Determination of putrescine, cadaverine, spermidine and spermine in different chemical matrices by high performance liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (HPLC-ESI-ITMS/MS)

被引:28
|
作者
Gonzalez Ibarra, Alan Alexander [1 ]
Wrobel, Katarzyna [1 ]
Corrales Escobosa, Alma Rosa [1 ]
Torres Elguera, Julio Cesar [1 ]
Eugenia Garay-Sevilla, Ma [2 ]
Wrobel, Kazimierz [1 ]
机构
[1] Univ Guanajuato, Dept Chem, Guanajuato 36000, Mexico
[2] Univ Guanajuato, Dept Med Sci, Guanajuato 36000, Mexico
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2015年 / 1002卷
关键词
Aliphatic polyamines; 4-fluoro-3-nitrobenzenotrifluoride (FNBT); LC-MS; Multiple reaction monitoring; Plant abiotic stress; Diabetes; Urine; SOLID-PHASE EXTRACTION; BIOGENIC-AMINES; HUMAN URINE; LEPIDIUM-SATIVUM; CADMIUM STRESS; POLYAMINES; DERIVATIZATION; SAMPLES; FOODS; DERIVATIVES;
D O I
10.1016/j.jchromb.2015.08.036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The goal of this work was to establish a simple HPLC-ESI-ITMS/MS procedure, suitable for the determination of four common aliphatic polyamines in two different types of biological matrices. To this end, 1,6-diaminohexane was used as the internal standard (IS) and 4-fluoro-3-nitrobenzenotrifluoride (FNBT) as the derivatizing agent. Formation of fully derivatized compounds was confirmed by high resolution ESI-QTOFMS and MS/MS analysis. Reversed phase chromatographic separation was carried out by gradient elution with 0.1% (v/v) formic acid and methanol. In a positive ESI mode, the following pairs of precursor/quantifier ions were used for multiple reaction monitoring: 467.4/261.0 for PUT, 481.2/461.1 for CAD, 713.7/261.0 for SPD, 959.8/507.2 for SPM and 495.3/475.2 for IS. On-column instrumental detection limits of four polyamines were in the range 0.62-2.14 fmol (0.039-0.215 ng/ml). Versatility was demonstrated by analyzing plant extracts and human urine; prior to derivatization, all samples were cleaned-up by dichloromethane extraction. The evaluated signal suppression/enhancement was in the range 82.3-115.4% and the percentage recoveries obtained in the method of standard addition were in the range 817-114.4%. Statistically significant differences in polyamines concentrations were found in garden cress exposed to Cd(II) versus control seedlings (t-test, p < 0.05); results obtained for urine from healthy volunteers and diabetic patients at different clinical conditions suggested possible utility of free polyamines as biomarkers of progressive diabetes. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 184
页数:9
相关论文
共 50 条
  • [1] Determination of tetrabromobisphenol-A in soil by high performance liquid chromatography-electrospray ion trap mass spectrometry
    Peng Hao
    Jin Jun
    Wang Ying
    Liu Wei-Zhi
    Yang Ruo-Ming
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (04) : 549 - 551
  • [2] Determination of phosphatidylethanolamine molecular species in various food matrices by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS2)
    Zhou, Li
    Zhao, Minjie
    Ennahar, Said
    Bindler, Francoise
    Marchioni, Eric
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (01) : 291 - 300
  • [3] Simultaneous determination of 24 or more acidic and alkaline phytohormones in femtomole quantities of plant tissues by high-performance liquid chromatography-electrospray ionization-ion trap mass spectrometry
    Liu, Shichang
    Chen, Weiqi
    Qu, Long
    Gai, Ying
    Jiang, Xiangning
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (04) : 1257 - 1266
  • [4] Simple and rapid determination of biogenic amines in wine by liquid chromatography-electrospray ionization ion trap mass spectrometry
    Millan, Silvia
    Sampedro, M. Carmen
    Unceta, Nora
    Goicolea, M. Aranzazu
    Barrio, Ramon J.
    ANALYTICA CHIMICA ACTA, 2007, 584 (01) : 145 - 152
  • [5] Determination of isotretinoin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry
    Wu, Lili
    Wu, Jingjing
    Zhou, Ke
    Cheng, Fang
    Chen, Yun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (02) : 324 - 329
  • [6] An assay for identification and determination of toxic rodenticide valone in serum by ion chromatography-electrospray ionization tandem mass spectrometry with ion trap detector
    Cai, Mei-Qiang
    Dong, Xin-Yan
    Chen, Xiao-Hong
    Jin, Mi-Cong
    TALANTA, 2009, 78 (01) : 242 - 247
  • [7] Development of a method for comprehensive and quantitative analysis of plant hormones by highly sensitive nanoflow liquid chromatography-electrospray ionization-ion trap mass spectrometry
    Izumi, Yoshihiro
    Okazawa, Atsushi
    Bamba, Takeshi
    Kobayashi, Akio
    Fukusaki, Eiichiro
    ANALYTICA CHIMICA ACTA, 2009, 648 (02) : 215 - 225
  • [8] Simultaneous determination of human and veterinary antibiotics in various environmental matrices by rapid resolution liquid chromatography-electrospray ionization tandem mass spectrometry
    Zhou, Li-Jun
    Ying, Guang-Guo
    Liu, Shan
    Zhao, Jian-Liang
    Chen, Feng
    Zhang, Rui-Quan
    Peng, Fu-Qiang
    Zhang, Qian-Qian
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 123 - 138
  • [9] ULTRA-HIGH PERFORMANCE LIQUID CHROMATOGRAPHY WITH ELECTROSPRAY IONIZATION TANDEM MASS SPECTROMETRY FOR THE DETERMINATION OF CAFFEINE IN ENERGY DRINKS
    Lee, Min Soo
    Nguyen Lan Huong
    Nguyen Huu Hoang
    Shrestha, Anil
    Park, Je Won
    ANALYTICAL LETTERS, 2014, 47 (11) : 1852 - 1861
  • [10] A simple and selective method for determination of phthalate biomarkers in vegetable samples by high pressure liquid chromatography-electrospray ionization-tandem mass spectrometry
    Zhou, Xi
    Cui, Kunyan
    Zeng, Feng
    Li, Shoucong
    Zeng, Zunxiang
    FOOD CHEMISTRY, 2016, 200 : 336 - 342