Estimation of multivariate detection limits of four quality parameters in licorice using MEMS-NIR spectrometry coupled with two sampling accessories

被引:0
作者
Wu, Zhisheng [1 ]
Shi, Xinyuan
Zhao, Na
Pei, Yanling
Xu, Manfei
Zhou, Luwei
Li, Yang
Qiao, Yanjiang
机构
[1] Beijing Univ Chinese Med, Beijing 100102, Peoples R China
基金
中国国家自然科学基金;
关键词
Near-infrared spectrometer; multivariate detection limits; sampling accessories; licorice; partial least squares regression; NEAR-INFRARED SPECTROSCOPY; PROCESS ANALYTICAL-CHEMISTRY; CALIBRATION; TABLETS; TRANSMISSION; UNIFORMITY; FIGURES; MODELS; ERROR; PROBE;
D O I
10.1142/S1793545815500091
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, multivariate detection limits (MDL) estimator was obtained based on the microelectro-mechanical systems-near infrared (MEMS-NIR) technology coupled with two sampling accessories to assess the detection capability of four quality parameters (glycyrrhizic acid, liquiritin, liquiritigenin and isoliquiritin) in licorice from different geographical regions. 112 licorice samples were divided into two parts (calibration set and prediction set) using Kennard-Stone (KS) method. Four quality parameters were measured using high-performance liquid chromatography (HPLC) method according to Chinese pharmacopoeia and previous studies. The MEMS-NIR spectra were acquired from fiber optic probe (FOP) and integrating sphere, then the partial least squares (PLS) model was obtained using the optimum processing method. Chemometrics indicators have been utilized to assess the PLS model performance. Model assessment using chemometrics indicators is based on relative mean prediction error of all concentration levels, which indicated relatively low sensitivity for low-content analytes (below 1000 parts per million (ppm)). Therefore, MDL estimator was introduced with alpha error and beta error based on good prediction characteristic of low concentration levels. The result suggested that MEMS-NIR technology coupled with fiber optic probe (FOP) and integrating sphere was able to detect minor analytes. The result further demonstrated that integrating sphere mode (i.e., MDL0.05,0.05, 0.22%) was more robust than FOP mode (i.e., MDL0.05,0.05, 0.48%). In conclusion, this research proposed that MDL method was helpful to determine the detection capabilities of low-content analytes using MEMS-NIR technology and successful to compare two sampling accessories.
引用
收藏
页数:10
相关论文
共 25 条
  • [12] Near-infrared spectroscopy applications in pharmaceutical analysis
    Luypaert, J.
    Massart, D. L.
    Heyden, Y. Vander
    [J]. TALANTA, 2007, 72 (03) : 865 - 883
  • [13] 204 years of near infrared technology: 1800-2003
    McClure, WF
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2003, 11 (06) : 487 - 518
  • [14] Detection limit estimator for multivariate calibration by an extension of the IUPAC recommendations for univariate methods
    Ostra, Miren
    Ubide, Carlos
    Vidal, Maider
    Zuriarrain, Juan
    [J]. ANALYST, 2008, 133 (04) : 532 - 539
  • [15] Near infrared spectroscopy in the development of solid dosage forms
    Rasanen, Eetu
    Sandler, Niklas
    [J]. JOURNAL OF PHARMACY AND PHARMACOLOGY, 2007, 59 (02) : 147 - 159
  • [16] A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
    Roggo, Yves
    Chalus, Pascal
    Maurer, Lene
    Lema-Martinez, Carmen
    Edmond, Aurelie
    Jent, Nadine
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 683 - 700
  • [17] The use of net analyte signal (NAS) in near infrared spectroscopy pharmaceutical applications: Interpretability and figures of merit
    Sarraguca, Mafalda Cruz
    Lopes, Joao Almeida
    [J]. ANALYTICA CHIMICA ACTA, 2009, 642 (1-2) : 179 - 185
  • [18] MULTIVARIATE DECISION AND DETECTION LIMITS
    SINGH, A
    [J]. ANALYTICA CHIMICA ACTA, 1993, 277 (02) : 205 - 214
  • [19] A review of near infrared spectroscopy in muscle food analysis: 2005-2010
    Weeranantanaphan, Jittima
    Downey, Gerard
    Allen, Paul
    Sun, Da-Wen
    [J]. JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2011, 19 (02) : 61 - 104
  • [20] Process Analytical Chemistry
    Workman, Jerome, Jr.
    Lavine, Barry
    Chrisman, Ray
    Koch, Mel
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (12) : 4557 - 4578