Temperature considerations during irreversible electroporation

被引:96
作者
Davalos, Rafael V. [1 ]
Rubinsky, Boris [2 ,3 ,4 ]
机构
[1] Wake Forest Univ, Virginia Tech, Sch Biomed Engn & Sci, Blacksburg, VA 24061 USA
[2] Univ Calif Berkeley, Dept Mech Engn, Dept Bioengn, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Grad Program Biophys, Berkeley, CA 94720 USA
[4] Hebrew Univ Jerusalem, Sch Comp Sci & Engn, Serv Humanity & Soc, Ctr Bioengn, IL-91904 Jerusalem, Israel
基金
中国国家自然科学基金;
关键词
Cell membrane; Irreversible electroporation; Tissue ablation; Oncology;
D O I
10.1016/j.ijheatmasstransfer.2008.04.046
中图分类号
O414.1 [热力学];
学科分类号
摘要
Certain electrical fields, when applied across a cell membrane, can have the sole effect of membrane permeabilization, which is referred to as electroporation. When the permeabilization is irreversible, the effect leads to cell death, primarily due to loss of cell homeostasis, in a process known as irreversible electroporation (IRE). This is an unusual mode of cell death that is not yet fully understood. However, it is unique among tissue ablation techniques in affecting only the cell membrane while tissue molecules, everything encompassing collagen structures to proteins, remain intact. This facilitates a possible immune response and avoids scar tissue formation. Irreversible electroporation is, therefore, substantially different from any other tissue ablation technique and has many advantages over either heating or freezing thermal ablation. However, since IRE employs electrical fields, it can produce thermal effects which could cause thermal damage if parameters are not chosen correctly, therapy negating the advantages of IRE. This study evaluates the temperature distribution during typical IRE protocols as a means to establish the electrical parameters that produce IRE alone, without thermal effects. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5617 / 5622
页数:6
相关论文
共 44 条
  • [1] A study of the immunological response to tumor ablation with irreversible Electroporation
    Al-Sakere, B.
    Bernat, C.
    Andr, F.
    Connault, E.
    Opolon, P.
    Davalos, R. V.
    Mir, L. M.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (04) : 301 - 305
  • [2] Tumor Ablation with Irreversible Electroporation
    Al-Sakere, Bassim
    Andre, Franck
    Bernat, Claire
    Connault, Elisabeth
    Opolon, Paule
    Davalos, Rafael V.
    Rubinsky, Boris
    Mir, Lluis M.
    [J]. PLOS ONE, 2007, 2 (11):
  • [3] Thermal damage reduction associated with in vivo skin electroporation:: A numerical investigation justifying aggressive pre-cooling
    Becker, S. M.
    Kuznetsov, A. V.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (1-2) : 105 - 116
  • [4] Numerical modeling of in vivo plate electroporation thermal dose assessment
    Becker, SM
    Kuznetsov, AV
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 76 - 84
  • [5] Chang D.C., 1992, GUIDE ELECTROPORATIO
  • [6] Theoretical analysis of the thermal effects during in vivo tissue electroporation
    Davalos, RV
    Rubinsky, B
    Lir, LM
    [J]. BIOELECTROCHEMISTRY, 2003, 61 (1-2) : 99 - 107
  • [7] Tissue ablation with irreversible electroporation
    Davalos, RV
    Mir, LM
    Rubinsky, B
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (02) : 223 - 231
  • [8] Electrical impedance tomography for imaging tissue electroporation
    Davalos, RV
    Otten, DM
    Mir, LM
    Rubinsky, B
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2004, 51 (05) : 761 - 767
  • [9] A feasibility study for electrical impedance tomography as a means to monitor tissue electroporation for molecular medicine
    Davalos, RV
    Rubinsky, B
    Otten, DM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (04) : 400 - 403
  • [10] Blood perfusion-based model for characterizing the temperature fluctuation in living tissues
    Deng, ZS
    Liu, J
    [J]. PHYSICA A-STATISTICAL MECHANICS AND ITS APPLICATIONS, 2001, 300 (3-4) : 521 - 530