Influence of relative humidity on analyzing electric field exposure using ELF electric field measurements

被引:7
作者
Korpinen, Leena H. [1 ]
Kuisti, Harri A. [2 ]
Tarao, Hiroo [1 ,3 ]
Elovaara, Jarmo A. [2 ]
机构
[1] Tampere Univ Technol, FIN-33101 Tampere, Finland
[2] Fingrid, Helsinki, Finland
[3] Kagawa Natl Coll Technol, Dept Elect & Comp Engn, Takamatsu, Kagawa, Japan
关键词
humidity; electric fields; exposure; measurements; OCCUPATIONAL-EXPOSURE; MAGNETIC-FIELDS; CURRENTS;
D O I
10.1002/bem.21776
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The objective of the study was to investigate the influence of humidity on analyzing electric field exposure using extremely low frequency (ELF) electric field measurements. The study included 322 measurements in a climate room. We used two commercial three-axis meters, EFA-3 and EFA-300, and employed two measurement techniques in the climate room where we varied the temperature from 15 to 25 degrees C, the relative humidity from 55% to 95%, and the electric field from 1 to 25kV/m. We calculated Pearson correlations between humidity and percentage errors for all data and for data at different levels of humidity. When the relative humidity was below 70%, the results obtained by the different measurement methods in terms of percentage errors were of the same order of magnitude for the considered temperatures and field strength, but the results were less reliable when the relative humidity was higher than 80%. In the future, it is important to take humidity into account when electric field measurement results will be compared to the values given in different exposure guidelines. Bioelectromagnetics 34:414-418, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:414 / 418
页数:5
相关论文
共 10 条
[1]  
Ahlbom A, 1998, HEALTH PHYS, V74, P494
[2]  
[Anonymous], 2012, TERMODINAMICA
[3]  
[Anonymous], 2002, C9562002 IEEE
[4]  
CIGRE (International Council on Large Electric Systems), 2009, C4203 CIGRE WORK GRO, P203
[5]  
ISO, 2003, 103051 ISOTR
[6]   Cardiac Pacemakers in Electric and Magnetic Fields of 400-kV Power Lines [J].
Korpinen, Leena ;
Kuisti, Harri ;
Elovaara, Jarmo ;
Virtanen, Vesa .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (04) :422-430
[7]   Occupational Exposure to Electric and Magnetic Fields While Working at Switching and Transforming Stations of 110 kV [J].
Korpinen, Leena ;
Kuisti, Harri ;
Paakkonen, Rauno ;
Vanhala, Pauli ;
Elovaara, Jarmo .
ANNALS OF OCCUPATIONAL HYGIENE, 2011, 55 (05) :526-536
[8]   Occupational exposure to electric fields and currents associated with 110 kv substation tasks [J].
Korpinen, Leena H. ;
Kuisti, Harri A. ;
Tarao, Hiroo ;
Elovaara, Jarmo A. .
BIOELECTROMAGNETICS, 2012, 33 (05) :438-442
[9]   Occupational Exposure to Electric Fields and Induced Currents Associated With 400 kV Substation Tasks From Different Service Platforms [J].
Korpinen, Leena H. ;
Elovaara, Jarmo A. ;
Kuisti, Harri A. .
BIOELECTROMAGNETICS, 2011, 32 (01) :79-83
[10]   Evaluation of Current Densities and Total Contact Currents in Occupational Exposure at 400 kV Substations and Power Lines [J].
Korpinen, Leena H. ;
Elovaara, Jarmo A. ;
Kuisti, Harri A. .