Direct-drive low-speed wind energy conversion system incorporating axial-type permanent magnet generator and Z-source inverter with sensorless maximum power point tracking controller

被引:34
作者
Ramasamy, Bharani Kumar [1 ]
Palaniappan, Aravindan [2 ]
Yakoh, Sanavullah Mohamed [2 ]
机构
[1] Anna Univ, Bannari Amman Inst Technol, Dept Elect & Elect Engn, Madras 600025, Tamil Nadu, India
[2] Anna Univ, KS Rangasamy Coll Technol, Dept Elect & Elect Engn, Madras 600025, Tamil Nadu, India
关键词
SCHEME; DESIGN;
D O I
10.1049/iet-rpg.2012.0248
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With the ever increasing concern on environmental pollution and energy crisis, generation of power from wind is developing very fast. In the proposed wind energy conversion system (WECS), a variable-speed wind turbine, axial-type permanent magnet generator (PMG), Z-source inverter (ZSI) and sensorless maximum power point tracking (MPPT) controller are included. Although the conventional-type induction generator has the advantage of robust construction and maintenance-free operation, it has drawbacks like low-power factor and need for an ac excitation source which is overcome by the PMG. To obtain fixed voltage and frequency, PMG-generated voltage is fed to power converters. Conventionally the three stages of power conversion consist of rectifier, boost chopper and pulse-width-modulated inverter which reduce the efficiency, power quality and reliability of the overall WECS. To overcome these barriers of conventional system a two-stage-based direct-drive WECS is proposed. The maximum power point for each speed is traced using sensorless MPPT controller, which estimates the rotor speed, by using a simple sensorless speed estimator which is given as the input to the MPPT controller. The proposed sensorless MPPT controller for direct-drive WECS along with the ZSI is simulated in MATLAB/SIMULINK and the results are compared with experimental setup.
引用
收藏
页码:284 / 295
页数:12
相关论文
共 14 条
[1]   A Novel Scheme for Rapid Tracking of Maximum Power Point in Wind Energy Generation Systems [J].
Agarwal, Vivek ;
Aggarwal, Rakesh K. ;
Patidar, Pravin ;
Patki, Chetan .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2010, 25 (01) :228-236
[2]  
[Anonymous], IEEE COMP SOC C COMP
[3]  
Barakati SM, 2005, IEEE POWER ENG SOC, P2083
[4]   A method of tracking the peak power points for a variable speed wind energy conversion system [J].
Datta, R ;
Ranganathan, VT .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2003, 18 (01) :163-168
[5]  
Femandez-Comesana P., 2010, 2010 IEEE INT S IND, P2946
[6]   A rule-based fuzzy logic controller for a PWM inverter in a stand alone wind energy conversion scheme [J].
Hilloowala, RM ;
Sharaf, AM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (01) :57-65
[7]   Maximum power point tracker of wind energy conversion system [J].
Kesraoui, M. ;
Korichi, N. ;
Belkadi, A. .
RENEWABLE ENERGY, 2011, 36 (10) :2655-2662
[8]   Design optimization and site matching of direct-drive permanent magnet wind power generator systems [J].
Li, H. ;
Chen, Z. .
RENEWABLE ENERGY, 2009, 34 (04) :1175-1184
[9]   Z-source inverter [J].
Peng, FZ .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (02) :504-510
[10]   Steady-State Analysis and Designing Impedance Network of Z-Source Inverters [J].
Rajakaruna, Sumedha ;
Jayawickrama, Laksumana .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (07) :2483-2491