Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor

被引:53
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Meyer, Mathias [1 ]
Fink, Christian [3 ]
Hohenberger, Peter [4 ]
Leidecker, Christianne [5 ]
Schoenberg, Stefan O. [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Gen Hosp Celle, Dept Radiol, Celle, Germany
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Surg,Div Surg Oncol & Thorac Surg, D-68167 Mannheim, Germany
[5] Siemens Healthcare Sect, Forchheim, Germany
关键词
Dual-source CT; dual-energy CT; gastrointestinal stromal tumor; hepatic metastasis; virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; CRITERIA; FUSION; RECIST; CHOI;
D O I
10.1016/j.acra.2014.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare in dual-energy CT (DECT) conventionally reconstructed polyenergetic images (PEI) at 120 kVp to virtual monoenergetic images (MEI) at different kiloelectron volt (key) levels for evaluation of liver and gastrointestinal stromal tumor (GIST) hepatic metastases with regard to objective (IQob) and subjective image quality (IQsub) assessed by two readers of varying experience. Image quality was correlated to patient size and compared between PEI and MEI. Materials and Methods: From 50 examinations of 17 GIST patients (12 with hepatic metastases) undergoing abdominal dual-source DECT for staging, therapy monitoring or follow-up, PEI and nine MEI in 10-keV intervals from 40 to 120 keV were reconstructed. Liver contrast-to-noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI reconstructions with the highest IQob were compared to PEI for IQsub by one experienced reader (ER) and one inexperienced reader (IR). Patients' diameters were correlated to IQob and IQsub ratings. Results: MEI at 70 keV had the highest IQob with equal liver CNR and metastasis-to-liver ratio compared to PEI. The ER rated 70-keV MEI and PEI equally high (median 4), whereas the IR rated IQsub best in 70-keV MEI (median 5). Unlike in PEI, IQsub ratings in 70-keV MEI were not correlated to patient size. Conclusions: MEI at 70 keV provided an IQob equivalent to PEI. Regarding the IR, IQsub was improved in 70-keV MEI compared to PEI and less dependent on patient size. Therefore, IRs might improve their diagnostic confidence in the assessment of hepatic GIST metastases by evaluating MEI reconstructions at 70 keV.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 50 条
  • [31] Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study
    Abdellatif, Waleed
    Esslinger, Eric
    Kobes, Kevin
    Wong, Amanda
    Powell, Jennifer
    Ali, Ismail Tawakol
    Andrews, Gordon
    Nicolaou, Savvas
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2712 - 2721
  • [32] Dual-Source Dual-Energy CT Portal Venous Phase Abdominal CT Scans in Large Body Habitus Patients: Preliminary Observations on Image Quality and Material Decomposition
    Baliyan, Vinit
    Kordbacheh, Hamed
    Serrao, Jessica
    Sahani, Dushyant V.
    Kambadakone, Avinash R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 932 - 936
  • [33] Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study
    Mangold, Stefanie
    Cannao, Paola M.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Canstein, Christian
    Fuller, Stephen R.
    Muscogiuri, Giuseppe
    Varga-Szemes, Akos
    Nikolaou, Konstantin
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1871 - 1878
  • [34] Head and neck single- and dual-energy CT: differences in radiation dose and image quality of 2nd and 3rd generation dual-source CT
    Lenga, Lukas
    Lange, Marvin
    Martin, Simon S.
    Albrecht, Moritz H.
    Booz, Christian
    Yel, Ibrahim
    Arendt, Christophe T.
    Vogl, Thomas J.
    Leithner, Doris
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1122):
  • [35] Dual-energy CT with virtual monoenergetic images and iodine maps improves tumor conspicuity in patients with pancreatic ductal adenocarcinoma
    Liang, Hongwei
    Zhou, Yang
    Zheng, Qiao
    Yan, Gaowu
    Liao, Hongfan
    Du, Silin
    Zhang, Xiaohui
    Lv, Fajin
    Zhang, Zhiwei
    Li, Yong-mei
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [36] Impact of an advanced image-based monoenergetic reconstruction algorithm on coronary stent visualization using third generation dual-source dual-energy CT: a phantom study
    Stefanie Mangold
    Paola M. Cannaó
    U. Joseph Schoepf
    Julian L. Wichmann
    Christian Canstein
    Stephen R. Fuller
    Giuseppe Muscogiuri
    Akos Varga-Szemes
    Konstantin Nikolaou
    Carlo N. De Cecco
    European Radiology, 2016, 26 : 1871 - 1878
  • [37] A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions
    De Cecco, Carlo N.
    Caruso, Damiano
    Schoepf, U. Joseph
    De Santis, Domenico
    Muscogiuri, Giuseppe
    Albrecht, Moritz H.
    Meinel, Felix G.
    Wichmann, Julian L.
    Burchett, Philip F.
    Varga-Szemes, Akos
    Sheafor, Douglas H.
    Hardie, Andrew D.
    EUROPEAN RADIOLOGY, 2018, 28 (08) : 3393 - 3404
  • [38] Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study
    G. Jay Hanson
    Gregory J. Michalak
    Robert Childs
    Brian McCollough
    Anil N. Kurup
    David M. Hough
    Judson M. Frye
    Jeff L. Fidler
    Sudhakar K. Venkatesh
    Shuai Leng
    Lifeng Yu
    Ahmed F. Halaweish
    W. Scott Harmsen
    Cynthia H. McCollough
    J. G. Fletcher
    Abdominal Radiology, 2018, 43 : 1404 - 1412
  • [39] Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT
    Wichmann, Julian L.
    Hardie, Andrew D.
    Schoepf, U. Joseph
    Felmly, Lloyd M.
    Perry, Jonathan D.
    Varga-Szemes, Akos
    Mangold, Stefanie
    Caruso, Damiano
    Canstein, Christian
    Vogl, Thomas J.
    De Cecco, Carlo N.
    EUROPEAN RADIOLOGY, 2017, 27 (02) : 642 - 650
  • [40] Impact of noise-optimized virtual monoenergetic dual-energy computed tomography on image quality in patients with renal cell carcinoma
    Martin, Simon S.
    Wichmann, Julian L.
    Pfeifer, Sophia
    Leithner, Doris
    Lenga, Lukas
    Reynolds, Michael A.
    D'Angelo, Tommaso
    Hammerstingl, Renate
    Gruber-Rouh, Tatjana
    Vogl, Thomas J.
    Albrecht, Moritz H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 97 : 1 - 7