 829
  • [3] Differential Pulse Anodic Stripping Voltammetric Determination of Traces of Copper with a Tobramycin-Nafion Modified Electrode
    Nian Bing Li
    Hong Qun Luo
    Guo Nan Chen
    Analytical Sciences, 2004, 20 : 825 - 829
  • [4] Differential pulse adsorptive stripping voltammetric determination of benzocaine and butacaine with Nafion modified glassy carbon electrode
    Reddy, Tukiakula Madhusudana
    Balaji, Kodigutta
    Reddy, Srinivasulu Jayarama Reddy
    CROATICA CHEMICA ACTA, 2006, 79 (02) : 253 - 259
  • [5] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [6] Electrochemistry and Adsorptive Stripping Voltammetric Determination of Amoxicillin on a Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode
    Rezaei, Behzad
    Damiri, Sajjad
    ELECTROANALYSIS, 2009, 21 (14) : 1577 - 1586
  • [7] Anodic Adsorptive Stripping Voltammetric Determination of Rafoxanide on Glassy Carbon Electrode
    Radi, Abd-elgawad
    El-samboskany, Hassan
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2020, 23 (10) : 1002 - 1009
  • [8] Differential pulse anodic stripping voltammetric determination of Pb ion at a montmorillonites/polyaniline nanocomposite modified glassy carbon electrode
    Dong, YongPing
    Ding, Yong
    Zhou, Ying
    Chen, Jun
    Wang, ChengMing
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 206 - 212
  • [9] Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II)
    Cheng, Kuan-Chiao
    Chen, Po-Yu
    ELECTROANALYSIS, 2008, 20 (02) : 207 - 210
  • [10] Anodic stripping voltammetry of arsenic determination with edible mushroom-nafion-modified glassy carbon electrode
    Salinas, Arturo
    Trivino, Juan Jose
    Alvarez-Lueje, Alejandro
    Pizarro, Isabel
    Segura, Rodrigo
    Arancibia, Veronica
    TALANTA, 2024, 277