Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

被引:17
作者
Perez-Vives, Cari [1 ]
Ferrer-Blasco, Teresa [1 ]
Dominguez-Vicent, Alberto [1 ]
Garcia-Lazaro, Santiago [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Fac Phys, Dept Opt, Opt Res Grp, E-46100 Valencia, Spain
关键词
PHAKIC INTRAOCULAR-LENS; IN-SITU KERATOMILEUSIS; ADMINISTRATION CLINICAL-TRIAL; HIGH MYOPIC ASTIGMATISM; FOLLOW-UP; CONTACT-LENS; MODERATE; ICL; DECENTRATION; HYPEROPIA;
D O I
10.1016/j.ajo.2012.09.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery. DESIGN: Prospective study in humans. METHODS: An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated. RESULTS: At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diopter (D) implantable collamer lens at 25 cycles/degree (cpd) (P < .05). At 5 mm pupil, statistically significant differences in Strehl ratio, VA, and contrast sensitivity were found between both incision sizes for all implantable collamer lens powers (P < .05). The outcomes were better with small incision. Implantable collamer lens power also affected the optical and visual quality. At 3 mm pupil, no statistically significant differences were found in VA and contrast sensitivity between implantable collamer lens powers, except between -3 and -15 D at low-contrast VA and at 2,0 and 25 cpd (P < .05). At 5 mm pupil, no statistically significant differences were found in Strehl ratio, VA, and contrast sensitivity between -3 and -6 D implantable collamer lens, but they did become apparent for -15 D implantable collamer lens for both incision sizes, all contrasts and spatial frequencies (P < .05). CONCLUSIONS: The implantable collamer lens provides good optical and visual quality, although these outcomes decreased with large-incision surgery because of the increase of aberrations. (Am J Ophthalmol 2013;155:499-507. (C) 2013 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:499 / 507
页数:9
相关论文
共 30 条
[1]   Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: Five-year follow-up [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :873-880
[2]   Collagen copolymer toric posterior chamber phakic intraocular lenses to correct high myopic astigmatism [J].
Alfonso, Jose F. ;
Baamonde, Begona ;
Madrid-Costa, David ;
Fernandes, Paulo ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) :1349-1357
[3]   Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism One-year follow-up [J].
Alfonso, Jose F. ;
Fernandez-Vega, Luis ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :568-576
[4]   MAGNIFICATION AND VISUAL-ACUITY IN REFRACTIVE SURGERY [J].
APPLEGATE, RA ;
HOWLAND, HC .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (10) :1335-1342
[5]   The Freiburg Visual Acuity test - Automatic measurement of visual acuity [J].
Bach, M .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (01) :49-53
[6]  
Davidorf JM, 1998, J REFRACT SURG, V14, P306
[7]   Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential Complications [J].
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Madrid-Costa, David ;
Ferrer-Blasco, Teresa ;
Jorge, Jorge ;
Montes-Mico, Robert .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :765-776
[8]   Adaptive optics with a magnetic deformable mirror:: applications in the human eye [J].
Fernández, Enrique J. ;
Vabre, Laurent ;
Hermann, Boris ;
Unterhuber, Angelika ;
Povazay, Boris ;
Drexler, Wolfgang .
OPTICS EXPRESS, 2006, 14 (20) :8900-8917
[9]   Implantable contact lens for moderate to high myopia - Short-term follow-up of 2 models [J].
Gonvers, M ;
Othenin-Girard, P ;
Bornet, C ;
Sickenberg, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (03) :380-388
[10]   Quality of Life in High Myopia before and after Implantable Collamer Lens Implantation [J].
Ieong, Alvin ;
Hau, Scott C. H. ;
Rubin, Gary S. ;
Allan, Bruce D. S. .
OPHTHALMOLOGY, 2010, 117 (12) :2295-2300