Analysis of bone-implant interaction phenomena by using a numerical approach

被引:63
作者
Natali, AN [1 ]
Pavan, PG [1 ]
Ruggero, AL [1 ]
机构
[1] Univ Padua, Ctr Mech Biol Mat, I-35131 Padua, Italy
关键词
bone-implant interface; bone properties; dental biomechanics; dental implants; numerical modeling;
D O I
10.1111/j.1600-0501.2005.01162.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of the present work is to investigate the interaction phenomena occurring between endosseus dental implants and peri-implant bone tissue. Material and methods: Detailed finite element models are adopted in order to analyze the actual behavior of bone-implant system depending on implant and anatomical site configuration and loading conditions. Different types of titanium dental implants are considered. Implant finite element models are obtained through a reverse engineering procedure and adopting specific software for the reconstruction of geometrical configuration. Anatomical sites are modeled starting from computerized tomography data, according to specific image processing procedures. Results: Occlusal static forces are applied to the implants and their effects on the bone-implant interface region are evaluated. The influence of several parameters, such as morphometry of anatomical site or loading condition, on the biomechanical response of bone-implant system is considered. Conclusions: The evaluation of the biomechanical response of implant-bone compound necessarily requires the adoption of accurate numerical models, accounting for the complex geometry of threaded implants, as well as of the anatomy of the patients to be able to provide for reliable results pertaining to stress/strain path on peri-implant bone tissue.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 41 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant -: A nonlinear finite element stress analysis
    Akça, K
    Çehreli, MC
    Iplikçioglu, H
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (04) : 444 - 454
  • [3] STATE-OF-THE-ART IN ORAL IMPLANTS
    ALBREKTSSON, T
    SENNERBY, L
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1991, 18 (06) : 474 - 481
  • [4] Berzins A, 1997, J BIOMED MATER RES, V34, P337
  • [5] Branemark P.I., 1985, TISSUE INTEGRATED PR, Vfirst, P11
  • [6] Biomechanical characterization of osseointegration during healing: An experimental in vivo study in the rat
    Branemark, R
    Ohrnell, LO
    Nilsson, P
    Thomsen, P
    [J]. BIOMATERIALS, 1997, 18 (14) : 969 - 978
  • [7] BRUNSKI J B, 1992, Clinical Materials, V10, P153, DOI 10.1016/0267-6605(92)90049-Y
  • [8] Brunski J B, 1999, Adv Dent Res, V13, P99
  • [9] Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
  • [10] Elasticity of alveolar bone near dental implant-bone interfaces after one month's healing
    Chang, MC
    Ko, CC
    Liu, CC
    Douglas, WH
    DeLong, R
    Seong, WJ
    Hodges, J
    An, KN
    [J]. JOURNAL OF BIOMECHANICS, 2003, 36 (08) : 1209 - 1214