Analysis of chimney height for solar chimney power plant

被引:125
作者
Zhou, Xinping [1 ]
Yang, Jiakuan [2 ]
Xiao, Bo [2 ]
Hou, Guoxiang [3 ]
Xing, Fang [2 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Civil Engn & Mech, Wuhan 430074, Hubei, Peoples R China
[2] Huazhong Univ Sci & Technol, Sch Environm Sci & Engn, Wuhan 430074, Hubei, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Traff Sci & Engn, Wuhan 430074, Hubei, Peoples R China
关键词
Solar chimney; Maximum height; Optimal height; THEORETICAL PERFORMANCE; TEMPERATURE; GENERATION; ENERGY; FIELD; MODEL;
D O I
10.1016/j.applthermaleng.2008.02.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
Current in solar chimney power plant that drives turbine generators to generate electricity is driven by buoyancy resulting from higher temperature than the surroundings at different heights. In this paper, the maximum chimney height for convection avoiding negative buoyancy at the latter chimney and the optimal chimney height for maximum power output are presented and analyzed using a theoretical model validated with the measurements of the only one prototype in Manzanares. The results based on the Manzanares prototype show that as standard lapse rate of atmospheric temperature is used, the maximum power output of 102.2 kW is obtained for the optimal chimney height of 615 m, which is lower than the maximum chimney height with a power output of 92.3 kW. Sensitivity analyses are also performed to examine the influence of various lapse rates of atmospheric temperatures and collector radii on maximum height of chimney. The results show that maximum height gradually increases with the lapse rate increasing and go to infinity at a value of around 0.0098 K m(-1), and that the maximum height for convection and optimal height for maximum power output increase with larger collector radius. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:178 / 185
页数:8
相关论文
共 31 条
[11]   Available energy of the air in solar chimneys and the possibility of its ground-level concentration [J].
Ninic, N. .
SOLAR ENERGY, 2006, 80 (07) :804-811
[12]   Performance of a solar chimney [J].
Ong, KS ;
Chow, CC .
SOLAR ENERGY, 2003, 74 (01) :1-17
[13]   The potential of solar chimney for application in rural areas of developing countries [J].
Onyango, Frederick N. ;
Ochieng, Reccab M. .
FUEL, 2006, 85 (17-18) :2561-2566
[14]  
PAPAGEORGIOU C, 2004, IASTED P POW EN SYST, P151
[15]   Numerical and analytical calculations of the temperature and flow field in the upwind power plant [J].
Pastohr, H ;
Kornadt, O ;
Gürlebeck, K .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (06) :495-510
[16]  
Pasumarthi N, 1998, INT J ENERG RES, V22, P443, DOI 10.1002/(SICI)1099-114X(199804)22:5<443::AID-ER381>3.0.CO
[17]  
2-V
[18]  
Pasumarthi N, 1998, INT J ENERG RES, V22, P277, DOI 10.1002/(SICI)1099-114X(19980310)22:3<277::AID-ER380>3.0.CO
[19]  
2-R
[20]   Critical evaluation of solar chimney power plant performance [J].
Pretorius, JP ;
Kröger, DG .
SOLAR ENERGY, 2006, 80 (05) :535-544