The clinical impact of phase offset errors and different correction methods in cardiovascular magnetic resonance phase contrast imaging: a multi-scanner study

被引:14
作者
Minderhoud, Savine C. S. [1 ,2 ]
van der Velde, Nikki [1 ,2 ]
Wentzel, Jolanda J. [1 ]
van der Geest, Rob J. [3 ]
Attrach, Mohammed [2 ]
Wielopolski, Piotr A. [2 ]
Budde, Ricardo P. J. [1 ,2 ]
Helbing, Willem A. [2 ,4 ]
Roos-Hesselink, Jolien W. [1 ]
Hirsch, Alexander [1 ,2 ]
机构
[1] Univ Med Ctr Rotterdam, Erasmus Med Ctr, Dept Cardiol, POB 2040,Room Rg-419, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr Rotterdam, Dept Radiol & Nucl Med, Erasmus Med Ctr, Rotterdam, Netherlands
[3] Leiden Univ, Med Ctr, Div Image Proc, Dept Radiol, Leiden, Netherlands
[4] Univ Med Ctr Rotterdam, Div Pediat Cardiol, Dept Pediat, Erasmus Med Ctr, Rotterdam, Netherlands
关键词
Flow quantification; Cardiovascular magnetic resonance imaging; Phase contrast velocity imaging; Phase offset error; BLOOD-FLOW; MR; QUANTIFICATION; REGURGITATION;
D O I
10.1186/s12968-020-00659-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. Methods CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velocity offsets, net flow, clinically significant difference (deviation > 10% net flow), and regurgitation severity were assessed. Results Data from 175 patients (28 (17-38) years) were included, of which 84% had congenital heart disease. First, second and third order and optimized stationary tissue correction did not improve the velocity offsets and net flow measurements. Uncorrected measurements resulted in the least clinically significant differences in net flow compared to phantom corrected data. Optimized stationary tissue correction per scanner and software program resulted in net flow differences (> 10%) in 19% (MASS) and 30% (Circle cvi42) of all measurements compared to 18% (MASS) and 23% (Circle cvi42) with no correction. Compared to phantom correction, regurgitation reclassification was the least common using uncorrected data. One CMR scanner performed worse and significant net flow differences of > 10% were present both with and without stationary tissue correction in more than 30% of all measurements. Conclusion Phase offset errors had a significant impact on net flow quantification, regurgitation assessment and varied greatly between CMR scanners. Background phase correction using stationary tissue correction worsened accuracy compared to no correction on three GE Healthcare CMR scanners. Therefore, careful assessment of phase offset errors at each individual scanner is essential to determine whether routine use of phantom correction is necessary.
引用
收藏
页数:13
相关论文
共 19 条
  • [1] ESC Guidelines for the management of grown-up congenital heart disease (new version 2010)
    Baumgartner, Helmut
    Bonhoeffer, Philipp
    De Groot, Natasja M. S.
    de Haan, Fokko
    Deanfield, John Erik
    Galie, Nazzareno
    Gatzoulis, Michael A.
    Gohlke-Baerwolf, Christa
    Kaemmerer, Harald
    Kilner, Philip
    Meijboom, Folkert
    Mulder, Barbara J. M.
    Oechslin, Erwin
    Oliver, Jose M.
    Serraf, Alain
    Szatmari, Andras
    Thaulow, Erik
    Vouhe, Pascal R.
    Walma, Edmond
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (23) : 2915 - 2957
  • [2] Concomitant gradient terms in phase contrast MR: Analysis and correction
    Bernstein, MA
    Zhou, XHJ
    Polzin, JA
    King, KF
    Ganin, A
    Pelc, NJ
    Glover, GH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (02) : 300 - 308
  • [3] Analysis of temperature dependence of background phase errors in phase-contrast cardiovascular magnetic resonance
    Busch, Julia
    Vannesjo, S. Johanna
    Barmet, Christoph
    Pruessmann, Klaas P.
    Kozerke, Sebastian
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [4] Baseline correction of phase contrast images improves quantification of blood flow in the great vessels
    Chernobelsky, Alexander
    Shubayev, Oleg
    Comeau, Cindy R.
    Wolff, Steven D.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (04) : 681 - 685
  • [5] Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease
    Fratz, Sohrab
    Chung, Taylor
    Greil, Gerald F.
    Samyn, Margaret M.
    Taylor, Andrew M.
    Buechel, Emanuela R. Valsangiacomo
    Yoo, Shi-Joon
    Powell, Andrew J.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [6] A multi-center inter-manufacturer study of the temporal stability of phase-contrast velocity mapping background offset errors
    Gatehouse, Peter D.
    Rolf, Marijn P.
    Bloch, Karin Markenroth
    Graves, Martin J.
    Kilner, Philip J.
    Firmin, David N.
    Hofman, Mark B. M.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [7] Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurements
    Gatehouse, Peter D.
    Rolf, Marijn P.
    Graves, Martin J.
    Hofman, Mark B. M.
    Totman, John
    Werner, Beat
    Quest, Rebecca A.
    Liu, Yingmin
    von Spiczak, Jochen
    Dieringer, Matthias
    Firmin, David N.
    van Rossum, Albert
    Lombardi, Massimo
    Schwitter, Juerg
    Schulz-Menger, Jeanette
    Kilner, Philip J.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12
  • [8] Analysis and correction of background velocity offsets in phase-contrast flow measurements using magnetic field monitoring
    Giese, Daniel
    Haeberlin, Maximilian
    Barmet, Christoph
    Pruessmann, Klaas P.
    Schaeffter, Tobias
    Kozerke, Sebastian
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1294 - 1302
  • [9] In-vivo validation of interpolation-based phase offset correction in cardiovascular magnetic resonance flow quantification: a multi-vendor, multi-center study
    Hofman, Mark B. M.
    Rodenburg, Manouk J. A.
    Bloch, Karin Markenroth
    Werner, Beat
    Westenberg, Jos J. M.
    Buechel, Emanuela R. Valsangiacomo
    Nijveldt, Robin
    Spruijt, Onno A.
    Kilner, Philip J.
    van Rossum, Albert C.
    Gatehouse, Peter D.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
  • [10] Baseline correction of phase-contrast images in congenital cardiovascular magnetic resonance
    Holland, Brian J.
    Printz, Beth F.
    Lai, Wyman W.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2010, 12