Real-time 2D/3D registration for tumor motion tracking during radiotherapy

被引:0
作者
Furtado, H. [1 ]
Gendrin, C. [1 ]
Bloch, C. [1 ]
Spoerk, J. [1 ]
Pawiro, S. A. [1 ]
Weber, C. [1 ]
Figl, M. [1 ]
Stock, M. [2 ]
Georg, D. [2 ]
Bergmann, H. [1 ]
Birkfellner, W. [1 ]
机构
[1] Med Univ Vienna, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Med Univ Vienna, Univ Clin Radiotherapy, Div Med Phys, Vienna, Austria
来源
MEDICAL IMAGING 2012: IMAGE PROCESSING | 2012年 / 8314卷
基金
奥地利科学基金会;
关键词
Image guided radiation therapy; 2D/3D registration; general purpose computations on graphics hardware; CUDA; VALIDATION; PROSTATE; LUNG;
D O I
10.1117/12.910117
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Organ motion during radiotherapy is one of causes of uncertainty in dose delivery. To cope with this, the planned target volume (PTV) has to be larger than needed to guarantee full tumor irradiation. Existing methods deal with the problem by performing tumor tracking using implanted fiducial markers or magnetic sensors. In this work, we investigate the feasibility of using x-ray based real time 2D/3D registration for non-invasive tumor motion tracking during radiotherapy. Our method uses purely intensity based techniques, thus avoiding markers or fiducials. X-rays are acquired during treatment at a rate of 5.4Hz. We iteratively compare each x-ray with a set of digitally reconstructed radiographs (DRR) generated from the planning volume dataset, finding the optimal match between the x-ray and one of the DRRs. The DRRs are generated using a ray-casting algorithm, implemented using general purpose computation on graphics hardware (GPGPU) programming techniques using CUDA for greater performance. Validation is conducted off-line using a phantom and five clinical patient data sets. The registration is performed on a region of interest (ROI) centered around the PTV. The phantom motion is measured with an rms error of 2.1 mm and mean registration time is 220 ms. For the patient data sets, a sinusoidal movement that clearly correlates to the breathing cycle is seen. Mean registration time is always under 105 ms which is well suited for our purposes. These results demonstrate that real-time organ motion monitoring using image based markerless registration is feasible.
引用
收藏
页数:8
相关论文
共 21 条
[1]   QUANTIFYING INTERFRACTION AND INTRAFRACTION TUMOR MOTION IN LUNG STEREOTACTIC BODY RADIOTHERAPY USING RESPIRATION-CORRELATED CONE BEAM COMPUTED TOMOGRAPHY [J].
Bissonnette, Jean-Pierre ;
Franks, Kevin N. ;
Purdie, Thomas G. ;
Moseley, Douglas J. ;
Sonke, Jan-Jakob ;
Jaffray, David A. ;
Dawson, Laura A. ;
Bezjak, Andrea .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03) :688-695
[2]   4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis [J].
Boldea, Vlad ;
Sharp, Gregory C. ;
Jiang, Steve B. ;
Sarrut, David .
MEDICAL PHYSICS, 2008, 35 (03) :1008-1018
[3]   A monoscopic method for real-time tumour tracking using combined occasional x-ray imaging and continuous respiratory monitoring [J].
Cho, Byungchul ;
Suh, Yelin ;
Dieterich, Sonja ;
Keall, Paul J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2837-2855
[4]   REAL-TIME TARGET POSITION ESTIMATION USING STEREOSCOPIC KILOVOLTAGE/MEGAVOLTAGE IMAGING AND EXTERNAL RESPIRATORY MONITORING FOR DYNAMIC MULTILEAF COLLIMATOR TRACKING [J].
Cho, Byungchul ;
Poulsen, Per Rugaard ;
Sawant, Amit ;
Ruan, Dan ;
Keall, Paul J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (01) :269-278
[5]  
Gendrin C., 2011, RADIOTHERAPY ONCOLOG
[6]   Validation for 2D/3D registration II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set [J].
Gendrin, Christelle ;
Markelj, Primoz ;
Pawiro, Supriyanto Ardjo ;
Spoerk, Jakob ;
Bloch, Christoph ;
Weber, Christoph ;
Figl, Michael ;
Bergmann, Helmar ;
Birkfellner, Wolfgang ;
Likar, Bostjan ;
Pernus, Franjo .
MEDICAL PHYSICS, 2011, 38 (03) :1491-1502
[7]   Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancer [J].
Hughes, Simon ;
McClelland, James ;
Tarte, Segolene ;
Lawrence, David ;
Ahmad, Shahreen ;
Hawkes, David ;
Landau, David .
RADIOTHERAPY AND ONCOLOGY, 2009, 91 (03) :336-341
[8]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[9]   Validation for 2D/3D registration I: A new gold standard data set [J].
Pawiro, S. A. ;
Markelj, P. ;
Pernus, F. ;
Gendrin, C. ;
Figl, M. ;
Weber, C. ;
Kainberger, F. ;
Noebauer-Huhmann, I. ;
Bergmeister, H. ;
Stock, M. ;
Georg, D. ;
Bergmann, H. ;
Birkfellner, W. .
MEDICAL PHYSICS, 2011, 38 (03) :1481-1490
[10]  
Powell MJD, 2006, NONCON OPTIM ITS APP, V83, P255