Forward Looking Intracardiac Imaging Catheters for Electrophysiology

被引:0
|
作者
Stephens, Douglas N. [1 ]
Cannata, Jonathan [2 ]
Liu, Ruibin [2 ]
Shung, K. Kirk [2 ]
Oralkan, Omer [3 ]
Nikoozadeh, Amin [3 ]
Khuri-Yakub, Pierre [3 ]
Nguyen, Hien [4 ]
Chia, Raymond [4 ]
Dentinger, Aaron [5 ]
Wildes, Douglas [5 ]
Thomenius, Kai E. [5 ]
Mahajan, Aman [6 ]
Shivkumar, Kalyanam [6 ]
Kim, K. [7 ]
O'Donnell, Matthew [7 ]
Sahn, David [8 ]
机构
[1] Univ Calif Davis, Davis, CA 95616 USA
[2] Univ Southern Calif, Los Angeles, CA USA
[3] Stanford Univ, Stanford, CA 94305 USA
[4] Irvine Biomed Corp, Irvine, CA USA
[5] Gen Elect Global Res, New York, NY USA
[6] Univ Calif Los Angeles, Los Angeles, CA USA
[7] Univ Michigan, Ann Arbor, MI USA
[8] Oregon Hlth & Sci Univ, Portland, ME USA
来源
2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS | 2006年
关键词
forward looking; electrophysiology; intracardiac echo; electroanatomical mapping; guidance; ultrasound; capacitive micromachined ultrasonic transducers; cMUT;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Minimally invasive electrophysiology interventions to treat cardiac arrhythmias are increasing worldwide due to advances in technologies that enable more effective clinical procedures. A forward imaging ultrasound catheter design has been developed and tested to advance the methods of integration of intracardiac imaging and electrophysiology sensing. The first catheters built have been constructed with a 9F (3mm) shaft and a large (15F) tip to support experimental wire ports adjacent to a 24 element phased array operating at 14MHz. The final tip design construction size will be 9F and possess an integrated metal electrode at the catheter distal end. Two forward looking array designs have been developed in parallel to produce two contrasting fine pitch (65 microns) 24 element phased array construction approaches. The first array has been assembled with a standard 2-2 composite PZT technology with the flex circuit mounted on the front facing side, and the second design is a cMUT version with a flip-chip bonded silicon die bonded to a backside flex circuit. The cMUT design requires a special interface to assure a safe element biasing scheme while enhancing the array's linearity and sensitivity. The first PZT array prototypes, built without explicit matching layers, have been characterized and agree with FEA and KLM analyses in operation at 14MHz. Matching layer variations have been used on the front layer flex circuit to optimize the sensitivity and bandwidth of the PZT arrays while minimizing the thermal boundary layer. Specially designed assembly approaches addressed the challenging forward looking array configurations that utilize interconnection flex circuits with bend radii at 250 microns. Animal studies have been performed utilizing beam forming adaptations for the forward looking imaging catheter operation on a Vingmed Vivid-7 system. The first piezoceramic array devices were used successfully to image the myocardium of the right atrium of a pig while simultaneous tissue ablation was performed.
引用
收藏
页码:702 / +
页数:2
相关论文
共 50 条
  • [1] Fully integrated CMUT-based forward-looking intracardiac imaging for electrophysiology
    Nikoozadeh, Amin
    Wygant, Ira O.
    Linl, Der-Song
    Oralkan, Oemer
    Ergun, Arif Sanli
    Thomenius, Kai
    Dentinger, Aaron
    Wildes, Douglas
    Akopyan, Gina
    Shivkumar, Kalyanam
    Mahajan, Aman
    Stephens, Douglas N.
    Sahn, David
    Khuri-Yakub, Pierre T.
    2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 900 - +
  • [2] Intracardiac Forward-Looking Ultrasound Imaging Catheters Using Capacitive Micromachined Ultrasonic Transducers
    Nikoozadeh, A.
    Wygant, I. O.
    Lin, D. -S.
    Oralkan, Oe
    Thomenius, K.
    Dentinger, A.
    Wildes, D.
    Akopyan, G.
    Shivkumar, K.
    Mahajan, A.
    Stephens, D. N.
    O'Donnell, M.
    Sahn, D.
    Khuri-Yakub, P. T.
    ACOUSTICAL IMAGING, VOL 30, 2011, 30 : 203 - 210
  • [3] Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing
    Stephens, Douglas N.
    Cannata, Jonathan
    Liu, Ruibin
    Zhao, Jian Zhong
    Shung, K. Kirk
    Nguyen, Hien
    Chia, Raymond
    Dentinger, Aaron
    Wildes, Douglas
    Thomenius, Kai E.
    Mahajan, Aman
    Shivkumar, Kalyanam
    Kim, Kang
    O'Donnell, Matthew
    Nikoozadeh, Amin
    Oralkan, Omer
    Khuri-Yakub, Pierre T.
    Sahn, David J.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (07) : 1570 - 1581
  • [4] Magnetocardiographic pacemapping for nonfluoroscopic localization of intracardiac electrophysiology catheters
    Fenici, R
    Pesola, K
    Korhonen, P
    Mäkijärvi, M
    Nenonen, J
    Toivonen, L
    Fenici, P
    Katila, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2492 - 2499
  • [5] Experimental Studies With a 9F Forward-Looking Intracardiac Imaging and Ablation Catheter
    Stephens, Douglas N.
    O'Donnell, Matthew
    Thomenius, Kai
    Dentinger, Aaron
    Wildes, Douglas
    Chen, Peter
    Shung, K. Kirk
    Cannata, Jonathan
    Khuri-Yakub, Pierre
    Oralkan, Omer
    Mahajan, Aman
    Shivkumar, Kalyanam
    Sahn, David J.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2009, 28 (02) : 207 - 215
  • [6] INTRACARDIAC ELECTROPHYSIOLOGY
    DAVIES, DW
    GERIATRIC CARDIOVASCULAR MEDICINE, 1988, 1 (03): : 193 - 196
  • [7] Imaging in urology - looking forward
    Grimm, Jan
    Hricak, Hedvig
    CURRENT OPINION IN UROLOGY, 2008, 18 (01) : 61 - 64
  • [8] Looking forward at npj Imaging
    Rita Strack
    npj Imaging, 2 (1):
  • [9] Intracardiac echocardiography in electrophysiology
    Dello Russo, A.
    Casella, M.
    Pelargonio, G.
    Bonelli, F.
    Santangeli, P.
    Fassini, G.
    Riva, S.
    Carbucicchio, C.
    Giraldi, F.
    De Iuliis, P.
    Bartoletti, S.
    Pintus, F.
    Di Biase, L.
    Pepi, M.
    Natale, A.
    Fiorentini, C.
    Tondo, C.
    MINERVA CARDIOANGIOLOGICA, 2010, 58 (03): : 333 - 342
  • [10] Electrophysiology study without intracardiac catheters. The value of proper Holter interpretation: A case report
    Enriquez, Andres
    Bittner, Alex
    Almehairi, Mohammed
    Baranchuk, Adrian
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (03) : 329 - 332