Building integration of solar thermal systems-example of a refurbishment of a church rectory

被引:8
作者
Cristofari, C. [1 ]
Carutasiu, M. B. [2 ]
Canaletti, J. L. [1 ]
Norvasiene, R. [3 ]
Motte, F. [1 ]
Notton, G. [1 ]
机构
[1] Univ Corsica, UMR CNRS 6134 Sci Ctr Georges Peri, Route Sanguinaires, F-20000 Ajaccio, France
[2] Univ Politehn Bucuresti, Power Engn Fac, Dept Energy Prod & Use, Bucharest, Romania
[3] Kaunas Univ Technol, Inst Architecture & Construct, Tvirtoves Al 35, LT-50155 Kaunas, Lithuania
关键词
Solar energy; Thermal collectors; Building integration; MULTIOBJECTIVE OPTIMIZATION MODEL; ECONOMIC-ENVIRONMENTAL EVALUATION; COMPREHENSIVE ANALYSIS; PHOTOVOLTAIC PANELS; COOLING TECHNIQUES; VIABILITY; COLLECTOR; EMPHASIS; DESIGN; PLANTS;
D O I
10.1016/j.renene.2018.05.026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Given the fact that the solar industry is relatively mature, and the costs of equipment are stabilized, the utilization of solar thermal equipment in reducing the energy consumption in buildings increased. For this reason, in the frame of the present work, a new flat plate solar collector (H2OSS (R)) and a new solar air collector (Volet'air (R)) with high building integration were analyzed. Moreover, in concordance with the goals of European Project "Maritimo", which implies refurbishing the Mediterranean houses, this Paper presents the energy reduction resulted from integrating these solar systems. They were used to refurbish a building placed in Bocognano, Corsica, France, near the center of the island. The performances of the patented solar equipment were simulated using the RETScreen software considering that the building has double utilization: two apartments are used for tourist accommodation (considered to be booked half a year), and two apartments serves as a church rectory (whole year utilization). Using the patented flat solar water collector, the annual energy requirement for hot water preparation decreased with 45%, from 2845 kWh to 1292 kWh, when analyzing the church rectory. Considering the same hot water consumption profile but using the vacuum solar collector, the total heat delivered increased to 1615 kWh, even if the total collector's area decreased from 2.02 m(2) to 1.80 m(2). The same vacuum system provided a 69% solar fraction (energy reduction from 1392 kWh/year to 960 kWh/year) for the accommodation apartments. The air heaters were mounded as windows shutters and have different areas for each orientation, thus different thermal energy production. Consequently, they were analyzed separately, and the heat delivered ranged from 646 kWh/year (East orientation) to 3479 kWh/year (South orientation). The total thermal energy provided by the solar air shutters was 5567 kWh/year, meaning approximatively 47% of the total energy required to maintain the interior temperature at 21 degrees C. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:67 / 81
页数:15
相关论文
共 35 条
[11]   Environmental impact assessments of hybrid photovoltaic-thermal (PV/T) systems - A review [J].
Good, Clara .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 55 :234-239
[12]   Design, construction and performance prediction of integrated solar roof collectors using finite element analysis [J].
Hassan, Marwa A. ;
Beliveau, Yvan .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (05) :1069-1078
[13]   An integrated multi-objective optimization model for determining the optimal solution in the solar thermal energy system [J].
Kim, Jimin ;
Hong, Taehoon ;
Jeong, Jaemin ;
Lee, Myeonghwi ;
Koo, Choongwan ;
Lee, Minhyun ;
Ji, Changyoon ;
Jeong, Jaewook .
ENERGY, 2016, 102 :416-426
[14]   An integrated multi-objective optimization model for determining the optimal solution in implementing the rooftop photovoltaic system [J].
Koo, Choongwan ;
Hong, Taehoon ;
Lee, Minhyun ;
Kim, Jimin .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 :822-837
[15]   Photovoltaic/thermal (PVT) systems: A review with emphasis on environmental issues [J].
Lamnatou, Chr. ;
Chemisana, D. .
RENEWABLE ENERGY, 2017, 105 :270-287
[16]   Building-integrated solar thermal systems based on vacuum-tube technology: Critical factors focusing on life-cycle environmental profile [J].
Lamnatou, Chr. ;
Cristofari, C. ;
Chemisana, D. ;
Canaletti, J. L. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 65 :1199-1215
[17]   Review and perspectives on Life Cycle Analysis of solar technologies with emphasis on building-integrated solar thermal systems [J].
Lamnatou, Chr ;
Chemisana, D. ;
Mateus, R. ;
Almeida, M. G. ;
Silva, S. M. .
RENEWABLE ENERGY, 2015, 75 :833-846
[18]   Preliminary determination of optimal size for renewable energy resources in buildings using RETScreen [J].
Lee, Kyoung-Ho ;
Lee, Dong-Won ;
Baek, Nam-Choon ;
Kwon, Hyeok-Min ;
Lee, Chang-Jun .
ENERGY, 2012, 47 (01) :83-96
[19]  
LENG GREGORY J., 2004, RETScreen International: results and impacts 1996 - 2012
[20]   Techno-economic comparative analysis of off-grid hybrid photovoltaic/diesel/battery and photovoltaic/battery power systems for a household in Urumqi, China [J].
Li, Chong ;
Yu, Weiyan .
JOURNAL OF CLEANER PRODUCTION, 2016, 124 :258-265