Low noise thermistor readout for wideband room temperature infrared detectors

被引:0
|
作者
Ryger, Ivan [1 ]
Harber, Dave [3 ]
Stephens, Michelle [1 ]
White, Malcolm [1 ]
Tomlin, Nathan [1 ]
Spidell, Matthew [1 ]
Lobotka, Peter [2 ]
Lehman, John [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] Slovak Acad Sci, Inst Elect Engn, Bratislava 84104, Slovakia
[3] Atmospher & Space Phys Lab, Boulder, CO 80303 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An absolute electrical substitution radiometer is a way to ensure highly accurate and stable measurement of optical power in a wide range of optical wavelengths. Its sensitivity is mainly determined by the temperature stability of the equithermal bath and the electrical noise of the temperature readout. In this article we investigate the noise background of different preamplifiers in combination with different types of temperature sensors. The 1/f noise of temperature sensors and Johnson thermal noise of preamplifiers were chosen as a figure of merit. The results from our measurements are discussed.
引用
收藏
页数:2
相关论文
共 50 条
  • [21] Indium Bump Process for Low-Temperature Detectors and Readout
    T. J. Lucas
    J. P. Biesecker
    W. B. Doriese
    S. M. Duff
    G. C. Hilton
    J. N. Ullom
    M. R. Vissers
    D. R. Schmidt
    Journal of Low Temperature Physics, 2022, 209 : 293 - 298
  • [22] Low noise amplifier design and low noise amplifiers for characterizing the low frequency noise of infrared detectors
    Howard, R.M.
    Conference on Optoelectronic and Microelectronic Materials and Devices, Proceedings, COMMAD, 1998, : 179 - 182
  • [23] Integrated infrared detectors and readout circuits
    Cairns, John W.
    Buckle, Louise
    Pryce, Graham J.
    Hails, Janet E.
    Giess, Jean
    Crouch, Mark A.
    Hall, David J.
    Hydes, Alan
    Graham, Andrew
    Wright, Andrew J.
    Hollier, Colin J.
    Lees, David J.
    Gordon, Neil T.
    Ashley, Timothy
    INFRARED TECHNOLOGY AND APPLICATIONS XXXII, PTS 1AND 2, 2006, 6206
  • [24] Low-noise readout circuit for uncooled infrared FPA
    Tanaka, A
    Chiba, K
    Endoh, T
    Okuyama, K
    Kawahara, A
    Iida, K
    Tsukamoto, N
    INFRARED TECHNOLOGY AND APPLICATIONS XXVI, 2000, 4130 : 160 - 167
  • [25] Room-temperature YBaCuO infrared detectors on a flexible substrate
    Çelik-Butler, Z
    Butler, DP
    Yildiz, A
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS VII, 2002, 4721 : 260 - 268
  • [26] THERMAL VERSUS QUANTUM ROOM-TEMPERATURE INFRARED DETECTORS
    KARASIKOV, N
    ROITBERG, MB
    INFRARED PHYSICS, 1981, 21 (06): : 333 - 335
  • [27] Low temperature thermoelectric coolers for infrared detectors
    Phong, LN
    Shih, I
    INFRARED TECHNOLOGY AND APPLICATIONS XXIV, PTS 1-2, 1998, 3436 : 824 - 831
  • [28] Performance of position sensitive scintillator detectors when readout with a low noise photodevice
    Labanti, C.
    Marisaldi, M.
    Fuschino, F.
    Galli, M.
    Mauri, A.
    Negri, B.
    Perotti, F.
    Soltau, H.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 23 - +
  • [29] OLA, a low-noise bipolar amplifier for the readout of silicon drift detectors
    Dabrowski, W
    Bialas, W
    Bonazzola, G
    Bonvicini, V
    Ceretto, F
    Giubellino, P
    Idzik, M
    Prest, M
    Riccati, L
    Zampa, N
    NUCLEAR PHYSICS B, 1995, : 637 - 641
  • [30] Preparation of multilayer barium titanate PTC thermistor with low room temperature resistance
    Zhou, DX
    Liu, H
    Gong, SP
    Zhang, DL
    HIGH-PERFORMANCE CERAMICS III, PTS 1 AND 2, 2005, 280-283 : 1921 - 1924