Measurement of 129Xe gas apparent diffusion coefficient anisotropy in an elastase-instilled rat model of emphysema

被引:32
作者
Boudreau, Mathieu [1 ,2 ,3 ]
Xu, Xiaojun [1 ,2 ,4 ]
Santyr, Giles E. [1 ,5 ,6 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6H 5K8, Canada
[2] Univ Western Ontario, Dept Phys, London, ON N6A 3K7, Canada
[3] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[4] Univ Sheffield, Sheffield, S Yorkshire, England
[5] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
[6] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
hyperpolarized; xenon; 129; lungs; apparent diffusion coefficient anisotropy; emphysema; elastase; low field; FINITE-DIFFERENCE SIMULATIONS; OBSTRUCTIVE PULMONARY-DISEASE; HYPERPOLARIZED NOBLE-GASES; LONG-RANGE DIFFUSION; HE-3; DIFFUSION; MAGNETIC-RESONANCE; HUMAN LUNG; IN-VIVO; FIELD-STRENGTH; RODENT LUNGS;
D O I
10.1002/mrm.24224
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Hyperpolarized noble gas (3He and 129Xe) apparent diffusion coefficient (ADC) measurements have shown remarkable sensitivity to microstructural (i.e., alveolar) changes in the lung, particularly emphysema. The ADC of hyperpolarized noble gases depends strongly on the diffusion time (?), and 3He ADC has been shown to be anisotropic for ? ranging from a few milliseconds down to a few hundred microseconds. In this study, the anisotropic nature of 129Xe diffusion and its dependence on ? were investigated both numerically, in a budded cylinder model, and in vivo, in an elastase-instilled rat model of emphysema. Whole lung longitudinal ADC (DL) and transverse ADC (DT) were measured for ? = 6, 50, and 100 ms at 73.5 mT, and correlated with measurements of the mean linear intercept (Lm) obtained from lung histology. A significant increase (P = 0.0021) in DT was measured for ? = 6 ms between the sham (0.0021 +/- 0.0005 cm2/s) and elastase-instilled (0.005 +/- 0.001 cm2/s) cohorts, and a strong correlation was measured between DT (? = 6 ms) and Lm, with a Pearson's correlation coefficient of 0.90. This study confirms that 129Xe DT increases correlate with alveolar space enlargement due to elastase instillation in rats. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 52 条
[1]   Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold [J].
Abdeen, Nishard ;
Cross, Albert ;
Cron, Gregory ;
White, Steven ;
Rand, Thomas ;
Miller, David ;
Santyr, Giles .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :255-264
[2]   Role of collateral paths in long-range diffusion in lungs [J].
Bartel, Seth-Emil T. ;
Haywood, Susan E. ;
Woods, Jason C. ;
Chang, Yulin V. ;
Menard, Christopher ;
Yablonskiy, Dmitriy A. ;
Gierada, David S. ;
Conradi, Mark S. .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 104 (05) :1495-1503
[3]   Lung fixation for the preservation of air spaces [J].
Blümler, P ;
Acosta, RH ;
Thomas-Semm, A ;
Reuss, S .
EXPERIMENTAL LUNG RESEARCH, 2004, 30 (01) :73-82
[4]   DIFFUSION OF WATER IN THE ENDOSPERM TISSUE OF WHEAT GRAINS AS STUDIED BY PULSED FIELD GRADIENT NUCLEAR MAGNETIC-RESONANCE [J].
CALLAGHAN, PT ;
JOLLEY, KW ;
LELIEVRE, J .
BIOPHYSICAL JOURNAL, 1979, 28 (01) :133-141
[5]  
Chen XJ, 1999, MAGNET RESON MED, V42, P721, DOI 10.1002/(SICI)1522-2594(199910)42:4<721::AID-MRM14>3.0.CO
[6]  
2-D
[7]  
Chronik B, 2000, MAGN RESON MATER PHY, V10, P131
[8]   Hyperpolarized 129Xe MR Imaging of Alveolar Gas Uptake in Humans [J].
Cleveland, Zackary I. ;
Cofer, Gary P. ;
Metz, Gregory ;
Beaver, Denise ;
Nouls, John ;
Kaushik, S. Sivaram ;
Kraft, Monica ;
Wolber, Jan ;
Kelly, Kevin T. ;
McAdams, H. Page ;
Driehuys, Bastiaan .
PLOS ONE, 2010, 5 (08)
[9]   Changes in Regional Airflow Obstruction over Time in the Lungs of Patients with Asthma: Evaluation with 3He MR Imaging [J].
de Lange, Eduard E. ;
Altes, Talissa A. ;
Patrie, James T. ;
Battiston, John J. ;
Juersivich, Adam P. ;
Mugler, John P., III ;
Platts-Mills, Thomas A. .
RADIOLOGY, 2009, 250 (02) :567-575
[10]   Hyperpolarized 3He apparent diffusion coefficient MRI of the lung:: Reproducibility and volume dependency in healthy volunteers and patients with emphysema [J].
Diaz, Sandra ;
Casselbrant, Ingrid ;
Piitulainen, Eeva ;
Pettersson, Goran ;
Magnusson, Peter ;
Peterson, Barry ;
Wollmer, Per ;
Leander, Peter ;
Ekberg, Olle ;
Akeson, Per .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) :763-770