Oxidized titanium implants in reconstructive jaw surgery

被引:18
作者
Brechter, M
Nilson, H
Lundgren, S [1 ]
机构
[1] Umea Univ, Dept Oral & Maxillofacial Surg, SE-90187 Umea, Sweden
[2] Umea Univ, Dept Prosthet Dent, SE-90187 Umea, Sweden
关键词
anodic oxidation; implants; jaw bone reconstruction; modified surface; resonance frequency analysis;
D O I
10.1111/j.1708-8208.2005.tb00079.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Rehabilitation with implant-supported bridges in patients with insufficient bone volumes may require bone reconstructive procedures in conjunction with or prior to implant placement. Clinical follow-up studies using turned titanium and bone grafts have demonstrated higher failure rates than when used in nongrafted patients. Improved bone integration has been demonstrated for oxidized titanium implants; however, their clinical performance in bone reconstruction situations is not known. Purpose: This study was performed to analyze the survival and stability of oxidized titanium implants placed in patients subjected to reconstructive jaw surgery at one clinic. Materials and Methods: Two hundred oxidized titanium implants (Mk III, TiUnite(TM), Nobel Biocare AB, Goteborg, Sweden) were placed in 47 patients in conjunction with or secondary to six different reconstructive procedures owing to insufficient bone volume. In all six groups, implant stability was assessed by resonance frequency analysis and manually checked for rotation stability at implant insertion, at the time of abutment connection, and after a minimum of 12 months of loading of the prosthetic construction. Periapical radiographs were taken after a minimum of 12 months of loading (mean 21 months) for evaluation of the marginal bone levels. The mean clinical follow-up period was 30 months. Results: Of the 200 implants, 199 were considered osseointegrated at the time of abutment surgery. At the 12-month post-loading follow-up, another two implants were considered not stable. Three implants (1.5%) were ranked as unsuccessful. Conclusion: Clinical experience with 200 consecutive oxidized implants in various reconstruction situations shows a successful outcome, with only three failures (1.5%) during a mean follow-up period of 30 months.
引用
收藏
页码:S83 / S87
页数:5
相关论文
共 27 条
[1]  
ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P233
[2]  
Albrektsson T, 2000, APPL OSSEOINTEGRATIO, V1, P21
[3]  
Becktor JP, 2004, INT J ORAL MAX IMPL, V19, P107
[4]   Mandibular alveolar ridge augmentation in the dog using distraction osteogenesis [J].
Block, MS ;
Chang, A ;
Crawford, C .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (03) :309-314
[5]  
BOYNE PJ, 1980, J ORAL SURG, V38, P613
[6]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[7]   Distraction osteogenesis in maxillofacial surgery using internal devices: Review of five cases [J].
Chin, M ;
Toth, BA .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (01) :45-53
[8]  
Clavero Jaime, 2003, Clin Implant Dent Relat Res, V5, P154, DOI 10.1111/j.1708-8208.2003.tb00197.x
[9]  
Cricchio Giovanni, 2003, Clin Implant Dent Relat Res, V5, P161, DOI 10.1111/j.1708-8208.2003.tb00198.x
[10]   Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading -: Successful vs. failing implants [J].
Glauser, R ;
Sennerby, L ;
Meredith, N ;
Rée, A ;
Lundgren, A ;
Gottlow, J ;
Hämmerle, CHF .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :428-434