Discharge of Air Gaps During Ground Potential Live-Line Work on Transmission Lines

被引:22
作者
Gao, Jiachen [1 ]
Wang, Linong [1 ]
Li, Guanlin [1 ]
Fang, Yaqi [2 ]
Song, Bin [1 ]
Xiao, Bin [3 ]
Liu, Kai [3 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Hubei Univ Technol, Sch Elect & Elect Engn, Wuhan 430068, Peoples R China
[3] China Elect Power Res Inst, Wuhan 430076, Peoples R China
关键词
Air gap discharge; Breakdown voltage prediction; Discharge model; Live-line work; UHV transmission lines; SWITCHING IMPULSE STRENGTH; LEADER INCEPTION; MODEL; BREAKDOWN; TOWER; INSULATION;
D O I
10.1016/j.epsr.2020.106519
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ground potential live-line work (GPLW) is a typical type of live-line work on transmission lines. In order to ensure the safety of live-line workers and reduce the consumption of test resources, the discharge of air gaps during GPLW on transmission lines was studied. Firstly, a breakdown voltage prediction method of GPLW air gaps was proposed, which can predict the breakdown voltage of GPLW air gaps. Subsequently, a discharge model of GPLW air gaps was proposed as well, so that the discharge characteristics of GPLW air gaps under different gap distances can be obtained more convenient. The prediction method and the discharge model were verified by switching impulse discharge tests of GPLW air gaps on UHV transmission lines, and the calculated results were close to the test results. Finally, the influence of live-line worker postures on discharge characteristics was studied. The results showed that workers should avoid causing protrusions of body parts in the course of work, which is more conducive to safety.
引用
收藏
页数:9
相关论文
共 35 条
[1]  
[Anonymous], 5162009 IEEE
[2]  
[Anonymous], 2013, IEC 61472-2013
[3]   A new static calculation of the streamer region for long spark gaps [J].
Arevalo, Liliana ;
Cooray, Vernon ;
Wu, Dong ;
Jacobson, Bjorn .
JOURNAL OF ELECTROSTATICS, 2012, 70 (01) :15-19
[4]   SWITCHING SURGE STRENGTH OF LARGE AIR GAPS - PHYSICAL APPROACH [J].
CARRARA, G ;
THIONE, L .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (02) :512-524
[5]   SWITCHING IMPULSE STRENGTH OF PHASE-TO-EARTH UHV EXTERNAL INSULATION - RESEARCH AT THE 1000 KV PROJECT [J].
CORTINA, R ;
GARBAGNATI, E ;
PIGINI, A ;
SARTORIO, G ;
THIONE, L .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (11) :3161-3168
[6]   Numerical Modeling of Electrical Discharges in Long Air Gaps Tested With Positive Switching Impulses [J].
Diaz, Oscar ;
Cooray, Vernon ;
Arevalo, Liliana .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (03) :611-621
[7]   Influence of front time on positive switching impulse discharge characteristics of UHVDC tower gaps [J].
Ding, Yujian ;
Zhuang, Chijie ;
Yao, Xiuyuan ;
Zhou, Xuan ;
He, Jinliang ;
Zeng, Rong .
ELECTRIC POWER SYSTEMS RESEARCH, 2019, 172 :32-37
[8]  
Elek A., 1961, IEEE T POWER APPAR S, V80, P897, DOI [10.1109/AIEEPAS.1961.4501169., DOI 10.1109/AIEEPAS.1961.4501169]
[9]   A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps [J].
Fang, Yaqi ;
Wang, Linong ;
Li, Rui ;
Zhang, Qiushi ;
Gao, Jiachen ;
Song, Bin .
IEEE ACCESS, 2019, 7 :71472-71480
[10]   A model for long air gap discharge using an equivalent electrical network [J].
Fofana, I ;
Beroual, A .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (02) :273-282