Low noise thermistor readout for wideband room temperature infrared detectors

被引:0
|
作者
Ryger, Ivan [1 ]
Harber, Dave [3 ]
Stephens, Michelle [1 ]
White, Malcolm [1 ]
Tomlin, Nathan [1 ]
Spidell, Matthew [1 ]
Lobotka, Peter [2 ]
Lehman, John [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
[2] Slovak Acad Sci, Inst Elect Engn, Bratislava 84104, Slovakia
[3] Atmospher & Space Phys Lab, Boulder, CO 80303 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An absolute electrical substitution radiometer is a way to ensure highly accurate and stable measurement of optical power in a wide range of optical wavelengths. Its sensitivity is mainly determined by the temperature stability of the equithermal bath and the electrical noise of the temperature readout. In this article we investigate the noise background of different preamplifiers in combination with different types of temperature sensors. The 1/f noise of temperature sensors and Johnson thermal noise of preamplifiers were chosen as a figure of merit. The results from our measurements are discussed.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] THERMISTOR INFRARED DETECTORS
    ASTHEIMER, RW
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 443 : 95 - 109
  • [2] Design of a low noise and high accuracy readout integrated circuit for Infrared detectors
    Yang Dong
    Zhou Hang-yu
    Wang Jian
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN INFRARED IMAGING AND APPLICATIONS, 2011, 8193
  • [3] PROPERTIES OF THERMISTOR INFRARED DETECTORS
    WORMSER, EM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (01) : 15 - 21
  • [4] LOW-NOISE ROOM-TEMPERATURE WIDEBAND PARAMETRIC AMPLIFIERS
    VOKES, JC
    DAWSEY, JR
    DEADMAN, HA
    ELECTRONICS LETTERS, 1971, 7 (22) : 657 - &
  • [5] Infrared detectors with high fill-factor absorber and low offset low noise readout circuit
    Huang Zhuo-Lei
    Wang Wei-Bing
    Jiang Wen-Jing
    Ou Wen
    Ming An-Jie
    Liu Zhan-Feng
    Chen Da-Peng
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2014, 33 (01) : 50 - +
  • [6] Low noise JFETs for room temperature x-ray detectors
    Lund, MW
    Decker, KW
    Perkins, RT
    Phillips, JD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 318 - 322
  • [7] Low noise JFETs for room temperature x-ray detectors
    Lund, Mark W.
    Decker, Keith W.
    Perkins, Raymond T.
    Phillips, James D.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 380 (1-2): : 318 - 322
  • [8] A Low Noise Readout ASIC for CdTe/CdZnTe Detectors
    Luo, Jie
    Deng, Zhi
    Liu, Yinong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3804 - 3807
  • [9] LOW-NOISE SILICON PLANAR DETECTORS FOR ROOM-TEMPERATURE APPLICATION
    KEIL, G
    LINDNER, E
    NUCLEAR INSTRUMENTS & METHODS, 1972, 104 (01): : 209 - &
  • [10] Ionization Readout of CDMS Detectors with Low Power, Low Noise HEMTs
    Phipps, A.
    Jin, Y.
    Sadoulet, B.
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2014, 176 (3-4) : 470 - 475