PMU-Based Detection of Voltage Imbalances with Tolerance Constraints

被引:21
作者
Routtenberg, Tirza [1 ]
Concepcion, Ricky [2 ]
Tong, Lang [3 ]
机构
[1] Ben Gurion Univ Negev, Dept Elect & Comp Engn, IL-84105 Beer Sheva, Israel
[2] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[3] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14853 USA
基金
美国国家科学基金会;
关键词
Phasor measurement unit (PMU); microgrids; off-nominal frequencies; power system monitoring; unbalanced power system; symmetrical components; state estimation; generalized locally most powerful (GLMP) test; STATE ESTIMATION; UNBALANCED VOLTAGE; POWER; FREQUENCY; PERFORMANCE; TESTS;
D O I
10.1109/TPWRD.2016.2591727
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The problem of voltage imbalance detection in a three-phase power system using phasor measurement unit (PMU) data is considered within a hypothesis testing framework. Ageneral model for the PMU output with a downsampled negative sequence is presented. The new formulation takes into account computation complexity and tolerance of imbalance. A new monitoring tool, referred to as a generalized locally most powerful (GLMP) test, is proposed for detection in the presence of nuisance parameters. A closed-form expression of the GLMP test is developed for the detection of an imbalance problem, based on a single PMU's measurements. Numerical simulations show improved performance over benchmark techniques.
引用
收藏
页码:484 / 494
页数:11
相关论文
共 52 条
[11]  
Concepcion Ricky, 2015, 2015 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT). Proceedings, P1, DOI 10.1109/ISGT.2015.7131898
[12]  
Dasgupta S., 2012, Power and Energy Society General Meeting, 2012 IEEE, P1, DOI DOI 10.1109/PESGM.2012.6345522
[13]  
Davoudi Masoud Ghiafeh, 2012, 2012 11th International Conference on Environment and Electrical Engineering, P860, DOI 10.1109/EEEIC.2012.6221496
[14]   A PLL-Based Multirate Structure for Time-Varying Power Systems Harmonic/Interharmonic Estimation [J].
de Carvalho, Janison Rodrigues ;
Duque, Carlos A. ;
Ribeiro, Moises V. ;
Cerqueira, Augusto S. ;
Baldwin, Thomas L. ;
Ribeiro, Paulo F. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) :1789-1800
[15]   Influence of unbalanced voltage on the steady-state performance of a three-phase squirrel-cage induction motor [J].
Faiz, J ;
Ebrahimpour, H ;
Pillay, P .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) :657-662
[16]   Phasor-based synchronized frequency measurement in power systems [J].
Fan, Dawei ;
Centeno, Virgilio .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) :2010-2016
[17]  
FERREIRA A., 2010, XIII SEMEAD - Seminarios em Administracao, P1, DOI DOI 10.1109/ICHQP
[18]   A Robust PMU Based Three-Phase State Estimator Using Modal Decoupling [J].
Goel, Murat ;
Abur, Ali .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (05) :2292-2299
[19]   A Multilevel State Estimation Paradigm for Smart Grids [J].
Gomez-Exposito, Antonio ;
Abur, Ali ;
de la Villa Jaen, Antonio ;
Gomez-Quiles, Catalina .
PROCEEDINGS OF THE IEEE, 2011, 99 (06) :952-976
[20]   POWER-SYSTEM STATE ESTIMATION USING 3-PHASE MODELS [J].
HANSEN, CW ;
DEBS, AS .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :818-824