Design and characterization of a lactate biosensor based on immobilized lactate oxidase onto gold surfaces

被引:115
作者
Parra, A
Casero, E
Vázquez, L
Pariente, F
Lorenzo, E
机构
[1] Univ Autonoma Madrid, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
[2] CSIC, Inst Ciencia Mat, E-28049 Madrid, Spain
关键词
lactase oxidase biosensor; hydroxymethylferrocene; AFM; QCM;
D O I
10.1016/j.aca.2005.09.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design and characterization of a lactate biosensor and its application to the determination of this analyte in wine and beer are described. The biosensor is developed through the immobilization of lactate oxidase (LOx) using two different strategies including direct adsorption and covalent binding. The characterization of the resulting lactate oxidase monolayers was performed in aqueous phosphate buffer solutions using atomic force microscopy (AFM) and quartz crystal microbalance (QCM) techniques. In presence of lactate and using hydroxymethylferrocene as a redox mediator, biosensors obtained by either direct adsorption or by covalent binding exhibit a clear electrocatalytic activity, and lactate could be determined amperometrically at 300 mV versus SSCE. Results obtained under these conditions give a linear current response versus lactate concentration up to 0.3 mM, with a detection limit of 10 mu M of lactate and a sensitivity of 0.77 +/- 0.08 mu A mM(-1). Finally, biosensors were applied to the determination of lactate in wine and beer. The results obtained are in good agreement with those obtained by a well-established enzymatic-spectrophotometric assay kit. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:308 / 315
页数:8
相关论文
共 30 条
[1]   Amperometric enzyme electrode for L(+)-lactate determination using immobilized L(+)-lactate oxidase in poly(vinylferrocenium) film [J].
Aydin, G ;
Çelebi, SS ;
Özyörük, H ;
Yildiz, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) :8-12
[2]   Enzymatic electrode for the determination of L-lactate [J].
Boujtita, M ;
Chapleau, M ;
ElMurr, N .
ELECTROANALYSIS, 1996, 8 (05) :485-488
[3]   Immobilization of metallothionein on gold/mica surfaces:: Relationship between surface morphology and protein-substrate interaction [J].
Casero, E ;
Vázquez, L ;
Martín-Benito, J ;
Morcillo, MA ;
Lorenzo, E ;
Pariente, M .
LANGMUIR, 2002, 18 (15) :5909-5920
[4]  
EGGINS BR, 1996, BIOSENSORS INTRO, V87, P147
[5]   Prussian Blue- and lactate oxidase-based amperometric biosensor for lactic acid [J].
Garjonyte, R ;
Yigzaw, Y ;
Meskys, R ;
Malinauskas, A ;
Gorton, L .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 79 (01) :33-38
[6]   Reagentless amperometric detection of L-lactate on an enzyme-modified conducting copolymer poly(5-hydroxy-1,4-naphthoquinone-co-5-hydroxy-3-thioacetic acid-1,4-naphthoquinone) [J].
Haccoun, J ;
Piro, B ;
Tran, LD ;
Dang, LA ;
Pham, MC .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1325-1329
[7]   Spatially resolved force spectroscopy of biological surfaces using the atomic force microscope [J].
Heinz, WF ;
Hoh, JH .
TRENDS IN BIOTECHNOLOGY, 1999, 17 (04) :143-150
[8]   Determination of L-lactic acid in yoghurt by a bienzyme amperometric graphite-Teflon composite biosensor [J].
Herrero, AM ;
Requena, T ;
Reviejo, AJ ;
Pingarrón, JM .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2004, 219 (05) :556-559
[9]  
Iwuoha EI, 1999, ELECTROANAL, V11, P367, DOI 10.1002/(SICI)1521-4109(199905)11:5<367::AID-ELAN367>3.3.CO
[10]  
2-S