Cutaneous small-vessel vasculitis following hysterosalpingo-foam sonography (HyFoSy)

被引:14
作者
Ludwin, A. [1 ,2 ]
Ludwin, I. [1 ,2 ]
Szczeklik, W. [3 ]
Martins, W. P. [4 ]
机构
[1] Jagiellonian Univ, Med Coll, Dept Gynecol & Oncol, Kopernika 23, PL-31501 Krakow, Poland
[2] Private Med Ctr, Ludwin & Ludwin Gynecol, Krakow, Poland
[3] Jagiellonian Univ, Med Coll, Dept Med, Krakow, Poland
[4] SEMEAR Fertilidade, Reprod Med, Ribeirao Preto, Brazil
关键词
contrast media; ExEm Foam; Fallopian-tube patency test; glycerol; HyCoSy; hydroxyethyl cellulose; HyFoSy; small-vessel vasculitis; CONSENSUS CONFERENCE NOMENCLATURE; TUBAL PATENCY; UTERINE CAVITY; SAFETY;
D O I
10.1002/uog.20372
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present a case of diffuse skin immune reaction, diagnosed as cutaneous small-vessel vasculitis, following assessment of tubal patency by contrast ultrasound, which appears to be the first reported case of hypersensitivity reaction to sonographic tubal patency testing, based on a literature search. A 32-year-old woman presented with non-thrombocytopenic palpable purpura the day after assessment of tubal patency by two-/three-dimensional hysterosalpingo-foam sonography (HyFoSy) using ExEm (R) Foam. During real-time ultrasound, the observer identified flow in only the right tube when using saline with air as contrast medium; however, the same observer identified flow in both tubes after injecting ExEm Foam and the woman left the clinic without any complications. The next day, the patient was admitted with a complaint of a red-purple skin rash noticed the same morning, associated with moderate leg pain. Slow-motion analysis of the recorded videos and three-dimensional ultrasound datasets showed previously unnoticed venous intravasation of ExEm Foam into the myometrial vessels. Palpable purpura is typically found in vasculitis as a result of extravasation of red cells outside the inflamed blood vessel. This previously unreported side effect of tubal patency testing by HyFoSy, its potential rare organ consequences, as well as unknown consequences of venous intravasation by foam, should be included in the informed consent prior to the examination. Copyright (C) 2019 ISUOG. Published by John Wiley & Sons Ltd.
引用
收藏
页码:831 / 834
页数:4
相关论文
共 18 条
[1]   Venous Intravasation as a Complication and Potential Pitfall During Hysterosalpingography: Re-Emerging Study with a Novel Classification [J].
Dusak, Abdurrahim ;
Soydinc, Hatice E. ;
Onder, Hakan ;
Ekinci, Faysal ;
Goruk, Neval Y. ;
Hamidi, Cihat ;
Bilici, Aslan .
JOURNAL OF CLINICAL IMAGING SCIENCE, 2013, 3
[2]   First experiences with hysterosalpingo-foam sonography (HyFoSy) for office tubal patency testing [J].
Emanuel, Mark Hans ;
van Vliet, Michelle ;
Weber, Maaike ;
Exalto, Niek .
HUMAN REPRODUCTION, 2012, 27 (01) :114-117
[3]   Safety aspects and side-effects of ExEm-gel and foam for uterine cavity distension and tubal patency testing [J].
Exalto, Niek ;
Stassen, Mario ;
Emanuel, Mark Hans .
REPRODUCTIVE BIOMEDICINE ONLINE, 2014, 29 (05) :534-540
[4]   Intravasation Affects the Diagnostic Image Quality of Transvaginal 4-Dimensional Hysterosalpingo-Contrast Sonography With SonoVue [J].
He, Yanni ;
Wu, Haorong ;
Xiong, Ran ;
Liu, Hongmei ;
Shi, Jiayao ;
Xu, Jingjiao ;
Zhang, Ning ;
Liu, Yu .
JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (08) :2169-2180
[5]   Single-organ cutaneous small-vessel vasculitis according to the 2012 revised International Chapel Hill Consensus Conference Nomenclature of Vasculitides: a study of 60 patients from a series of 766 cutaneous vasculitis cases [J].
Loricera, Javier ;
Blanco, Ricardo ;
Ortiz-Sanjuan, Francisco ;
Hernandez, Jose L. ;
Pina, Trinitario ;
Carmen Gonzalez-Vela, M. ;
Calvo-Rio, Vanesa ;
Rueda-Gotor, Javier ;
Alvarez, Lino ;
Gonzalez-Lopez, Marcos A. ;
Marcellan, Maria ;
Gonzalez-Gay, Miguel A. .
RHEUMATOLOGY, 2015, 54 (01) :77-82
[6]   Congenital Uterine Malformation by Experts (CUME): diagnostic criteria for T-shaped uterus [J].
Ludwin, A. ;
Coelho Neto, M. A. ;
Ludwin, I ;
Nastri, C. O. ;
Costa, W. ;
Acien, M. ;
Alcazar, J. L. ;
Benacerraf, B. ;
Condous, G. ;
DeCherney, A. ;
De Wilde, R-L ;
Diamond, M. P. ;
Emanuel, M. H. ;
Guerriero, S. ;
Hurd, W. ;
Levine, D. ;
Lindheim, S. ;
Pellicer, A. ;
Petraglia, F. ;
Saridogan, E. ;
Martins, W. P. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2020, 55 (06) :815-829
[7]   Venous intravasation during evaluation of tubal patency by ultrasound contrast imaging [J].
Ludwin, A. ;
Ludwin, I. ;
Martins, W. P. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 51 (01) :143-+
[8]   Congenital Uterine Malformation by Experts (CUME): better criteria for distinguishing between normal/arcuate and septate uterus? [J].
Ludwin, A. ;
Martins, W. P. ;
Nastri, C. O. ;
Ludwin, I. ;
Coelho Neto, M. A. ;
Leitao, V. M. ;
Acien, M. ;
Alcazar, J. L. ;
Benacerraf, B. ;
Condous, G. ;
De Wilde, R. -L. ;
Emanuel, M. H. ;
Gibbons, W. ;
Guerriero, S. ;
Hurd, W. W. ;
Levine, D. ;
Lindheim, S. ;
Pellicer, A. ;
Petraglia, F. ;
Saridogan, E. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2018, 51 (01) :101-109
[9]   Hysterosalpingo-lidocaine-foam sonography combined with power Doppler imaging (HyLiFoSy-PD) in tubal patency assessment: 'flaming tube' sign [J].
Ludwin, A. ;
Nastri, C. O. ;
Ludwin, I. ;
Martins, W. P. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 50 (06) :808-810
[10]   Uterine cavity imaging, volume estimation and quantification of degree of deformity using automatic volume calculation: description of technique [J].
Ludwin, A. ;
Martins, W. P. ;
Ludwin, I. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2017, 50 (01) :138-140