A Hybrid Transducer to Magnetically and Ultrasonically Evaluate Magnetic Fluids

被引:13
作者
Bruno, Alexandre Colello [1 ]
Pavan, Theo Z. [1 ]
Baffa, Oswaldo [2 ]
Oliveira Carneiro, Antonio Adilton [1 ]
机构
[1] Univ Sao Paulo, Dept Fis, BR-14049 Ribeirao Preto, Brazil
[2] Univ Sao Paulo, Dept Fis, Fac Filosofia Ciencias & Letras Ribeirao Preto, BR-14049 Ribeirao Preto, Brazil
基金
巴西圣保罗研究基金会;
关键词
AC BIOSUSCEPTOMETRY; BIOMAGNETIC METHOD; STEEL NEEDLES; LIVER; IRON; DISINTEGRATION; MOTILITY; TABLETS;
D O I
10.1109/TUFFC.2013.2785
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound, magnetic fields, and optical techniques have been explored for clinical diagnosis and therapy. However, these techniques have limitations. In this study, we constructed and characterized a transducer to magnetically and ultrasonically investigate samples labeled with magnetic particles. The transducer is a hybrid system consisting of an ac biosusceptometer (ACB) and an ultrasonic transducer. The basic operation principle consisted of measuring the magnetization and microvibrations of ferromagnetic particles (37 and 70 mu m) mixed in yogurt and excited by an external alternating magnetic field generated by the ACB's excitation coils. The vibration of the ferromagnetic particles was measured in phantoms using a Doppler ultrasonic transducer; we verified the sensitivity to detecting the vibrations at low concentrations of ferromagnetic material (approximate to 1%). The responses of the susceptometer and Doppler ultrasound linearly depended on the voltage level applied to the magnetizing coils at low ferromagnetic particle concentrations (<= 5%). We also conducted a repeatability test on the prototype, which indicated a deviation of 0.94% and 0.25% in the Doppler and susceptometric measurements, respectively. We can conclude that the hybrid transducer technique has potential clinical applications.
引用
收藏
页码:2004 / 2012
页数:9
相关论文
共 39 条
[1]   AC BIOSUSCEPTOMETRY AS A METHOD FOR MEASURING GASTRIC CONTRACTION [J].
Agostinho, Marcelo ;
Americo, Madileine F. ;
Marques, Rozemeire G. ;
Zandona, Ednaldo Alexandre ;
Stelzer, Murilo ;
Cora, Luciana A. ;
Andreis, Uilian ;
Oliveira, Ricardo B. ;
Miranda, Jose Ricardo A. .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :5740-5743
[2]   Scintigraphic validation of AC Biosusceptometry to study the gastric motor activity and the intragastric distribution of food in humans [J].
Americo, M. F. ;
Oliveira, R. B. ;
Romeiro, F. G. ;
Baffa, O. ;
Cora, L. A. ;
Miranda, J. R. A. .
NEUROGASTROENTEROLOGY AND MOTILITY, 2007, 19 (10) :804-811
[3]  
Angulo Ivan L., 2008, Rev. Bras. Hematol. Hemoter., V30, P449, DOI 10.1590/S1516-84842008000600006
[4]  
[Anonymous], 2014, Diagnostic Ultrasound Imaging
[5]   Noninvasive liver-iron measurements with a room-temperature susceptometer [J].
Avrin, William F. ;
Kumar, Sankaran .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (04) :349-361
[6]   ANALYSIS AND DEVELOPMENT OF AC BIOSUSCEPTOMETER FOR OROCECAL TRANSIT-TIME MEASUREMENTS [J].
BAFFA, O ;
OLIVEIRA, RB ;
MIRANDA, JRA ;
TRONCON, LEA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (03) :353-357
[7]   Improvement of a technique for localization of steel needles in humans using a SQUID magnetometer [J].
Barbosa, CH ;
Monteiro, EC ;
Lima, EA ;
Santos, SF ;
Cavalcanti, EG ;
Ribeiro, PC .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :677-680
[8]  
BENMAIR Y, 1977, GASTROENTEROLOGY, V73, P1041
[9]   Hybrid System for Magnetic and Acoustic Measurement [J].
Bruno, A. C. ;
Baffa, O. ;
Carneiro, A. A. O. .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :761-764
[10]   Study of stomach motility using the relaxation of magnetic tracers [J].
Carneiro, AA ;
Baffa, O ;
Oliveira, RB .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (07) :1691-1697