Hearing Preservation Surgery: Cochleostomy or Round Window Approach? A Systematic Review

被引:94
作者
Havenith, Sarah [1 ,2 ]
Lammers, Marc J. W. [1 ,2 ]
Tange, Rinze A. [1 ]
Trabalzini, Franco [3 ]
della Volpe, Antonio [4 ]
van der Heijden, Geert J. M. G. [1 ,5 ]
Grolman, Wilko [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Otorhinolaryngol Head & Neck Surg, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Rudolf Magnus Inst Neurosci, NL-3508 GA Utrecht, Netherlands
[3] Siena Univ Hosp, Dept Sense Organs, Otol & Skull Base Surg Unit, Siena, Italy
[4] Santobono Pausilipon Childrens Hosp, Otol & Cochlear Implant Unit, Naples, Italy
[5] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, NL-3508 GA Utrecht, Netherlands
关键词
Cochlear implantation; Electroacoustic stimulation; Residual hearing; Cochleostomy; Round window; Hearing preservation; Soft surgery; DEAFNESS COCHLEAR IMPLANTATION; ELECTRIC ACOUSTIC STIMULATION; LOW-FREQUENCY HEARING; FLEXSOFT ELECTRODE; RESIDUAL HEARING; AUDITORY-SYSTEM; CLINICAL-TRIAL; EXPERIENCE;
D O I
10.1097/MAO.0b013e318288643e
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives/Hypothesis: An increasing number of patients with low-frequency residual hearing are fitted with a cochlear implant. The challenge is to optimize cochlear implant device properties and develop atraumatic surgical techniques to preserve residual hearing. In view of the ongoing debate about the optimal procedure for opening the cochlea during cochlear implantation, we reviewed the evidence on the round window and the cochleostomy insertion techniques and compared their effects on postoperative residual hearing. Design: Systematic review. Methods: Electronic databases were systematically searched for relevant studies published up to January 2012. All studies reporting on residual hearing and hearing preservation surgery were included. Results: Sixteen studies, with a total of 170 patients, were included. There were no studies directly comparing both surgical insertion techniques. The methodologic quality of the studies was poor and might be subjected to a high risk of bias. Because there were no studies directly comparing the 2 techniques and controlling for possible influencing factors, differences between studies might also be influenced by intersurgeon variance in many facets regarding cochlear implantation surgery. The available data show a postoperative low-frequency hearing loss ranging from 10 to 30 dB at 125, 250, and 500 Hz, regardless of surgical technique. The number of patients with a postoperative complete hearing preservation ranged from 0% to 40% for the cochleostomy group and from 13% to 59% in the round window group. Conclusion: The available data do not show that there is a benefit of one surgical approach over the other regarding the preservation of residual hearing. To provide solid evidence, a double-blind randomized trial is needed, which compares the clinical outcomes, notably the degree of hearing preservation, of both surgical approaches.
引用
收藏
页码:667 / 674
页数:8
相关论文
共 23 条
[1]   Residual hearing preservation using the suprameatal approach for cochlear implantation [J].
Arnoldner, Christoph ;
Gstoettner, Wolfgang ;
Riss, Dominik ;
Wagenblast, Jens ;
Honeder, Clemens ;
Blineder, Michaela ;
Hamzavi, Jafar-Sasan ;
Jappel, Alexandra ;
Baumgartner, Wolf-Dieter .
WIENER KLINISCHE WOCHENSCHRIFT, 2011, 123 (19-20) :599-602
[2]  
Arnoldner C, 2010, ADV OTO-RHINO-LARYNG, V67, P116, DOI 10.1159/000262603
[3]   Outcomes in adults implanted with the FLEXsoft electrode [J].
Baumgartner, Wolf-Dieter ;
Jappel, Alexandra ;
Morera, Constantino ;
Gstoettner, Wolfgang ;
Mueller, Joachim ;
Kiefer, Jan ;
Van de Heyning, Paul ;
Anderson, Ilona ;
Nielsen, Stefan Bryde .
ACTA OTO-LARYNGOLOGICA, 2007, 127 (06) :579-586
[4]  
Briggs Robert J S, 2006, Audiol Neurootol, V11 Suppl 1, P42, DOI 10.1159/000095613
[5]   Hearing Preservation Via a Cochleostomy Approach and Deep Insertion of a Standard Length Cochlear Implant Electrode [J].
Bruce, Iain Alexander ;
Bates, James Edward Homewood Mills ;
Melling, Christine ;
Mawman, Deborah ;
Green, Kevin Michael John .
OTOLOGY & NEUROTOLOGY, 2011, 32 (09) :1444-1447
[6]   Hybrid 10 Clinical Trial Preliminary Results [J].
Gantz, Bruce J. ;
Hansen, Marlan R. ;
Turner, Christopher W. ;
Oleson, Jacob J. ;
Reiss, Lina A. ;
Parkinson, Aaron J. .
AUDIOLOGY AND NEURO-OTOLOGY, 2009, 14 :32-38
[7]   Hearing preservation surgery: Psychophysical estimates of cochlear damage in recipients of a short electrode array [J].
Gifford, Rene H. ;
Dorman, Michael F. ;
Spahr, Anthony J. ;
Bacon, Sid P. ;
Skarzynski, Henryk ;
Lorens, Artur .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 124 (04) :2164-2173
[8]   Hearing preservation in cochlear implantation for electric acoustic stimulation [J].
Gstoettner, W ;
Kiefer, J ;
Baumgartner, WD ;
Pok, S ;
Peters, S ;
Adunka, O .
ACTA OTO-LARYNGOLOGICA, 2004, 124 (04) :348-352
[9]   A new electrode for residual hearing preservation in cochlear implantation: first clinical results [J].
Gstoettner, Wolfgang ;
Helbig, Silke ;
Settevendemie, Claudia ;
Baumann, Uwe ;
Wagenblast, Jens ;
Arnoldner, Christoph .
ACTA OTO-LARYNGOLOGICA, 2009, 129 (04) :372-379
[10]  
Gstoettner Wolfgang K, 2006, Audiol Neurootol, V11 Suppl 1, P49, DOI 10.1159/000095614