Performance of dielectric barrier discharge ionization mass spectrometry for pesticide testing: a comparison with atmospheric pressure chemical ionization and electrospray ionization

被引:37
作者
Gilbert-Lopez, Bienvenida [3 ]
Geltenpoth, Helma [3 ]
Meyer, Cordula [3 ]
Michels, Antje [3 ]
Hayen, Heiko [2 ]
Molina-Diaz, Antonio [1 ]
Garcia-Reyes, Juan F. [1 ]
Franzke, Joachim [3 ]
机构
[1] Univ Jaen, Analyt Chem Res Grp FQM 323, Dept Phys & Analyt Chem, Jaen 23071, Spain
[2] Univ Wuppertal, Dept Food Chem, D-42119 Wuppertal, Germany
[3] Leibniz Inst Analyt Wissensch ISAS eV, D-44227 Dortmund, Germany
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; LC-MS; MULTIMODE SOURCE; FOOD; PHOTOIONIZATION; RESIDUES; MS/MS; ELECTROCHEMISTRY;
D O I
10.1002/rcm.6469
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE The present study reports on the evaluation of dielectric barrier discharge microplasma ionization (DBDI) for liquid chromatography/high resolution mass spectrometry (LC/HRMS) analyses of pesticide residues in fruit and vegetables. Ionization, fragmentation, analytical performance and matrix effects displayed by LC/DBDI-MS were critically evaluated and compared with both atmospheric pressure chemical ionization (APCI) and electrospray (ESI), using a set of over 40 representative multiclass pesticides. METHODS Sample preparation was accomplished using standard QuEChERS procedure and the identification and quantitation of the pesticides tested accomplished by means of LC/MS with a hybrid linear quadrupole ion trap (LIT)-Fourier transform ion cyclotron resonance (FTICR) mass spectrometer operated in full-scan positive ion mode using DBDI, APCI and ESI sources. RESULTS The developed LC/DBDI-MS method allowed the screening of 43 pesticides in three different vegetable matrices: apple, orange and tomato. Minor matrix effects (i.e. signal suppression or enhancement =20%) were observed in most of the studied compounds: 95%, 70% and 81% of the studied compounds showed minor matrix effects in extracts of apple, orange and tomato, respectively. The results of the analysis of spiked orange extracts showed that the sensitivity obtained with LC/DBDI-MS is appropriate for multi-residue analysis of pesticide residues in fruit and vegetable samples. The limits of quantitation (LOQs) obtained for most of the studied pesticides were in compliance with the European Regulation 396/2005 (and subsequent updates) on food commodities (default maximum residue level of 10 mu g kg1). CONCLUSIONS Comparative studies with commercial sources demonstrate the suitability of DBDI as an ionization technique for residue analysis, because of the combination of the following two advantages: (1) the use of DBDI provides minimized matrix effects compared with APCI, and (2) improved the detection in terms of sensitivity of selected compounds that are not easily ionized by ESI, such as parathion. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:419 / 429
页数:11
相关论文
共 40 条
[1]   Comparison of automated on-line solid-phase extraction followed by liquid chromatography mass spectrometry with atmospheric pressure chemical ionization and particle beam mass spectrometry for the determination of a priority group of pesticides in environmental waters [J].
Aguilar, C ;
Ferrer, I ;
Borrull, F ;
Marcé, RM ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :147-163
[2]   Residue analysis of 500 high priority pesticides: Better by GC-MS or LC-MS/MS? [J].
Alder, Lutz ;
Greulich, Kerstin ;
Kempe, Guenther ;
Vieth, Barbel .
MASS SPECTROMETRY REVIEWS, 2006, 25 (06) :838-865
[3]  
Anastassiades M, 2003, J AOAC INT, V86, P412
[4]   From fundamentals to applications: recent developments in atmospheric pressure photoionization mass spectrometry [J].
Bos, SJ ;
van Leeuwen, SM ;
Karst, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (01) :85-99
[5]   Advanced liquid chromatography-mass spectrometry interface based on electron ionization [J].
Cappiello, A. ;
Famiglini, G. ;
Pierini, E. ;
Palma, P. ;
Trufelli, H. .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5364-5372
[6]   Electron ionization for LC/MS [J].
Cappiello, A ;
Famiglini, G ;
Palma, P .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :496A-503A
[7]   Relating electrospray ionization response to nonpolar character of small peptides [J].
Cech, NB ;
Enke, CG .
ANALYTICAL CHEMISTRY, 2000, 72 (13) :2717-2723
[8]   Atmospheric-pressure laser ionization:: a novel ionization method for liquid chromatography/mass spectrometry [J].
Constapel, M ;
Schellenträger, M ;
Schmitz, OJ ;
Gäb, S ;
Brockmann, KJ ;
Giese, R ;
Benter, T .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (03) :326-336
[9]   Liquid chromatography with post-column electrochemical treatment and mass spectrometric detection of non-polar compounds [J].
Diehl, G ;
Liesener, A ;
Karst, U .
ANALYST, 2001, 126 (03) :288-290
[10]   On-line electrochemistry - MS and related techniques [J].
Diehl, G ;
Karst, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) :390-398