High Sensitivity of Diffusion-weighted MR Imaging for the Detection of Liver Metastases from Neuroendocrine Tumors: Comparison with T2-weighted and Dynamic Gadolinium-enhanced MR Imaging

被引:149
作者
d'Assignies, Gaspard [1 ,5 ]
Fina, Priscilla [1 ]
Bruno, Onorina [1 ]
Vullierme, Marie-Pierre [1 ]
Tubach, Florence [6 ]
Paradis, Valerie [2 ,5 ]
Sauvanet, Alain [3 ]
Ruszniewski, Philippe [4 ,5 ]
Vilgrain, Valerie [1 ,5 ]
机构
[1] Hop Beaujon, AP HP, Dept Radiol, F-92110 Clichy, France
[2] Hop Beaujon, AP HP, Dept Pathol, F-92110 Clichy, France
[3] Hop Beaujon, AP HP, Dept Hepatobiliary Surg, F-92110 Clichy, France
[4] Hop Beaujon, AP HP, Dept Gastroenterol, F-92110 Clichy, France
[5] Univ Paris Diderot, Sorbonne Paris Cite, INSERM, CRB3 U773,Ctr Rech Biomed Bichat Beaujon, Paris, France
[6] Hop Bichat Claude Bernard, AP HP, Clin Res Unit, F-75877 Paris, France
关键词
HEPATIC METASTASES; SPIN-ECHO; LESION DETECTION; STANDARD; GUIDELINES; DIAGNOSIS;
D O I
10.1148/radiol.13121628
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the sensitivity and specificity of diffusion-weighted (DW) magnetic resonance (MR) imaging for identifying liver metastases from neuroendocrine tumor (NET) to those of T2-weighted fast spin-echo (FSE) and three-dimensional dynamic gadolinium-enhanced MR imaging, with surgical and histopathologic findings as the reference standard. Materials and Methods: This retrospective study was approved by institutional review board, and informed consent was waived. Fifty-nine patients with NETs (41 patients with 162 liver metastases, and 18 control subjects with no liver metastases) underwent MR imaging that included DW, T2-weighted FSE, and dynamic gadolinium-enhanced MR sequences. Images were retrospectively reviewed by two abdominal radiologists, independently, for the detection and characterization of liver metastases. MR findings were compared with histopathologic and intraoperative ultrasonography findings for metastasis on a lesion-by-lesion basis to determine the sensitivity of each MR sequence alone and combined. Specificity was calculated by using the control population. Interreader agreement for each MR sequence and McNemar test were also calculated. Results: There was excellent agreement between observers 1 and 2 for characterizing liver metastases at per-lesion analysis (kappa coefficient: 0.86-1.00). DW MR was more sensitive (observer 1: sensitivity, 71.6% [116 of 162], 95% confidence interval [CI]: 64.2%, 78.0%; observer 2: sensitivity, 71.0% [115 of 162], 95% CI: 63.6%, 77.4%) than T2-weighted FSE (observer 1: sensitivity, 55.6% [90 of 162], 95% CI: 47.9%, 63.0%; observer 2: sensitivity, 55.6% [90 of 162], 95% CI: 47.9%, 63.0%) and dynamic gadolinium-enhanced MR (observer 1: sensitivity, 47.5% [77 of 162], 95% CI: 34.0%, 55.2%; observer 2: sensitivity, 48.1% [78 of 162], 95% CI: 40.6%, 55.8%) (P < .001 for both, McNemar test). The specificity of these sequences ranged from 88.9% to 100% (DW MR vs T2-weighted FSE MR: P > .99, DW MR vs dynamic gadolinium-enhanced MR: P = .61, and T2-weighted FSE MR vs dynamic gadolinium-enhanced MR: P = .61, McNemar test). Conclusion: DW MR imaging was more sensitive for the detection and characterization of liver metastases from NETs than T2-weighted FSE and dynamic gadolinium-enhanced MR imaging and should be systematically performed. (c) RSNA, 2013
引用
收藏
页码:390 / 399
页数:10
相关论文
共 22 条
[1]   ENETS Consensus Guidelines for the Standards of Care in Neuroendocrine Tumors: Pre- and Perioperative Therapy in Patients with Neuroendocrine Tumors [J].
Akerstrom, Goran ;
Falconi, Massimo ;
Kianmanesh, Reza ;
Ruszniewski, Philippe ;
Ploeckinger, Ursula .
NEUROENDOCRINOLOGY, 2009, 90 (02) :203-208
[2]   Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations [J].
不详 .
NEOPLASIA, 2009, 11 (02) :102-125
[3]   Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences [J].
Bruegel, Melanie ;
Gaa, Jochen ;
Waldt, Simone ;
Woertler, Klaus ;
Holzapfel, Konstantin ;
Kiefer, Berthold ;
Rummeny, Ernst J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) :1421-1429
[4]   Improved focal liver lesion detection:: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques [J].
Coenegrachts, K. ;
Delanote, J. ;
Ter Beek, L. ;
Haspeslagh, M. ;
Bipat, S. ;
Stoker, J. ;
Van Kerkhove, F. ;
Steyaert, L. ;
Rigauts, H. ;
Casselman, J. W. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (955) :524-531
[5]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[6]   Detection of liver metastases from endocrine tumors: A prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging [J].
Dromain, C ;
de Baere, T ;
Lumbroso, J ;
Caillet, H ;
Laplanche, AS ;
Boige, V ;
Ducreux, M ;
Duvillard, P ;
Elias, D ;
Schlumberger, M ;
Sigal, R ;
Baudin, E .
JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (01) :70-78
[7]   MR imaging of hepatic metastases caused by neuroendocrine tumors: Comparing four techniques [J].
Dromain, C ;
de Baere, T ;
Baudin, E ;
Galline, J ;
Ducreux, M ;
Boige, V ;
Duvillard, P ;
Laplanche, A ;
Caillet, H ;
Lasser, P ;
Schlumberger, M ;
Sigal, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (01) :121-128
[8]   Hepatic Metastases From Neuroendocrine Tumors With a "Thin Slice" Pathological Examination They are Many More Than You Think ... [J].
Elias, Dominique ;
Lefevre, Jereme H. ;
Duvillard, Pierre ;
Goere, Diane ;
Dromain, Clarisse ;
Dumont, Frederic ;
Baudin, Eric .
ANNALS OF SURGERY, 2010, 251 (02) :307-310
[9]   Diffusion-Weighted Magnetic Resonance Imaging for Characterization of Focal Liver Masses: Impact of Parallel Imaging (SENSE) and b Value [J].
Erturk, Sukru Mehmet ;
Ichikawa, Tomoaki ;
Sano, Katsuhiro ;
Motosugi, Utarou ;
Sou, Hironobu ;
Araki, Tsutomu .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (06) :865-871
[10]   Diagnosis of liver metastases: value of diffusion-weighted MRI compared with gadolinium-enhanced MRI [J].
Hardie, Andrew D. ;
Naik, Mohit ;
Hecht, Elizabeth M. ;
Chandarana, Hersh ;
Mannelli, Lorenzo ;
Babb, James S. ;
Taouli, Bachir .
EUROPEAN RADIOLOGY, 2010, 20 (06) :1431-1441