Comparison of Contrast Sensitivity and Through Focus in Small-Aperture Inlay, Accommodating Intraocular Lens, or Multifocal Intraocular Lens Subjects

被引:35
|
作者
Vilupuru, Srividhya [1 ]
Lin, Ling [1 ]
Pepose, Jay S. [2 ,3 ]
机构
[1] AcuFocus Inc, Irvine, CA USA
[2] Washington Univ, Sch Med, Pepose Vis Inst, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
INTRACORNEAL INLAY; SURGICAL-CORRECTION; CLINICAL-EVALUATION; VISUAL PERFORMANCE; PRESBYOPIA; CATARACT; OUTCOMES; DECLINE; ACUITY;
D O I
10.1016/j.ajo.2015.04.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare monocular and binocular mesopic contrast sensitivity and through focus following monocular implantation with KAMRA small-aperture inlay (AcuFocus, Irvine, California, USA) vs binocular implantation with an accommodating or multifocal intraocular lens (IOL) implant. DESIGN: Three-treatment randomized clinical trial of presbyopia-correcting IOLs with comparison to results from a previous nonrandomized multicenter clinical trial on the KAMRA corneal inlay. METHODS: Study population of 507 subjects with KAMRA inlays; predetermined subgroups included 327 subjects that underwent contrast sensitivity testing and another 114 subjects for defocus curve testing, along with 78 subjects randomized between bilateral Crystalens Advanced Optics (AO) (Bausch + Lomb Surgical, Aliso Viejo, California, USA), AcrySof IQ ReSTOR +3.0 D (Alcon Laboratories, Fort Worth, Texas, USA), or Tecnis + 4D Multifocal (MF) (Abbott Medical Optics, Santa Ana, California, USA) IOL. RESULTS: KAMRA inlay subjects demonstrated improved intermediate and near vision with minimal to no change to distance vision, better contrast sensitivity in the inlay eye when compared to the multifocals, and better binocular contrast sensitivity when compared to all 3 intraocular lenses. Crystalens AO was superior in uncorrected intermediate vision compared to the KAMRA inlay, but not in distance-corrected intermediate, and was worse in near vision. The multifocals were superior in near vision at their respective optimum near focus points, but worse in intermediate vision compared to both KAMRA inlay and Crystalens AO. CONCLUSIONS: The demonstrated performance of these devices should be considered, along with subjects' visual demands and expectations, degree of crystalline lens dysfunction, and other ocular characteristics, in guiding the selection of small-aperture corneal inlay or specific intraocular lens in the correction of presbyopia. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:150 / 162
页数:13
相关论文
共 50 条
  • [31] Predictability of Refractive Outcome of a Small-Aperture Intraocular Lens in Eyes With Irregular Corneal Astigmatism
    Langer, Julian
    Shajari, Mehdi
    Kreutzer, Thomas
    Priglinger, Siegfried
    Mayer, Wolfgang J.
    Mackert, Marc J.
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (05) : 312 - +
  • [32] Impact of posterior vitreous detachment on contrast sensitivity in patients with multifocal intraocular lens
    Mano, Fukutaro
    LoBue, Stephen A.
    Eno, Ayako
    Chang, Kuo-Chung
    Mano, Tomiya
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (08) : 1709 - 1716
  • [33] Impact of posterior vitreous detachment on contrast sensitivity in patients with multifocal intraocular lens
    Fukutaro Mano
    Stephen A. LoBue
    Ayako Eno
    Kuo-Chung Chang
    Tomiya Mano
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1709 - 1716
  • [34] Distance and near contrast sensitivity function after multifocal intraocular lens implantation
    Montés-Micó, R
    Alió, JL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 703 - 711
  • [35] Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12): : 2043 - 2048
  • [36] Moderate monovision with monofocal intraocular lenses vs mini-monovision with a small-aperture intraocular lens: a comparative analysis
    Bezerra, Bernardo de Padua Soares
    Beltz, Jacqueline
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 46 - 46
  • [37] Effects of tinted intraocular lens on contrast sensitivity
    Niwa, K
    Yoshino, Y
    Okuyama, F
    Tokoro, T
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1996, 16 (04) : 297 - 302
  • [38] An objective method to measure astigmatism tolerance with a small-aperture vs. monofocal intraocular lens
    Thomas, Eugenia Kao
    Lin, Ling
    Vilupuru, Srividhya
    Ang, Robert
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [39] Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus
    Nio, YK
    Jansonius, NM
    Geraghty, E
    Norrby, S
    Kooijman, AC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11): : 2073 - 2081
  • [40] Satisfaction, contrast sensitivity and optical aberrations following multifocal intraocular lens insertion.
    Brunette, I
    Hamam, H
    Fontaine, N
    Beyrouthy, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S9 - S9