Analysis of peak asymmetry in chromatography

被引:57
作者
Pápai, Z [1 ]
Pap, TL [1 ]
机构
[1] Univ Veszprem, Inst Analyt Chem, H-8201 Veszprem, Hungary
关键词
peak asymmetry; curve fitting; chemometrics; signal processing;
D O I
10.1016/S0021-9673(02)00121-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The knowledge of the symmetry of chromatographic peaks is extremely important regarding the digital signal processing. The significant deviation of the peak shape from the symmetrical peak makes hardly possible the acquisition of chromatographic signal information. such as the retention time, the peak area, the peak width at half peak height, the peak overlapping, etc. In the literature one can find many methods for the determination of the asymmetry factor. For example it is suitable to calculate the skewness from the third central moment, However in case of noisy baseline the value of the skewness oscillates highly depending on the number of points used for the mathematical calculation. In this work a new method is presented for the determination peak shape asymmetry. We order mathematical function to the chromatographic peaks by fitting, and then symmetrical curve is generated with the same peak maximum position and height. the peak width is fitted. The difference of the two functions is constituted and areas of the data differences are calculated, which are really characteristics of the peak asymmetry. Correlation between the area of the difference signal and the asymmetry factor is established, The method was applied for different types of chromatographic peak shapes and the results were interpreted. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 16 条
[1]   STATISTICAL MOMENT ANALYSIS AND DECONVOLUTION OF OVERLAPPING CHROMATOGRAPHIC PEAKS [J].
CAI, CP ;
WU, NS .
CHROMATOGRAPHIA, 1991, 31 (11-12) :595-599
[2]   Stochastic theory of multiple-site linear adsorption chromatography [J].
Cavazzini, A ;
Remelli, M ;
Dondi, F ;
Felinger, A .
ANALYTICAL CHEMISTRY, 1999, 71 (16) :3453-3462
[3]   ITERATIVE CURVE FITTING OF CHROMATOGRAPHIC PEAKS [J].
CHESLER, SN ;
CRAM, SP .
ANALYTICAL CHEMISTRY, 1973, 45 (08) :1354-1359
[4]   NONLINEAR FITTING METHOD FOR RECORDED CHROMATOGRAPHIC PEAKS [J].
CUSO, E ;
GUARDINO, X ;
RIERA, JM ;
GASSIOT, M .
JOURNAL OF CHROMATOGRAPHY, 1974, 95 (02) :147-157
[5]   THE CHARACTERISTIC FUNCTION-METHOD IN THE STOCHASTIC-THEORY OF CHROMATOGRAPHY [J].
DONDI, F ;
REMELLI, M .
JOURNAL OF PHYSICAL CHEMISTRY, 1986, 90 (09) :1885-1891
[6]  
Dondi F., 1992, THEORETICAL ADV CHRO
[7]   CHARACTERIZATION OF SMALL VARIATIONS IN PROFILES OF CHROMATOGRAPHIC ELUTION PEAKS AND EFFECT OF NONLINEARITY OF SORPTION ISOTHERM [J].
EXCOFFIER, JL ;
JAULMES, A ;
VIDALMADJAR, C ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1982, 54 (12) :1941-1947
[8]   Intraparticle mass transfer in high-speed chromatography of proteins [J].
Farnan, D ;
Frey, DD ;
Horvath, C .
BIOTECHNOLOGY PROGRESS, 1997, 13 (04) :429-439
[9]   Stochastic-dispersive theory of chromatography [J].
Felinger, A ;
Cavazzini, A ;
Remelli, M ;
Dondi, F .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4472-4479
[10]  
FELINGER A, 1998, DATE ANAL SIGNAL PRO, pCH3