Differential Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones

被引:174
作者
Nakajima, Hideko Heidi [1 ,2 ]
Dong, Wei [5 ]
Olson, Elizabeth S. [5 ]
Merchant, Saumil N. [1 ,2 ,4 ]
Ravicz, Michael E. [1 ,2 ,3 ]
Rosowski, John J. [1 ,2 ,3 ,4 ]
机构
[1] Massachusetts Eye & Ear Infirm, Eaton Peabody Lab, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Dept Otol & Laryngol, Boston, MA 02115 USA
[3] MIT, Elect Res Lab, Cambridge, MA 02139 USA
[4] Harvard Mit Div Hlth Sci & Technol, Speech & Hearing Biosci & Technol Program, Cambridge, MA 02139 USA
[5] Columbia Univ, Dept Otolaryngol Head & Neck Surg, New York, NY 10032 USA
来源
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY | 2009年 / 10卷 / 01期
关键词
middle ear; cochlea; cochlear impedance; scala vestibuli; scala tympani; stapes velocity; HUMAN MIDDLE-EAR; INPUT IMPEDANCE; ROUND WINDOWS; STAPES; MOTION; TRANSMISSION; CONDUCTION; COCHLEA; OVAL; AIR;
D O I
10.1007/s10162-008-0150-y
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We present the first simultaneous sound pressure measurements in scala vestibuli and scala tympani of the cochlea in human cadaveric temporal bones. The technique we employ, which exploits microscale fiberoptic pressure sensors, enables the study of differential sound pressure at the cochlear base. This differential pressure is the input to the cochlear partition, driving cochlear waves and auditory transduction. In our results, the sound pressure in scala vestibuli (PSV) was much greater than scala tympani pressure (PST), except for very low and high frequencies where PST significantly affected the input to the cochlea. The differential pressure (PSV-PST) is a superior measure of ossicular transduction of sound compared to PSV alone: (PSV-PST) was reduced by 30 to 50 dB when the ossicular chain was disarticulated, whereas PSV was not reduced as much. The middle ear gain PSV/PEC and the differential pressure normalized to ear canal pressure ( PSV-PST)/PEC were generally bandpass in frequency dependence. At frequencies above 1 kHz, the group delay in the middle ear gain is about 83 mu s, over twice that of the gerbil. Concurrent measurements of stapes velocity produced estimates of cochlear input impedance, the differential impedance across the partition, and round window impedance. The differential impedance was generally resistive, while the round window impedance was consistent with compliance in conjunction with distributed inertia and damping. Our technique of measuring differential pressure can be used to study inner ear conductive pathologies (e. g., semicircular dehiscence), as well as non-ossicular cochlear stimulation (e. g., round window stimulation and bone conduction)-situations that cannot be completely quantified by measurements of stapes velocity or scala vestibuli pressure by themselves.
引用
收藏
页码:23 / 36
页数:14
相关论文
共 36 条
[1]   Human middle-ear sound transfer function and cochlear input impedance [J].
Aibara, R ;
Welsh, JT ;
Puria, S ;
Goode, RL .
HEARING RESEARCH, 2001, 152 (1-2) :100-109
[2]  
[Anonymous], 1960, Experiments in Hearing
[3]  
Beranek L., 1954, ACOUSTICS
[4]   The effect of methodological differences in the measurement of stapes motion in live and cadaver ears [J].
Chien, Wade ;
Ravicz, Michael E. ;
Merchant, Saumil N. ;
Rosowski, John J. .
AUDIOLOGY AND NEURO-OTOLOGY, 2006, 11 (03) :183-197
[5]   Treatment of mixed hearing losses via implantation of a vibratory transducer on the round window [J].
Colletti, Vittorio ;
Soli, Sigfrid D. ;
Carner, Marco ;
Colletti, L. .
INTERNATIONAL JOURNAL OF AUDIOLOGY, 2006, 45 (10) :600-608
[6]   INTRA-COCHLEAR SOUND PRESSURE MEASUREMENTS IN GUINEA-PIGS [J].
DANCER, A ;
FRANKE, R .
HEARING RESEARCH, 1980, 2 (3-4) :191-205
[7]  
Decraemer WF, 2004, PROCEEDINGS OF THE 3RD SYMPOSIUM ON MIDDLE EAR MECHANICS IN RESEARCH AND OTOLOGY, P3
[8]   Middle ear forward and reverse transmission in gerbil [J].
Dong, W ;
Olson, ES .
JOURNAL OF NEUROPHYSIOLOGY, 2006, 95 (05) :2951-2961
[9]  
DORF RC, 1993, ELECT ENG HDB, P1219
[10]  
GEISLER CD, 1975, ACUSTICA, V33, P220