Flow structure in critical flow Venturi nozzle and its effect on the flow rate

被引:5
作者
von Lavante, E. [1 ]
Kaya, H. [1 ]
Winzoesch, F. [1 ]
Brinkhorst, S. [1 ]
Mickan, B. [2 ]
机构
[1] Univ Duisburg Essen, Fac Engn, D-47057 Duisburg, Germany
[2] Phys Tech Bundesanstalt, Braunschweig, Germany
关键词
Critical flow Venturi nozzle; Shock structure; Unsteady flow; Discharge coefficient; Unchoking;
D O I
10.1016/j.flowmeasinst.2014.12.003
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The flow fields in toroidal Venturi-nozzles, shaped according to the ISO-9300 Standard, have been investigated using numerical flow simulation. The present study was aimed at clarifying some of the phenomena associated with unchoking the flow in the throat. To this end, the shock structure has been studied for different Reynolds numbers and exit pressure ratios. The flow simulations were carried out in two and three dimensions. The flow fields were always unsteady, displaying a complex shock-boundary layer interaction. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:97 / 106
页数:10
相关论文
共 14 条
  • [1] [Anonymous], 1953, 1135 NACA AM AER LAB
  • [2] Deck Sebastien, 2002, 40 AER SCI M
  • [3] International Standard ISO 9300, 1990, 9300 ISO, Vfirst
  • [4] Mickan B, 2012, P 8 ISFFM C COL JUN
  • [5] Nakao S.-I, 2005, 3 WORKSH CRIT NOZZL
  • [6] Nakao Shin-ichi, 1998, P 9 INT C FLOW MEAS
  • [7] Takamoto M, 2000, FMI, V11, P314
  • [8] von Lavante E, 1992, P 9 GAMM C LAUS NOT
  • [9] von Lavante E, 1998, P 9 INT C FLOW MEAS
  • [10] von Lavante E, 2000, P 10 INT C FLOW MEAS