Comparison of optic area measurement using fundus photography and Optical Coherence Tomography between optic nerve head drusen and control subjects

被引:13
作者
Flores-Rodriguez, Patricia [1 ,2 ]
Gili, Pablo [1 ,3 ]
Dolores Martin-Rios, Maria [4 ]
Grifol-Clar, Eulalia [5 ]
机构
[1] Alcorcon Fdn Univ Hosp, Ophthalmol Unit, Madrid, Spain
[2] Pontificia Univ Catolica Valparaiso, Valparaiso, Chile
[3] European Univ Madrid, Fac Hlth Sci, Madrid, Spain
[4] Rey Juan Carlos Hosp, Preventat Med Unit, Madrid, Spain
[5] Alcorcon Fdn Univ Hosp, Med Lib Serv, Madrid, Spain
关键词
echography; fundus photography; Optic disc drusen; optic disc; optic nerve head; SCANNING LASER OPHTHALMOSCOPY; STRATUS OCT; SPECTRAL-DOMAIN; DISK SIZE; CLINICAL ANALYSIS; REFRACTIVE ERROR; TIME-DOMAIN; HRT-II; MAGNIFICATION; AGREEMENT;
D O I
10.1111/opo.12017
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. Methods We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20o (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200x200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/MannWhitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Results Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54)mm2 and 2.54 (0.42)mm2, respectively with fundus photography; 2.01 (0.56)mm2 and 1.66 (0.37)mm2, respectively with TD-OCT, and 2.03 (0.49)mm2 and 1.75 (0.38)mm2, respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Conclusions Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques.
引用
收藏
页码:164 / 171
页数:8
相关论文
共 39 条
[1]   Measurements of optic disk size with HRT II, stratus OCT, and funduscopy are not interchangeable [J].
Barkana, Yaniv ;
Harizman, Noga ;
Gerber, Yariv ;
Liebmann, Jeffrey M. ;
Ritch, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (03) :375-380
[2]  
BECK RW, 1984, OPHTHALMOLOGY, V91, P1334
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes [J].
Budenz, DL ;
Chang, RT ;
Huang, XR ;
Knighton, RW ;
Tielsch, JM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2440-2443
[5]  
Chen Teresa C, 2009, Trans Am Ophthalmol Soc, V107, P254
[6]   Ophthalmic Features of Optic Disc Drusen [J].
Flores-Rodriguez, Patricia ;
Gili, Pablo ;
Dolores Martin-Rios, Maria .
OPHTHALMOLOGICA, 2012, 228 (01) :59-66
[7]   Sensitivity and specificity of time-domain and spectral-domain optical coherence tomography in differentiating optic nerve head drusen and optic disc oedema [J].
Flores-Rodriguez, Patricia ;
Gili, Pablo ;
Dolores Martin-Rios, Maria .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (03) :213-221
[8]   Measurement of the scleral canal using optical coherence tomography in patients with optic nerve drusen [J].
Floyd, MS ;
Katz, BJ ;
Digre, KB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (04) :664-669
[9]   Measurement of optic disc size: equivalence of methods to correct for ocular magnification [J].
Garway-Heath, DF ;
Rudnicka, AR ;
Lowe, T ;
Foster, PJ ;
Fitzke, FW ;
Hitchings, RA .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (06) :643-649
[10]  
Gili Manzanaro P, 2004, Arch Soc Esp Oftalmol, V79, P125