Estimation of multivariate detection limits of four quality parameters in licorice using MEMS-NIR spectrometry coupled with two sampling accessories

被引:0
作者
Wu, Zhisheng [1 ]
Shi, Xinyuan
Zhao, Na
Pei, Yanling
Xu, Manfei
Zhou, Luwei
Li, Yang
Qiao, Yanjiang
机构
[1] Beijing Univ Chinese Med, Beijing 100102, Peoples R China
基金
中国国家自然科学基金;
关键词
Near-infrared spectrometer; multivariate detection limits; sampling accessories; licorice; partial least squares regression; NEAR-INFRARED SPECTROSCOPY; PROCESS ANALYTICAL-CHEMISTRY; CALIBRATION; TABLETS; TRANSMISSION; UNIFORMITY; FIGURES; MODELS; ERROR; PROBE;
D O I
10.1142/S1793545815500091
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, multivariate detection limits (MDL) estimator was obtained based on the microelectro-mechanical systems-near infrared (MEMS-NIR) technology coupled with two sampling accessories to assess the detection capability of four quality parameters (glycyrrhizic acid, liquiritin, liquiritigenin and isoliquiritin) in licorice from different geographical regions. 112 licorice samples were divided into two parts (calibration set and prediction set) using Kennard-Stone (KS) method. Four quality parameters were measured using high-performance liquid chromatography (HPLC) method according to Chinese pharmacopoeia and previous studies. The MEMS-NIR spectra were acquired from fiber optic probe (FOP) and integrating sphere, then the partial least squares (PLS) model was obtained using the optimum processing method. Chemometrics indicators have been utilized to assess the PLS model performance. Model assessment using chemometrics indicators is based on relative mean prediction error of all concentration levels, which indicated relatively low sensitivity for low-content analytes (below 1000 parts per million (ppm)). Therefore, MDL estimator was introduced with alpha error and beta error based on good prediction characteristic of low concentration levels. The result suggested that MEMS-NIR technology coupled with fiber optic probe (FOP) and integrating sphere was able to detect minor analytes. The result further demonstrated that integrating sphere mode (i.e., MDL0.05,0.05, 0.22%) was more robust than FOP mode (i.e., MDL0.05,0.05, 0.48%). In conclusion, this research proposed that MDL method was helpful to determine the detection capabilities of low-content analytes using MEMS-NIR technology and successful to compare two sampling accessories.
引用
收藏
页数:10
相关论文
共 25 条
  • [1] Analysis of Low Content Drug Tablets by Transmission Near Infrared Spectroscopy: Selection of Calibration Ranges According to Multivariate Detection and Quantitation Limits of PLS Models
    Alcala, Manel
    Leon, Joshua
    Ropero, Jorge
    Blanco, Marcelo
    Romanach, Rodolfo J.
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 2008, 97 (12) : 5318 - 5327
  • [2] [Anonymous], 2010, PHARM PEOPLES REPUBL
  • [3] Bauer G., 1991, J ANAL CHEM+, V340, P135
  • [4] Detection limits in classical multivariate calibration models
    Boqué, R
    Faber, NKM
    Rius, FX
    [J]. ANALYTICA CHIMICA ACTA, 2000, 423 (01) : 41 - 49
  • [5] Multivariate detection limits with fixed probabilities of error
    Boqué, R
    Larrechi, MS
    Rius, FX
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 45 (1-2) : 397 - 408
  • [6] Multivariate detection limits estimators
    Boque, R
    Rius, FX
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (01) : 11 - 23
  • [7] Faber K., 1997, J ANAL CHEM+, V357, P789
  • [8] Use of a Fiber-Optic Turbidity Probe to Monitor and Control Commercial-Scale Unseeded Batch Crystallizations
    Harner, Richard S.
    Ressler, Roberta J.
    Briggs, Roger L.
    Hitt, James E.
    Larsen, Paul A.
    Frank, Timothy C.
    [J]. ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2009, 13 (01) : 114 - 124
  • [9] Using scattering and absorption spectra as MCR-hard model constraints for diffuse reflectance measurements of tablets
    Kessler, Waltraud
    Oelkrug, Dieter
    Kessler, Rudolf
    [J]. ANALYTICA CHIMICA ACTA, 2009, 642 (1-2) : 127 - 134
  • [10] Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe
    Li, Weiyong
    Johnson, Mark C.
    Bruce, Rick
    Ulrich, Steven
    Rasmussen, Henrik
    Worosila, Gregory D.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2006, 326 (1-2) : 182 - 185