Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging

被引:79
作者
Le Roux, P [1 ]
Gilles, RJ [1 ]
McKinnon, GC [1 ]
Carlier, PG [1 ]
机构
[1] Gen Elect Med Syst, Buc, France
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1998年 / 8卷 / 05期
关键词
cardiac; fast imaging; fast spin-echo; outer volume suppression;
D O I
10.1002/jmri.1880080505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Among the ultrafast MRI techniques, the single-shot fast spin-echo sequence offers a robust alternative to echo planar imaging, essentially because of a much reduced sensitivity to B-o inhomogeneity. This property is particularly appealing in situations in which B, inhomogeneities can be severe and difficult to correct, such as in cardiac imaging. With single-shot cardiac imaging, however, achieving high resolution over the necessarily large field of views without introducing back-folding artifacts is problematic. One option is to use multishot sequences. However, then issues related to cardiac gating arise. Another solution is to use, optimized presaturation slabs with quadratic phase pulses generated by the Shinnar-LeRoux algorithm. These can be set to reduce the field of view in the phase-encoding direction, resulting in a reduction in the number of phase-encoding steps. For instance, for a 1 x 2-mm spatial resolution, over a rectangular, 250 x 125-mm held of view, and using a half Fourier acquisition, an echo-train length of only 40 is required. With a 4,5-msec echo spacing, the total imaging time is approximate to 180 msec, The efficacy of this solution on phantoms and volunteers is demonstrated. Multislice short-axis examinations of the whole heart, realized within a single short breath-hold of approximate to 10 seconds, are shown. The possibility of investigating not only cardiac anatomy but also both contractility and myocardial perfusion is discussed.
引用
收藏
页码:1022 / 1032
页数:11
相关论文
共 37 条
  • [1] 1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING
    ATKINSON, DJ
    BURSTEIN, D
    EDELMAN, RR
    [J]. RADIOLOGY, 1990, 174 (03) : 757 - 762
  • [2] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [3] NONINVASIVE EVALUATION OF GLOBAL LEFT-VENTRICULAR FUNCTION WITH USE OF CINE NUCLEAR MAGNETIC-RESONANCE
    BUSER, PT
    AUFFERMANN, W
    HOLT, WW
    WAGNER, S
    KIRCHER, B
    WOLFE, C
    HIGGINS, CB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) : 1294 - 1300
  • [4] REAL-TIME MOVIE IMAGING FROM A SINGLE CARDIAC CYCLE BY NMR
    CHAPMAN, B
    TURNER, R
    ORDIDGE, RJ
    DOYLE, M
    CAWLEY, M
    COXON, R
    GLOVER, P
    MANSFIELD, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (03) : 246 - 254
  • [5] MAGNETIC-RESONANCE IMAGING STRATEGIES FOR HEART STUDIES
    CROOKS, LE
    BARKER, B
    CHANG, H
    FEINBERG, D
    HOENNINGER, JC
    WATTS, JC
    MITSUAKI, A
    KAUFMAN, L
    SHELDON, PE
    BOTVINICK, E
    HIGGINS, CB
    [J]. RADIOLOGY, 1984, 153 (02) : 459 - 465
  • [6] DEBOER RW, 1994, P 2 ANN SCI M SOC MA, P1548
  • [7] SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST
    EDELMAN, RR
    WALLNER, B
    SINGER, A
    ATKINSON, DJ
    SAINI, S
    [J]. RADIOLOGY, 1990, 177 (02) : 515 - 521
  • [8] ELEVELT AJ, 1994, P 2 ANN SCI M SOC MA, P301
  • [9] Elliott DF, 1987, HDB DIGITAL SIGNAL P
  • [10] INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION
    FEINBERG, DA
    HOENNINGER, JC
    CROOKS, LE
    KAUFMAN, L
    WATTS, JC
    ARAKAWA, M
    [J]. RADIOLOGY, 1985, 156 (03) : 743 - 747