Accuracy of digital and analogue cephalometric measurements assessed with the sandwich technique

被引:57
作者
Santoro, M [1 ]
Jarjoura, K [1 ]
Cangialosi, TJ [1 ]
机构
[1] Columbia Univ, Div Orthodont, Sch Dent & Oral Surg, New York, NY 10032 USA
关键词
D O I
10.1016/j.ajodo.2005.12.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of the study was to evaluate the accuracy of cephalometric measurements obtained with digital tracing software compared with equivalent hand-traced measurements. In the sandwich technique, a storage phosphor plate and a conventional radiographic film are placed in the same cassette and exposed simultaneously. The method eliminates positioning errors and potential differences associated with multiple radiographic exposures that affected previous studies. It was used to ensure the equivalence of the digital images to the hard copy radiographs. Cephalometric measurements instead of landmarks were the focus of this investigation in order to acquire data with direct clinical applications. Methods: The sample consisted of digital and analog radiographic images from 47 patients after orthodontic treatment. Nine cephalometric landmarks were identified and 13 measurements calculated by 1 operator, both manually and with digital tracing software. Measurement error was assessed for each method by duplicating measurements of 25 randomly selected radiographs and by using Pearson's correlation coefficient. A paired t test was used to detect differences between the manual and digital methods. Results: An overall greater variability in the digital cephalometric measurements was found. Differences between the 2 methods for SNA, ANB, S-Go:N-Me, U1/L1, L1-GoGn, and N-ANS:ANS-Me were statistically significant (P < .05). However, only the U1/L1 and S-Go:N-Me measurements showed differences greater than 2 SE (P < .0001). Conclusions: The 2 tracing methods provide similar clinical results; therefore, efficient digital cephalometric software can be reliably chosen as a routine diagnostic tool. The user-friendly sandwich technique was effective as an option for interoffice communications.
引用
收藏
页码:345 / 351
页数:7
相关论文
共 24 条
[1]   RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[2]   RELIABILITY OF HEAD FILM MEASUREMENTS .2. CONVENTIONAL ANGULAR AND LINEAR MEASURES [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (05) :505-&
[3]  
Chen YJ, 2000, ANGLE ORTHOD, V70, P387
[4]  
Chen YJ, 2004, ANGLE ORTHOD, V74, P155
[5]   Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique [J].
Geelen, W ;
Wenzel, A ;
Gotfredsen, E ;
Kruger, M ;
Hansson, LG .
EUROPEAN JOURNAL OF ORTHODONTICS, 1998, 20 (03) :331-340
[6]   Diagnostic yield of conventional and digital cephalometric images: a human cadaver study [J].
Gijbels, F ;
Serhal, CB ;
Willems, G ;
Bosmans, H ;
Sanderink, G ;
Persoons, M ;
Jacobs, R .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (02) :101-105
[7]  
Gravely J F, 1974, Br J Orthod, V1, P95
[8]   Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilmsProspektive Studie zur Reproduzierbarkelt von Referenzpunkten in konventionellen und digitalen seitlichen Fernröntgenaufnahmen [J].
Kai Hagemann ;
Dirk Vollmer ;
Thomas Niegel ;
Ulrike Ehmer ;
Irmela Reuter .
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2000, 61 (2) :91-99
[9]   Cephalometric digitization: A determination of the minimum scanner settings necessary for precise landmark identification [J].
Held, CL ;
Ferguson, DJ ;
Gallo, MW .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (05) :472-481
[10]   THE ANALYSIS OF ERRORS IN ORTHODONTIC MEASUREMENTS [J].
HOUSTON, WJB .