Determination of free amino acids in plants by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)

被引:22
作者
Dziagwa-Becker, Magdalena M. [1 ]
Marin Ramos, Jose M. [2 ]
Topolski, Jakub K. [1 ]
Oleszek, Wieslaw A. [3 ]
机构
[1] State Res Inst, Dept Weed Sci & Tillage Syst, Inst Soil Sci & Plant Cultivat, PL-50540 Wroclaw, Poland
[2] Univ Jaume 1, Res Inst Pesticides & Water, Castellon de La Plana, Spain
[3] State Res Inst, Dept Biochem & Crop Qual, Inst Soil Sci & Plant Cultivat, Pulawy, Poland
关键词
QUANTIFICATION; DIPEPTIDES;
D O I
10.1039/c5ay01280e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust and sensitive method for identification (quantification and confirmation) of 19 free amino acids in the plant matrix, Stellaria media, based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS), with a triple quadrupole analyser, has been developed. Regarding MS optimization, flow injection analysis (FIA) was used in scan and selected reaction monitoring (SRM) mode. The collision energies optimized varied from -12 to -39 eV. The acquisition of three MS/MS transitions for most of the compounds allowed the accurate confirmation of these analytes, which was supported by the accomplishment of ion intensity ratios and retention time as compared with the corresponding standards. The use of a Phenomenex EZ:faast (TM) Free (Physiological) Amino Acid kit speeds up the sample preparation immeasurably. Nineteen amino acids were separated within 18 minutes on a reverse-phase column under a gradient stepwise programme using 10 mM ammonium formate both in water and methanol. The detection limit (LOD) for free amino acids varied from 0.4 to 9.1 pmol mL(-1), except for asparagine amounting to 3000 pmol mL(-1). The quantification precision (RSD) of free amino acids for intra-and interday assays was 0.05-19% and 0.2-19%, respectively, but for most of the compounds, it did not exceed 5%. The optimized and validated method was subsequently utilized for free amino acid identification in weed collected from field locations in Poland.
引用
收藏
页码:7574 / 7581
页数:8
相关论文
共 28 条
  • [1] [Anonymous], 2013, Dzika Kuchnia
  • [2] [Anonymous], PHEN EZ FAAST AM SAM
  • [3] [Anonymous], 2005, VAL AN PROC TEXT MET, V1994
  • [4] Supercritical fluid extraction of free amino acids from broccoli leaves
    Arnaiz, E.
    Bernal, J.
    Martin, M. T.
    Nozal, M. J.
    Bernal, J. L.
    Toribio, L.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1250 : 49 - 53
  • [5] Application of the Phenomenex EZ:faast™ amino acid analysis kit for rapid gas-chromatographic determination of concentrations of plasma tryptophan and its brain uptake competitors
    Badawy, A. A. -B.
    Morgan, C. J.
    Turner, J. A.
    [J]. AMINO ACIDS, 2008, 34 (04) : 587 - 596
  • [6] Bankowski C., 1972, CHWASTACH ICH ZASTOS
  • [7] BERG JM, 2002, BIOCHEMISTRY-US, P639
  • [8] Boulton A. A., 1985, AMINO ACIDS, V3
  • [9] Quantification of free amino acids and dipeptides using isotope dilution liquid chromatography and electrospray ionization tandem mass spectrometry
    Fonteh, A. N.
    Harrington, R. J.
    Harrington, M. G.
    [J]. AMINO ACIDS, 2007, 32 (02) : 203 - 212
  • [10] Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples
    Hernández, F
    Sancho, JV
    Pozo, OJ
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (04) : 934 - 946