Consensus-Based Secondary Frequency and Voltage Droop Control of Virtual Synchronous Generators for Isolated AC Micro-Grids

被引:162
作者
Lu, Lin-Yu [1 ]
Chu, Chia-Chi [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu 30013, Taiwan
关键词
Consensus algorithm; distributed interface converters (DICs); droop control; micro-grid (MG); transient energy function (TEF); virtual synchronous generator (VSG); ANALYTICAL ENERGY FUNCTIONS; POWER-SYSTEMS; MULTIAGENT SYSTEMS; SYNCHRONVERTERS INVERTERS; HIERARCHICAL CONTROL; SWITCHING TOPOLOGY; STABILITY ANALYSIS; LYAPUNOV FUNCTION; SYNCHRONIZATION; CONVERTERS;
D O I
10.1109/JETCAS.2015.2462093
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the penetration of renewable energy sources is increasing in the AC micro-grid, the stability of the closed-loop system has raised a major concern since conventional distributed interface converters (DICs) used in the AC micro-grid do not have a rotating mass, and hence low inertia. High penetration of DIC-based micro-grid may result in poor frequency and voltage response during large disturbance. In order to overcome this difficulty, the virtual synchronous generator (VSGs) was proposed recently in which the DIC mimics conventional synchronous generators (SGs) by designing proper parameters of the SG into each local droop control mechanism of the DIC. Meanwhile, due to the recent advances of distributed control, the concept of consensus-based control can be applied to study this droop control problem of VSGs. One important feature of this consensus-based control is that it can be implemented on each local DIC with communications among their neighboring DICs. In contrast to most existing secondary control schemes, no central controller is required. Under this framework, if DICs are redesigned as VSGs, the frequency and voltage of each DIC can be restored to their pre-specified values obtained from the steady-state analysis. In addition, the proper real and reactive power sharing still can be achieved according to the nominal rating of each DIC. The stability of the closed-loop system is ensured by the transient energy function under certain mild conditions. Numerical experiments of a 14-bus/6-DIC micro-grid system on real-time simulators are performed to validate the effectiveness of the proposed control mechanism.
引用
收藏
页码:443 / 455
页数:13
相关论文
共 51 条
[1]   A Structure-Preserving Model and Sufficient Condition for Frequency Synchronization of Lossless Droop Inverter-Based AC Networks [J].
Ainsworth, Nathan ;
Grijalva, Santiago .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (04) :4310-4319
[2]   Power System Stabilization Using Virtual Synchronous Generator With Alternating Moment of Inertia [J].
Alipoor, Jaber ;
Miura, Yushi ;
Ise, Toshifumi .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2015, 3 (02) :451-458
[3]  
[Anonymous], IEEE Trans. Power Electron.
[4]   A STRUCTURE PRESERVING MODEL FOR POWER SYSTEM STABILITY ANALYSIS [J].
BERGEN, AR ;
HILL, DJ .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (01) :25-35
[5]   LYAPUNOV FUNCTION FOR MULTIMACHINE POWER-SYSTEMS WITH GENERATOR FLUX DECAY AND VOLTAGE DEPENDENT LOADS [J].
BERGEN, AR ;
HILL, DJ ;
DEMARCOT, CL .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 1986, 8 (01) :2-10
[6]  
Bergen AR., 2000, Power System Analysis
[7]   Hierarchical Structure of Microgrids Control System [J].
Bidram, Ali ;
Davoudi, Ali .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) :1963-1976
[8]   Lyapunov function for power system's with transfer conductances: Extension of the invariance principle [J].
Bretas, NG ;
Alberto, LFC .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) :769-777
[9]  
CHANDORKAR MC, 1994, IEEE POWER ELECTRON, P197, DOI 10.1109/PESC.1994.349730
[10]  
Chiang H.-D., 2011, Direct Methods for Stability Analysis of Electric Power Systems: Theoretical Foundation, BCU Methodologies, and Applications