Determination of putrescine, cadaverine, spermidine and spermine in different chemical matrices by high performance liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (HPLC-ESI-ITMS/MS)

被引:28
|
作者
Gonzalez Ibarra, Alan Alexander [1 ]
Wrobel, Katarzyna [1 ]
Corrales Escobosa, Alma Rosa [1 ]
Torres Elguera, Julio Cesar [1 ]
Eugenia Garay-Sevilla, Ma [2 ]
Wrobel, Kazimierz [1 ]
机构
[1] Univ Guanajuato, Dept Chem, Guanajuato 36000, Mexico
[2] Univ Guanajuato, Dept Med Sci, Guanajuato 36000, Mexico
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 1002卷
关键词
Aliphatic polyamines; 4-fluoro-3-nitrobenzenotrifluoride (FNBT); LC-MS; Multiple reaction monitoring; Plant abiotic stress; Diabetes; Urine; SOLID-PHASE EXTRACTION; BIOGENIC-AMINES; HUMAN URINE; LEPIDIUM-SATIVUM; CADMIUM STRESS; POLYAMINES; DERIVATIZATION; SAMPLES; FOODS; DERIVATIVES;
D O I
10.1016/j.jchromb.2015.08.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The goal of this work was to establish a simple HPLC-ESI-ITMS/MS procedure, suitable for the determination of four common aliphatic polyamines in two different types of biological matrices. To this end, 1,6-diaminohexane was used as the internal standard (IS) and 4-fluoro-3-nitrobenzenotrifluoride (FNBT) as the derivatizing agent. Formation of fully derivatized compounds was confirmed by high resolution ESI-QTOFMS and MS/MS analysis. Reversed phase chromatographic separation was carried out by gradient elution with 0.1% (v/v) formic acid and methanol. In a positive ESI mode, the following pairs of precursor/quantifier ions were used for multiple reaction monitoring: 467.4/261.0 for PUT, 481.2/461.1 for CAD, 713.7/261.0 for SPD, 959.8/507.2 for SPM and 495.3/475.2 for IS. On-column instrumental detection limits of four polyamines were in the range 0.62-2.14 fmol (0.039-0.215 ng/ml). Versatility was demonstrated by analyzing plant extracts and human urine; prior to derivatization, all samples were cleaned-up by dichloromethane extraction. The evaluated signal suppression/enhancement was in the range 82.3-115.4% and the percentage recoveries obtained in the method of standard addition were in the range 817-114.4%. Statistically significant differences in polyamines concentrations were found in garden cress exposed to Cd(II) versus control seedlings (t-test, p < 0.05); results obtained for urine from healthy volunteers and diabetic patients at different clinical conditions suggested possible utility of free polyamines as biomarkers of progressive diabetes. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 184
页数:9
相关论文
共 50 条
  • [31] Simultaneous determination of ephedrine and N-methylephedrine in urine by solid phase extraction-ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry
    Zhang Lin
    Zhang Fucheng
    Wang Zhaohong
    Jiang Ye
    Xu Meng
    Li Hong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 898 - 902
  • [32] Rapid Determination of the Primary Alkaloids in Illicit Heroin by High-Performance Liquid Chromatography with Tandem Mass Spectrometry (HPLC-MS/MS)
    Jovanov, Pavle
    Petrin-Milicevic, Marija
    Radosavljevic-Stevanovic, Natasa
    Vranes, Milan
    Belic, Sanja
    Sakac, Marijana
    Nikolov, Jovana
    Gadzuric, Slobodan
    ANALYTICAL LETTERS, 2021, 54 (07) : 1224 - 1232
  • [33] Determination of the metabolic profile of gentianine after oral administration to rats by high performance liquid chromatography/electrospray ionization-trap mass spectrometry
    Wu, Xiuhong
    Tang, Shuhan
    Jin, Yan
    Wang, Shanshan
    Wang, Xijun
    Hattori, Masao
    Zhang, Hailong
    Wang, Zhigang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 98 - 103
  • [34] Liquid chromatography/negative electrospray ionization ion trap MS2 mass spectrometry application for the determination of microcystins occurrence in Southern Portugal water reservoirs
    Rodrigues, M. A.
    Reis, M. P.
    Mateus, M. C.
    TOXICON, 2013, 74 : 8 - 18
  • [35] Development of an Ultrahigh-Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for the Simultaneous Determination of Salicylic Acid, Jasmonic Acid, and Abscisic Acid in Rose Leaves
    Bosco, Renato
    Daeseleire, Els
    Van Pamel, Els
    Scariot, Valentina
    Leus, Leen
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (27) : 6278 - 6284
  • [36] Determination of acyclovir in horse plasma and body fluids by high-performance liquid chromatography combined with fluorescence detection and heated electrospray ionization tandem mass spectrometry
    Maes, A.
    Garre, B.
    Desmet, N.
    van der Meulen, K.
    Nauwynck, H.
    De Backer, P.
    Croubels, S.
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (02) : 132 - 140
  • [37] Determination of biocides in different environmental matrices by use of ultra-high-performance liquid chromatography-tandem mass spectrometry
    Chen, Zhi-Feng
    Ying, Guang-Guo
    Lai, Hua-Jie
    Chen, Feng
    Su, Hao-Chang
    Liu, You-Sheng
    Peng, Fu-Qiang
    Zhao, Jian-Liang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (10) : 3175 - 3188
  • [38] Quantification of piperazine phosphate in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry employing precolumn derivatization with dansyl chloride
    Lin, Hui
    Tian, Yuan
    Zhang, Zunjian
    Wu, Lili
    Chen, Yun
    ANALYTICA CHIMICA ACTA, 2010, 664 (01) : 40 - 48
  • [39] Determination of synthetic phenolic antioxidants and relative metabolites in sewage treatment plant and recipient river by high performance liquid chromatography-electrospray tandem mass spectrometry
    Liu, Runzeng
    Ruan, Ting
    Song, Shanjun
    Lin, Yongfeng
    Jiang, Guibin
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1381 : 13 - 21
  • [40] Optimization of the Extraction of Anthocyanins from the Fruit Skin of Rhodomyrtus tomentosa (Ait.) Hassk and Identification of Anthocyanins in the Extract Using High-Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometry (HPLC-ESI-MS)
    Liu, Guo-Ling
    Guo, Hong-Hui
    Sun, Yuan-Ming
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2012, 13 (05) : 6292 - 6302