A compact and low-cost laser induced fluorescence detector with silicon based photodetector assembly for capillary flow systems

被引:25
作者
Geng, Xuhui [1 ]
Shi, Meng [1 ,2 ]
Ning, Haijing [1 ]
Feng, Chunbo [1 ]
Guan, Yafeng [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Instrumentat & Analyt Chem, CAS Key Lab Separat Sci Analyt Chem, 457 Zhongshan Rd, Dalian 116023, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Laser induced fluorescence; Compact; Low-cost; Single cell; LIGHT-EMITTING-DIODES; SINGLE-CELL; LIQUID-CHROMATOGRAPHY; ELECTROPHORESIS;
D O I
10.1016/j.talanta.2018.01.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A compact and low-cost laser induced fluorescence (LIF) detector based on confocal structure for capillary flow systems was developed and applied for analysis of Her2 protein on single Hela cells. A low-power and low-cost 450 nm laser diode (LD) instead of a high quality laser was used as excitation light source. A compact optical design together with shortened optical path length improved the optical efficiency and detection sensitivity. A superior silicon based photodetector assembly was used for fluorescence detection instead of a photomultiplier (PMT). The limit of detection (LOD) for fluorescein sodium was 3 x 10(-12) M or 165 fluorescein molecules in detection volume measured on a homemade capillary electroosmotic driven (EOD)-LIF system, which was similar to commercial LIFs. Compared to commercial LIFs, the whole volume of our LIF was reduced to 1/2-1/3, and the cost was less than 1/3 of them.
引用
收藏
页码:279 / 284
页数:6
相关论文
共 20 条
  • [1] A hyphenated optical trap capillary electrophoresis laser induced native fluorescence system for single-cell chemical analysis
    Cecala, Christine
    Rubakhin, Stanislav S.
    Mitchell, Jennifer W.
    Gillette, Martha U.
    Sweedler, Jonathan V.
    [J]. ANALYST, 2012, 137 (13) : 2965 - 2972
  • [2] A sequential injection fluorometric procedure for rapid determination of total protein in human serum
    Chen, Xuwei
    Wang, Jianhua
    [J]. TALANTA, 2006, 69 (03) : 681 - 685
  • [3] Low-picomolar limits of detection using high-power light-emitting diodes for fluorescence
    de Jong, EP
    Lucy, CA
    [J]. ANALYST, 2006, 131 (05) : 664 - 669
  • [4] Analysis of doxorubicin uptake in single human leukemia K562 cells using capillary electrophoresis coupled with laser-induced fluorescence detection
    Deng, Bin
    Wang, Zhiming
    Song, Jian
    Xiao, Yuxiu
    Chen, Dan
    Huang, Jun
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (07) : 2143 - 2152
  • [5] A handheld laser-induced fluorescence detector for multiple applications
    Fang, Xiao-Xia
    Li, Han-Yang
    Fang, Pan
    Pan, Jian-Zhang
    Fang, Qun
    [J]. TALANTA, 2016, 150 : 135 - 141
  • [6] Laser-induced fluorescence detection system for microfluidic chips based on an orthogonal optical arrangement
    Fu, Jing-Lin
    Fang, Qun
    Zhang, Ting
    Jin, Xin-Hua
    Fang, Zhao-Lun
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (11) : 3827 - 3834
  • [7] "Getting the best sensitivity from on-capillary fluorescence detection in capillary electrophoresis" - A tutorial
    Galievsky, Victor A.
    Stasheuski, Alexander S.
    Krylov, Sergey N.
    [J]. ANALYTICA CHIMICA ACTA, 2016, 935 : 58 - 81
  • [8] A facile and high sensitive micro fluorimeter based on light emitting diode and photodiode
    Geng, Xuhui
    Gao, Yan
    Feng, Chunbo
    Guan, Yafeng
    [J]. TALANTA, 2017, 175 : 183 - 188
  • [9] Signal-to-noise ratio enhancement of the compact light-emitting diode-induced fluorescence detector
    Geng, Xuhui
    Wu, Dapeng
    Wu, Qian
    Guan, Yafeng
    [J]. TALANTA, 2012, 100 : 27 - 31
  • [10] A compact and highly sensitive light-emitting diode-induced fluorescence detector for capillary flow systems
    Geng, Xuhui
    Wu, Dapeng
    Guan, Yafeng
    [J]. TALANTA, 2012, 88 : 463 - 467