IMPROVING COOLING SYSTEM EFFICIENCY WITH PRE-COOLING

被引:0
|
作者
Schutte, A. J. [1 ]
Pelzer, R. [1 ]
Mathews, E. H. [1 ]
机构
[1] North West Univ, CRCED, Pretoria, South Africa
来源
2012 PROCEEDINGS OF THE 9TH INDUSTRIAL AND COMMERCIAL USE OF ENERGY CONFERENCE (ICUE) | 2012年
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Mine production water is cooled on the surface by pre-cooling towers before entering the refrigeration process. Poor water quality and broken draft fans reduce the cooling efficiency and utilisation of a pre-cooling tower. The pre-cooling towers and refrigeration plant operate at full load during the summer months to deliver the required cooling. During the winter months, the bulk air coolers are stopped and extra refrigeration capacity becomes available. For this reason maintenance on the pre-cooling tower is scheduled during the winter months. A case study was done on a mine refrigeration system where the water quality was poor. Dissolved salts form crystals on the heat exchanger's film surface when the temperature of the solution is reduced. Solid particles suspended in the water compounded the situation by further clogging the fill of the pre-cooling tower. The cooling capacity of the pre-cooling tower was greater than required and could be replaced by a lower maintenance fill. The increase in utilisation is at a cost of efficiency. Each of the eight cell's large fan was replaced by four high-speed direct drive fans with an improved efficiency and better utilisation factor. The overall system efficiency increased and resulted in an average power saving of 1.00 MW over a 24 hour day on average on the mine refrigeration system. The system maintained the same level of service to the mine production process.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The effect of pre-cooling intensity on cooling efficiency and exercise performance
    Bogerd, Nina
    Perret, Claudio
    Bogerd, Cornelis P.
    Rossi, Rene M.
    Daanen, Hein A. M.
    JOURNAL OF SPORTS SCIENCES, 2010, 28 (07) : 771 - 779
  • [2] Pre-cooling Intensity Effects on Cooling Efficiency in Cryogenic Turning
    Musavi, Seyed Hasan
    Davoodi, Behnam
    Eskandari, Behzad
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (12) : 10389 - 10396
  • [3] Pre-cooling Intensity Effects on Cooling Efficiency in Cryogenic Turning
    Seyed Hasan Musavi
    Behnam Davoodi
    Behzad Eskandari
    Arabian Journal for Science and Engineering, 2019, 44 : 10389 - 10396
  • [4] Demand response via pre-cooling and solar pre-cooling: A review
    Naderi, Shayan
    Pignatta, Gloria
    Heslop, Simon
    MacGill, Iain
    Chen, Dong
    ENERGY AND BUILDINGS, 2022, 272
  • [5] Improving deep-level mining refrigeration through increasing pre-cooling efficiency
    Terblanche, B. G. G.
    van Rensburg, J. F.
    Biermann, W.
    PROCEEDINGS OF THE 2018 16TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2018, : 95 - 99
  • [6] Studies on Pre-Cooling of Tomato
    Pandiarajan, T.
    Tajuddin, A.
    AMA-AGRICULTURAL MECHANIZATION IN ASIA AFRICA AND LATIN AMERICA, 2014, 45 (03): : 59 - 63
  • [7] Pre-Cooling for Performance in the Heat
    Roberts, W.
    XXXI FIMS SPORTS MEDICINE WORLD CONGRESS, 2010, : 29 - 32
  • [8] Studies on pre-cooling of tomato
    Pandiarajan, T., 1600, Farm Machinery Industrial Research Corp. (45):
  • [9] A Novel Temperature-Independent Model for Estimating the Cooling Energy in Residential Homes for Pre-Cooling and Solar Pre-Cooling
    Heslop, Simon
    Yildiz, Baran
    Roberts, Mike
    Chen, Dong
    Lau, Tim
    Naderi, Shayan
    Bruce, Anna
    MacGill, Iain
    Egan, Renate
    ENERGIES, 2022, 15 (23)
  • [10] Numerical investigation of pre-cooling characteristics of heat exchange pre-cooling engine and engine performance
    Luo, Jiamao
    Yang, Shunhua
    Zhang, Jianqiang
    Li, Ji
    Liu, Yu
    Zhang, Wanzhou
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2019, 40 (05):