Intra- and Interobserver Variability of Aortic Aneurysm Volume Measurement With Fast CTA Postprocessing Software

被引:74
作者
van Prehn, Joffrey [1 ]
van der Wal, Martijn B. A. [1 ]
Vincken, Koen [2 ]
Bartels, Lambertus W. [2 ]
Moll, Frans L. [1 ]
van Herwaarden, Joost A. [1 ]
机构
[1] Univ Med Ctr, Dept Vasc Surg, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
关键词
endovascular aneurysm repair; abdominal aortic aneurysm; computed tomographic angiography; aneurysm sac volume; volumetry; observer variability;
D O I
10.1583/08-2478.1
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To study inter- and intraobserver variability of volume measurements with anew, fast semi-automatic method and compare the results to a previously validated standard manual method for volume measurement. Methods: Twenty abdominal computed tomographic angiography (CTA) datasets of patients with abdominal aortic aneurysms undergoing endovascular aneurysm repair (EVAR) were randomly selected from a clinical database (10 pre and 10 post EVAR). Aneurysm sac volume was measured by 2 independent observers using both the standard and semi-automatic methods. Intra- and interobserver variabilities and variability between the 2 methods were studied. Differences of each pair of measurements were plotted against their mean, and the repeatability coefficient (RC) was calculated according to Bland and Altman. Results: For the standard method, the intraobserver mean difference was 0.9 mL (0.4% of the first measurement), with an FIC of 8.4 mL (4.2%); the interobserver mean difference was 0.0 mL (0.0%), with a RIC of 11.8 mL (5.9%). For the semi-automatic method, the intraobserver mean difference was 1.4 mL (0.7%), with an RIC of 7.8 mL (4.1%); the interobserver mean difference was -1.8 mL (-1.0%), with an RIC of 10.8 mL (5.7%). The mean difference between the methods was 8.3 mL (4.2%), with an RIC of 25.1 mL (12.6%) for observer 1, and a mean difference of 6.4 mL (3.2%) and an IRC of 21.3 mL (10.7%) for observer 2. Conclusion:The semi-automatic method showed good intra- and interobserver variability for volume measurements of aortic aneurysms before and after EVAR. Volume measurements with the semi-automatic method correspond to measurements with the standard method. Sophisticated and fast postprocessing software may facilitate acceptance and clinical application of volume measurements in daily practice. The cutoff of 5% for relevant volume changes during follow-up, as advised in the reporting standards for EVAR, is sustained.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 14 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   The efficacy of transfemoral endovascular aneurysm management: A study on size changes of the abdominal aorta during mid-term follow-up [J].
Broeders, IAMJ ;
Blankensteijn, JD ;
Gvakharia, A ;
May, J ;
Bell, PRF ;
Swedenborg, J ;
Collin, J ;
Eikelboom, BC .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 14 (02) :84-90
[3]   Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair [J].
Chaikof, EL ;
Fillinger, MF ;
Matsumura, JS ;
Rutherford, RB ;
White, GH ;
Blankensteijn, JD ;
Bernhard, VM ;
Harris, PL ;
Kent, KC ;
May, J ;
Veith, FJ ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (05) :1061-1066
[4]   First experience in human beings with a permanently implantable intrasac pressure transducer for monitoring endovascular repair of abdominal aortic aneurysms [J].
Ellozy, SH ;
Carroccio, A ;
Lookstein, RA ;
Minor, ME ;
Sheahan, CM ;
Juta, J ;
Cha, A ;
Valenzuela, R ;
Addis, MD ;
Jacobs, MS ;
Teodorescu, VJ ;
Marin, ML .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) :405-411
[5]   Three-dimensional analysis of enlarging aneurysms after endovascular abdominal aortic aneurysm repair in the Gore Excluder Pivotal clinical trial [J].
Fillinger, M .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (05) :888-895
[6]  
Fillinger M F, 1999, Semin Vasc Surg, V12, P327
[7]  
Powell JT, 1998, LANCET, V352, P1649
[8]   Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison [J].
Prinssen, M ;
Verhoeven, ELG ;
Verhagen, HJM ;
Blankensteijn, JD .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2003, 26 (02) :184-187
[9]   Long-term fate of the aneurysmal sac after endoluminal exclusion of abdominal aortic aneurysms [J].
Rhee, RY ;
Eskandari, MK ;
Zajko, AB ;
Makaroun, MS .
JOURNAL OF VASCULAR SURGERY, 2000, 32 (04) :689-695
[10]   Inter- and intraobserver variability of CT measurements obtained after endovascular repair of abdominal aortic aneurysms [J].
Wever, JJ ;
Blankensteijn, JD ;
van Rijn, JC ;
Broeders, IAMJ ;
Eikelboom, BC ;
Mali, WPTM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) :1279-1282