Design and characterization of a hydrodynamically confined microflow device for applying controlled loads to investigate single-cell mechanics

被引:1
|
作者
Christ, Kevin V. [1 ,5 ]
Park, Choongbae [2 ,3 ]
Masters, Kristyn S. [4 ]
Turner, Kevin T. [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[2] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[3] Texas A&M Univ, Dept Mech & Ind Engn, Kingsville, TX 78363 USA
[4] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[5] Honeywell Int, Aerosp Adv Technol, Plymouth, MN USA
关键词
Microfluidic probe; Hydrodynamically confined flows; Computational fluid dynamics-based design; Cell mechanics; SUBSTRATE STIFFNESS; LIVING CELLS; ADHESION; MECHANOTRANSDUCTION; STRENGTH; SYSTEMS; GLASS;
D O I
10.1007/s10404-019-2210-5
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Single-cell mechanics measurements are crucial in understanding mechanotransduction and cellular properties, such as adhesion and stiffness. Here, we present a microfluidic probe device that can generate controlled hydrodynamic loads on single cells in an open cell culture environment. The device is optimized to produce uniform stresses across the area of a cell for cell adhesion measurements. Microfluidic probe (MFP) devices that can be used to create hydrodynamically confined flows (HCMs) have emerged as a unique device for selectively treating cells and surfaces. Typical MFP devices generate complex-shaped flows and non-uniform hydrodynamic loads on the surface beneath the device. We have used computational fluid dynamics to optimize the port geometry of the MFP device to generate an HCM with uniform shear stresses in a region beneath the device. The devices were fabricated from a combination of silicon and PDMS and characterized through flow experiments above a polyacrylamide gel seeded with fluorescent beads. Bead displacements were measured as a function of flow conditions and general agreement with the model was obtained. Finally, we have used the devices to characterize the adhesion strength of patterned fibroblast cells adhered to a collagen-coated substrate. The results presented establish a design for an MFP device that can apply controlled mechanical forces to cells in open liquid environments.
引用
收藏
页数:14
相关论文
共 5 条
  • [1] Design and characterization of a hydrodynamically confined microflow device for applying controlled loads to investigate single-cell mechanics
    Kevin V. Christ
    Choongbae Park
    Kristyn S. Masters
    Kevin T. Turner
    Microfluidics and Nanofluidics, 2019, 23
  • [2] A Microfluidic Micropipette Aspiration Device to Study Single-Cell Mechanics Inspired by the Principle of Wheatstone Bridge
    Li, Yong-Jiang
    Yang, Yu-Nong
    Zhang, Hai-Jun
    Xue, Chun-Dong
    Zeng, De-Pei
    Cao, Tun
    Qin, Kai-Rong
    MICROMACHINES, 2019, 10 (02)
  • [3] Design and characterization of nanoknife with buffering beam for in situ single-cell cutting
    Shen, Yajing
    Nakajima, Masahiro
    Yang, Zhan
    Kojima, Seiji
    Homma, Michio
    Fukuda, Toshio
    NANOTECHNOLOGY, 2011, 22 (30)
  • [4] A novel method for assessing adherent single-cell stiffness in tension: design and testing of a substrate-based live cell functional imaging device
    Bartalena, Guido
    Grieder, Reto
    Sharma, Ram I.
    Zambelli, Tomaso
    Muff, Roman
    Snedeker, Jess G.
    BIOMEDICAL MICRODEVICES, 2011, 13 (02) : 291 - 301
  • [5] A novel method for assessing adherent single-cell stiffness in tension: design and testing of a substrate-based live cell functional imaging device
    Guido Bartalena
    Reto Grieder
    Ram I. Sharma
    Tomaso Zambelli
    Roman Muff
    Jess G. Snedeker
    Biomedical Microdevices, 2011, 13 : 291 - 301