Development of a dispersive liquid-liquid microextraction method for the determination of polychlorinated biphenyls in water

被引:140
作者
Rezaei, Faterneh [1 ,2 ]
Bidari, Araz [1 ,2 ]
Birjandi, Afsoon Pajand [1 ,2 ]
Hosseini, Mohammad Reza Milani [1 ,2 ]
Assadi, Yaghoub [1 ,2 ]
机构
[1] Iran Univ Sci & Technol, Fac Chem, Dept Analyt Chem, Tehran, Iran
[2] Iran Univ Sci & Technol, Electroanalyt Chem Res Ctr, Tehran, Iran
关键词
Dispersive liquid-liquid microextraction; Sample preparation; Polychlorinated biphenyl; Wateranalysis; Gas chromatography-electron-capture detection;
D O I
10.1016/j.jhazmat.2008.02.005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A very simple and powerful microextraction procedure, the dispersive liquid-liquid microextraction (DUME). was used for the determination of the content of 10 polychlorinated biphenyls (PCBs) in water samples. using gas chromatography coupled with electron-capture detection (GC-ECD). The appropriate amount of acetone (disperser solvent) and chlorohenzene (extraction solvent) at the microlevel volume was used for (his procedure. The conditions for the microextraction performance were investigated and optimized. The optimized method exhibited a good linearity (R-2 >0.996) over the Studied range (0.005-2 mu g L-1). illustrating a satisfactory precision level with R.S.D. values between 4.1% and 11.0%. The values of the detection limit (S/N=3) were found to be lower than 0.002 mu g L-1. Furthermore, a large enrichment factor for the analytes (up to a 540-fold) was achieved in a very short time for only a 5.00-mL water sample. The effectiveness of the method towards real samples was tested by analyzing well, river and seawater samples. The relative recoveries of the well, river and seawater samples, which had been spiked with different levels of PCBs were equal to 92.0-114.0%. 97.0-102.0% and 96.0-103.0%, respectively. The attained results demonstrated that DLLME combined with GC-ECD was a fast and inexpensive technique for the PCBs determination in water samples. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:621 / 627
页数:7
相关论文
共 30 条
[1]   Determination of organophosphorus pesticides in water samples by single drop microextraction and gas chromatography-flame photometric detector [J].
Ahmadi, F ;
Assadi, Y ;
Hosseini, SMRM ;
Rezaee, M .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1101 (1-2) :307-312
[2]   Miniaturized and automated sample pretreatment for determination of PCBs in environmental aqueous samples using an on-line microporous membrane liquid-liquid extraction-gas chromatography system [J].
Barri, T ;
Bergström, S ;
Norberg, J ;
Jönsson, JA .
ANALYTICAL CHEMISTRY, 2004, 76 (07) :1928-1934
[3]   On-site polymer-coated hollow fiber membrane microextraction and gas chromatography-mass spectrometry of polychlorinated biphenyls and polybrominated diphenyl ethers [J].
Basheer, Chanbasha ;
Vetrichelvan, Muthalagu ;
Valiyaveettil, Suresh ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1139 (02) :157-164
[4]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[5]   Monitoring of selenium. in water samples using dispersive liquid-liquid microextraction followed by iridium-modified tube graphite furnace atomic absorption spectrometry [J].
Bidari, Araz ;
Jahromi, Elham Zeini ;
Assadi, Yaghoub ;
Hosseini, Mohammad Reza Milani .
MICROCHEMICAL JOURNAL, 2007, 87 (01) :6-12
[6]  
BOURGEOIS DJ, 1994, INT J ENVIRON AN CH, V59, P15
[7]   MultiSimplex optimisation of the solid-phase microextraction-gas chromatographic-mass spectrometric determination of polycyclic aromatic hydrocarbons, polychlorinated biphenyls and phthalates from water samples [J].
Cortazar, E ;
Zuloaga, O ;
Sanz, J ;
Raposo, JC ;
Etxebarria, N ;
Fernández, LA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 978 (1-2) :165-175
[8]  
*ENV PROT AG, EPA608, P13
[9]  
Erickson M.D., 1997, ANAL CHEM PCBS
[10]   Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-diode array detection as an efficient and sensitive technique for determination of antioxidants [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Jonsson, Jan Ake .
ANALYTICA CHIMICA ACTA, 2007, 591 (01) :69-79