Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor

被引:53
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Meyer, Mathias [1 ]
Fink, Christian [3 ]
Hohenberger, Peter [4 ]
Leidecker, Christianne [5 ]
Schoenberg, Stefan O. [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, Med Fac Mannheim, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
[3] Gen Hosp Celle, Dept Radiol, Celle, Germany
[4] Heidelberg Univ, Univ Med Ctr Mannheim, Med Fac Mannheim, Dept Surg,Div Surg Oncol & Thorac Surg, D-68167 Mannheim, Germany
[5] Siemens Healthcare Sect, Forchheim, Germany
关键词
Dual-source CT; dual-energy CT; gastrointestinal stromal tumor; hepatic metastasis; virtual monoenergetic imaging; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; DIAGNOSIS; CRITERIA; FUSION; RECIST; CHOI;
D O I
10.1016/j.acra.2014.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To compare in dual-energy CT (DECT) conventionally reconstructed polyenergetic images (PEI) at 120 kVp to virtual monoenergetic images (MEI) at different kiloelectron volt (key) levels for evaluation of liver and gastrointestinal stromal tumor (GIST) hepatic metastases with regard to objective (IQob) and subjective image quality (IQsub) assessed by two readers of varying experience. Image quality was correlated to patient size and compared between PEI and MEI. Materials and Methods: From 50 examinations of 17 GIST patients (12 with hepatic metastases) undergoing abdominal dual-source DECT for staging, therapy monitoring or follow-up, PEI and nine MEI in 10-keV intervals from 40 to 120 keV were reconstructed. Liver contrast-to-noise ratios (CNR) and metastasis-to-liver ratios were calculated. MEI reconstructions with the highest IQob were compared to PEI for IQsub by one experienced reader (ER) and one inexperienced reader (IR). Patients' diameters were correlated to IQob and IQsub ratings. Results: MEI at 70 keV had the highest IQob with equal liver CNR and metastasis-to-liver ratio compared to PEI. The ER rated 70-keV MEI and PEI equally high (median 4), whereas the IR rated IQsub best in 70-keV MEI (median 5). Unlike in PEI, IQsub ratings in 70-keV MEI were not correlated to patient size. Conclusions: MEI at 70 keV provided an IQob equivalent to PEI. Regarding the IR, IQsub was improved in 70-keV MEI compared to PEI and less dependent on patient size. Therefore, IRs might improve their diagnostic confidence in the assessment of hepatic GIST metastases by evaluating MEI reconstructions at 70 keV.
引用
收藏
页码:514 / 522
页数:9
相关论文
共 50 条
  • [21] Comparison of noise-optimized linearly blended images and noise-optimized virtual monoenergetic images evaluated by dual-source, dual-energy CT in cardiac vein assessment
    Kim, Gyeong Min
    Choo, Ki Seok
    Kim, Jin Hyeok
    Hwang, Jae-Yeon
    Park, Chan Kyu
    Lee, Ji Won
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2021, 62 (05) : 594 - 602
  • [22] Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography-A Prospective Study
    Ethiraju, Vijayakumaran
    Varatharajaperumal, Rajeshkumar
    Arunachalam, Venkatesh Kasi
    KuruVambath, Abdulla
    Punniyakotti, Rajesh Shanmugam
    Rajasekaran, Sriman
    Mehta, Pankaj
    Cherian, Mathew
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024,
  • [23] Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods
    Ueguchi, Takashi
    Ogihara, Ryota
    Yamada, Sachiko
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1632 - 1639
  • [24] Impact of deep learning reconstructions on image quality and liver lesion detectability in dual-energy CT: An anthropomorphic phantom study
    Pauthe, Aurelie
    Milliner, Milan
    Pasquier, Hugo
    Campagnolo, Lucie
    Mule, Sebastien
    Luciani, Alain
    MEDICAL PHYSICS, 2025,
  • [25] Impact of the automatic tube current modulation (ATCM) system on virtual monoenergetic image quality for dual-source CT: A phantom study
    Dabli, D.
    Durand, Quentin
    Frandon, J.
    de Oliveira, Fabien
    Pastor, Maxime
    Beregi, J. P.
    Greffier, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 109
  • [26] Low kV versus dual-energy virtual monoenergetic CT imaging for proven liver lesions: what are the advantages and trade-offs in conspicuity and image quality? A pilot study
    Hanson, G. Jay
    Michalak, Gregory J.
    Childs, Robert
    McCollough, Brian
    Kurup, Anil N.
    Hough, David M.
    Frye, Judson M.
    Fidler, Jeff L.
    Venkatesh, Sudhakar K.
    Leng, Shuai
    Yu, Lifeng
    Halaweish, Ahmed F.
    Harmsen, W. Scott
    McCollough, Cynthia H.
    Fletcher, J. G.
    ABDOMINAL RADIOLOGY, 2018, 43 (06) : 1404 - 1412
  • [27] Low-keV virtual monoenergetic imaging reconstructions of excretory phase spectral dual-energy CT in patients with urothelial carcinoma: A feasibility study
    Zopfs, David
    Laukamp, Kai Roman
    dos Santos, Daniel Pinto
    Sokolowski, Marcel
    Hokamp, Nils Grosse
    Maintz, David
    Borggrefe, Jan
    Persigehl, Thorsten
    Lennartz, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 135 - 143
  • [28] Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT
    Lee, Jeong Sub
    Choi, Guk Myung
    Kim, Bong Soo
    Ko, Su Yeon
    Lee, Kyung Ryeol
    Kim, Jeong Jae
    Kim, Doo Ri
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (01): : 170 - 184
  • [29] Dual-energy CT in patients with colorectal cancer: Improved assessment of hypoattenuating liver metastases using noise-optimized virtual monoenergetic imaging
    Lenga, Lukas
    Czwikla, Rouben
    Wichmann, Julian L.
    Leithner, Doris
    Albrecht, Moritz H.
    Booz, Christian
    Arendt, Christophe T.
    Yel, Ibrahim
    D'Angelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 184 - 191
  • [30] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +