Subacute stent thrombosis and the anticoagulation controversy: Changes in drug therapy, operator technique, and the impact of intravascular ultrasound

被引:64
作者
Moussa, I
DiMario, C
DiFrancesco, L
Reimers, B
Blengino, S
Colombo, A
机构
[1] CTR CUORE COLUMBUS,I-20145 MILAN,ITALY
[2] LENOX HILL HOSP,DIV CARDIOL,NEW YORK,NY 10021
关键词
D O I
10.1016/S0002-9149(96)00486-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Clinical trials have shown that stents are superior to other catheter-based coronary interventions in terms of reduced complications and improved long-term efficacy. With utilization of high-pressure balloon inflation and intravascular ultrasound (IVUS) guidance, stent implantation can now be performed safely without anticoagulation (i.e., with lower rates of stent thrombosis and vascular complications). In 2 recent prospective clinical trials, stent thrombosis occurred in 3.5% of cases despite anticoagulant therapy, which resulted in an average of 7% vascular and bleeding complications. Initial use of IVUS during traditional stent deployment showed that 80% of stents were underexpanded and led to the hypothesis that stent thrombosis might be decreased as a result of optimal stent placement under IVUS guidance without the need for anticoagulation. In a prospective clinical trial to test this hypothesis, three factors were found to reduce stent thrombosis: full stent expansion, complete apposition to the vessel wall, and full lesion coverage. Predictors of thrombotic risk in this era of high-pressure stent deployment without anticoagulation include low election fraction, residual dissections, slow flow, multiple stents per lesion, and smaller postprocedure stent luminal diameter. To optimize stent expansion, stent dilation should be performed using a mean inflation pressure of 18 atm with a noncompliant or minimally compliant balloon sized to the vessel being treated (B/V ratio = 1.1). Controversy still remains about the best poststent antiplatelet regimen, and results of a recent trial should indicate whether heparin coating provides additional protection from stent thrombosis.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 35 条
[1]   PREDICTORS OF THROMBOTIC COMPLICATIONS AFTER PLACEMENT OF THE FLEXIBLE COIL STENT [J].
AGRAWAL, SK ;
HO, DSW ;
LIU, MW ;
IYER, S ;
HEARN, JA ;
CANNON, AD ;
MACANDER, PJ ;
DEAN, LS ;
BAXLEY, WA ;
ROUBIN, GS .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (16) :1216-1219
[2]   DETERMINANTS OF CORONARY COMPLIANCE IN PATIENTS WITH CORONARY-ARTERY DISEASE - AN INTRAVASCULAR ULTRASOUND STUDY [J].
ALFONSO, F ;
MACAYA, C ;
GOICOLEA, J ;
HERNANDEZ, R ;
SEGOVIA, J ;
ZAMORANO, J ;
BANUELOS, C ;
ZARCO, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (04) :879-884
[3]   THE ROLE OF PLATELETS AND ADP IN EXPERIMENTAL THROMBOSIS INDUCED BY VENOUS STASIS IN THE RAT [J].
BERNAT, A ;
VALLEE, E ;
MAFFRAND, JP ;
GORDON, JL .
THROMBOSIS RESEARCH, 1988, 52 (01) :65-70
[4]  
BLASINI R, 1995, CIRCULATION, V92, P223
[5]  
CAPUTO R, 1995, CIRCULATION S1, V92, P545
[6]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[7]   TRANS-LUMINAL EXPANDABLE NITINOL COIL STENT GRAFTING - PRELIMINARY-REPORT [J].
DOTTER, CT ;
BUSCHMANN, RW ;
MCKINNEY, MK ;
ROSCH, J .
RADIOLOGY, 1983, 147 (01) :259-260
[8]   TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION [J].
DOTTER, CT ;
JUDKINS, MP .
CIRCULATION, 1964, 30 (05) :654-&
[9]  
DOTTER CT, 1969, INVEST RADIOL, V4, P327
[10]   INCREASED CORONARY PERFORATION IN THE NEW DEVICE ERA - INCIDENCE, CLASSIFICATION, MANAGEMENT, AND OUTCOME [J].
ELLIS, SG ;
AJLUNI, S ;
ARNOLD, AZ ;
POPMA, JJ ;
BITTL, JA ;
EIGLER, NL ;
COWLEY, MJ ;
RAYMOND, RE ;
SAFIAN, RD ;
WHITLOW, PL .
CIRCULATION, 1994, 90 (06) :2725-2730