Quantitative analysis of steroid hormones in human hair using a column-switching LC-APCI-MS/MS assay

被引:330
|
作者
Gao, Wei [1 ,2 ]
Stalder, Tobias [2 ]
Foley, Paul [2 ]
Rauh, Manfred [3 ]
Deng, Huihua [1 ]
Kirschbaum, Clemens [2 ]
机构
[1] Southeast Univ, Res Ctr Learning Sci, Nanjing 210096, Jiangsu, Peoples R China
[2] Tech Univ Dresden, Dept Psychol, D-01062 Dresden, Germany
[3] Univ Klinikum Erlangen, Kinder & Jugendklin, D-91054 Erlangen, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2013年 / 928卷
关键词
Steroid hormone; Hair; Mass spectrometry; Chromatography; On-line solid phase extraction; TANDEM MASS-SPECTROMETRY; ADRENAL-STEROIDS; CORTISOL; CORTICOSTEROIDS; QUANTIFICATION;
D O I
10.1016/j.jchromb.2013.03.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of steroid hormones in hair is increasingly used in the field of stress-related research to obtain a retrospective index of integrated long-term hormone secretion. Here, most laboratories have so far relied on immunochemical assays originally developed for salivary analyses. Although these assays are fast and easy to perform, they have a reduced reliability and specificity due to cross-reactivity with other substances and are limited to the detection of one hormone at a time. Here, we report the development of a LC-MS/MS-based method for simultaneous identification of endogenous concentrations of seven steroid hormones (cortisol, cortisone, testosterone, progesterone, corticosterone, dehydroepiandrosterone (DHEA) and androstenedione) in human hair. Hair samples were washed with isopropanol and steroid hormones were extracted from 10 mg whole, nonpulverized hair by methanol incubation. A column switching strategy for on-line solid phase extraction (SPE) was applied, followed by analyte detection on an AB Sciex API5000 QTrap mass spectrometer. Results indicated linearity of the method for all steroids over ranges of 0.09-90 pg/mg (0.9-900 pg/mg for DHEA) with correlation coefficients ranging between 0.9995 and 0.9999. Intra- and inter-assay coefficients of variation were between 3.7 and 9.1%. The limits of quantification (LOQ) were below (or equal to) 0.1 pg/mg for all steroids, except of DHEA for which the LOQ was 0.9 pg/mg. An analysis of 30 natural hair samples (15 men/15 women) using this method confirmed that all steroid hormones could be quantified at endogenous levels in each individual. In addition, the use of whole hair samples and on-line SPE resulted in a significant reduction in sample throughput times, increasing the applicability of this method for research questions where a larger number of samples needs to be processed. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] Sensitive Analysis of Wilforidine in Human Plasma by LC-APCI-MS/MS
    Cai, Meiqiang
    Shen, Chenyi
    Jin, Micong
    CHROMATOGRAPHIA, 2013, 76 (15-16) : 985 - 991
  • [2] Determination of cocaine and metabolites in hair by column-switching LC-MS-MS analysis
    Rabelo Alves, Marcela Nogueira
    Zanchetti, Gabriele
    Piccinotti, Alberto
    Tameni, Silvia
    De Martinis, Bruno Spinosa
    Polettini, Aldo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (19) : 6299 - 6306
  • [3] Fast and Reliable Determination of Voriconazole in Human Plasma by LC-APCI-MS/MS
    Xiong, Xin
    Duan, Jingli
    Zhai, Suodi
    Wang, Lijue
    Lan, Xi
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2010, 74 (10) : 2151 - 2153
  • [4] LC-MS based analysis of endogenous steroid hormones in human hair
    Gao, Wei
    Kirschbaum, Clemens
    Grass, Juliane
    Stalder, Tobias
    JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 2016, 162 : 92 - 99
  • [5] Determination of endogenous corticosterone in rodent's blood, brain and hair with LC-APCI-MS/MS
    Yu, Tian
    Xu, Hang
    Wang, Weiwen
    Li, Shifei
    Chen, Zheng
    Deng, Huihua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 267 - 276
  • [6] Quantitative Analysis of Chloramphenicol in Royal Jelly by Column-switching LC-MS/MS Using a Pretreatment Column with a Higher-pressure Capability
    Kawano, Shin-ichi
    Hayakawa, Yoshihiro
    Hashi, Yuki
    Lin, Jin-Ming
    ANALYTICAL SCIENCES, 2015, 31 (05) : 445 - 450
  • [7] LC-APCI-MS/MS assay for quantitation of ethyl esters of eicosapentaenoic acid and docosahexaenoic acid in human plasma and its application in a pharmacokinetic study
    Li, Le
    Xia, Ying
    Zhao, Shunbo
    Ding, Li
    Ji, Shunli
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [8] LC-APCI+-MS/MS method for the analysis of ten hormones and two endocannabinoids in plasma and hair from the mice with different gut microbiota
    Chu, Liuxi
    Li, Na
    Deng, Jia
    Wu, Yan
    Yang, Haoran
    Wang, Wei
    Zhou, Dongrui
    Deng, Huihua
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [9] Methods for the analysis of organophosphorus flame retardantsComparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 475 - 481
  • [10] LC-APCI-MS Simultaneous Determination of Barbital, Amobarbital, Phenobarbital and Secobarbital in Human Plasma
    Ye, Faqing
    Pan, Jianchun
    Hu, Guoxin
    Lin, Dan
    Zhu, Jiayin
    Wang, Xianqin
    CHROMATOGRAPHIA, 2010, 72 (7-8) : 743 - 746